Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
101 | 4 | To set which report need to be sent. | 8 | Report Accumulated kWh | |
2 | Report Instantaneous Current (Amperes) | ||||
4 (Default) |
Report Instantaneous Watts | ||||
1 | Report Instantaneous Voltage | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
102 | 4 | To set which report need to be sent. | 1 | Report Instantaneous Voltage | |
4 | Report Instantaneous Watts | ||||
8 (Default) |
Report Accumulated kWh | ||||
2 | Report Instantaneous Current (Amperes) | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
103 | 4 | To set which report need to be sent. | 1 | Report Instantaneous Voltage | |
2 | Report Instantaneous Current (Amperes) | ||||
4 | Report Instantaneous Watts | ||||
8 | Report Accumulated kWh | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
111 | 4 | Set the interval time of sending report. | 0 to 268435456 (Default) |
Interval Seconds | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
112 | 4 | Set the interval time of sending report. | 0 to 268435456 (Default) |
Interval Seconds | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
113 | 4 | Set the interval time of sending report. | 0 to 268435456 (Default) |
Interval Seconds | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
20 | 1 | Configure the output load status after re-power on | 0 (Default) |
The output load status will be the same as the previous state before a power outage. | |
1 | The output load status will be ON state after re-power on. | ||||
2 | The output load status will be OFF state after re-power on. | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
200 | 1 | Partner ID | 0 (Default) |
Aeon Labs Standard Product | |
1 to 255 | Partner ID of Partner Product | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
252 | 1 | Enable/Disable Lock Configuration | 0 (Default) |
All configuration parameters are configurable. | |
1 | All configuration parameters are not configurable (Locked). | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
254 | 2 | Device Tag | 0 to 32767 (Default) |
Device Tag | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
255 | 4 | Reset to default factory setting | 1431655765 | Reset the product to default factory setting and be excluded from the Z-wave network. | |
1 | Resets all configuration parameters to default setting. | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
3 | 1 | Current Overload Protection | 0 (Default) |
Overload Protection Disabled | |
1 | Overload Protection is Enabled | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
33 | 4 | Change the color value of RGB LED for testing | 0 to 255 (Default) |
Reserved | |
255 to 65535 | Range of red color value. | ||||
65536 to 16777215 | Range of green color value. | ||||
16777215 to 2147483647 | Range of blue color value. | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
80 | 1 | Enable/Disable to send notifications to associated devices to associated devices. | 0 (Default) |
Send Nothing (Disabled) | |
1 | Send HAIL Command | ||||
2 | Send BASIC Report Command | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
81 | 1 | Configure the state of LED | 0 (Default) |
The state of LED will follow with the output load state(Energy mode) | |
1 | The state of LED will follow with the output load state, but will turn off after 5 seconds if there is no any switch action.(Momentary indicate mode) | ||||
2 | The state of LED will the same with Night light mode state configured by parameter 83. | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
83 | 4 | Configure the LED indication status when it is in Night light mode | 0 to 255 | Set the indication value of red Led. | |
256 to 65535 | Set the indication value of green Led. | ||||
65536 to 16777215 (Default) |
Set the indication value of blue Led. | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
84 | 1 | Configure the brightness level for the LED indication | 0 to 100 (Default) |
Brightness level range is 0 to 100%. | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
90 | 1 | Enable/Disable the function of parameter 91 and 92. | 0 | Configuration Parameters 91 and 92 are Disabled | |
1 (Default) |
Configuration Parameters 91 and 92 are Enabled | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
91 | 2 | Induce an automatic report | 0 to 32767 (Default) |
The threshold can be set from 0 to 32767 watt. | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
92 | 1 | Induce an automatic report | 0 to 100 (Default) |
The threshold can be set from 0 to 100 percent. | |