Product Recognition | |
|---|
Certification Number | ZC10-18015970 |
|---|
Name | PIR Motion Sensor |
|---|
Short Description | AXIS T8341 PIR Motion Sensor is a wireless sensor which provides motion detection both day and night. |
|---|
Long Description | AXIS T8341 PIR Motion Sensor is a wireless sensor which provides motion detection both day and night. With its support for wireless input/output connectivity, the PIR motion sensor can communicate wirelessly with AXIS M5065 PTZ Network camera or other connected Z-Wave Plus® controllers, creating a small security solution with less cabling. Thanks to its integrated wireless I/O connectivity, AXIS T8341 enables flexible installation as the sensor can easily be moved and adapted to your needs. |
|---|
Brand | Axis Communications |
|---|
Product Identifier | T8341-JP |
|---|
OEM Version | HW: 1 FW: 1.01:00.05 |
|---|
Hardware Platform | SD3502 |
|---|
Z-Wave Version | 6.71.01 |
|---|
Library Type | SLAVE_ENHANCED_232 |
|---|
Device Type | Notification Sensor |
|---|
Role Type | ROLE_TYPE_SLAVE_SLEEPING_REPORTING |
|---|
Manufacturer ID | 0x0364 |
|---|
Product Type ID | 0x0002 |
|---|
Product ID | 0x0001 |
|---|
User Icon | 0x0C07 |
|---|
Installer Icon | 0x0C07 |
|---|
Frequency Plans | JP: 922.50MHz, 923.90MHz, 926.30MHz |
|---|
Categories | Sensors, Security Add-Ons |
|---|
Countries / Regions | Japan |
|---|
Supported Command Classes | Identifier | Name | Key | Version |
|---|
COMMAND_CLASS_FIRMWARE_UPDATE_MD_V4 | Firmware Update Meta-Data V4 | 0x7A | 4 | COMMAND_CLASS_POWERLEVEL | Powerlevel | 0x73 | 1 | COMMAND_CLASS_BATTERY | Battery | 0x80 | 1 | COMMAND_CLASS_CONFIGURATION | Configuration | 0x70 | 1 | COMMAND_CLASS_SECURITY | Security S0 | 0x98 | 1 | COMMAND_CLASS_TRANSPORT_SERVICE_V2 | Transport Service V2 | 0x55 | 2 | COMMAND_CLASS_VERSION_V2 | Version V2 | 0x86 | 2 | COMMAND_CLASS_WAKE_UP_V2 | Wake Up V2 | 0x84 | 2 | COMMAND_CLASS_DEVICE_RESET_LOCALLY | Device Reset Locally | 0x5A | 1 | COMMAND_CLASS_ZWAVEPLUS_INFO_V2 | Z-Wave Plus Info V2 | 0x5E | 2 | COMMAND_CLASS_ASSOCIATION_V2 | Association V2 | 0x85 | 2 | COMMAND_CLASS_ASSOCIATION_GRP_INFO | Association Group Info | 0x59 | 1 | COMMAND_CLASS_SECURITY_2 | Security S2 | 0x9F | 1 | COMMAND_CLASS_SUPERVISION | Supervision | 0x6C | 1 | COMMAND_CLASS_MANUFACTURER_SPECIFIC_V2 | Manufacturer Specific V2 | 0x72 | 2 | COMMAND_CLASS_NOTIFICATION_V4 | Notification V4 | 0x71 | 4 |
|
|---|
Controlled Command Classes | Identifier | Name | Key | Version |
|---|
COMMAND_CLASS_BASIC | Basic | 0x20 | 1 |
|
|---|
S2 Classes | S2_UNAUTHENTICATED, S2_AUTHENTICATED |
|---|
Documents | Category | Description | File |
|---|
Manual_Primary_Lang | Product or Owner's Manual | |
|
|---|
Features | Feature | Values |
|---|
Battery Type | | Color | | Supported Notification Types | | Battery Quantity | | Firmware Updatable | Value |
|---|
Updatable by Consumer via Internet |
|
|
|---|
Association Groups | Group Number | Maximum Nodes Supported | End Point ID | Description |
|---|
1 | 1 | 0 | Association with 1 node. | 2 | 4 | 0 | Association with 4 nodes (i.e. end devices such as smart plugs and other lighting controllers). This allows the detector to transfer commands directly to end devices without the participation of the controller. This has the effect that when the detector triggers, all devices associated with detector will be operated. |
|
|---|
Configuration Parameters | Parameter Number | Name | Description | Format | Size | Min Value | Max Value | Default Value | Parameter Values |
|---|
1 | Basic Set Level | When Basic Set Command is sent where contains a value, the receiver will take it for consideration; for instance, if a lamp module is received the Basic Set command of which value is decisive as to how bright of dim level of lamp module shall be. | 0 | 1 | 0 | 0 | 99 | From | To | Description |
|---|
1 | 99 | ON (Binary Switch Device)/Dim Level (Multilevel Switch Device) |
| 3 | Sensitivity Level | In order to provide a best efficiency of the detector, it is recommended to test the detector with movements from a farthest end of the coverage area at first time of use. If movements cannot be detected sensitively, simply adjust the sensitivity level with Configuration Parameter #3. This parameter can be configured with the value of 1 through 10, where 1 means low sensitivity and 10 means highest sensitivity. | 0 | 1 | 0 | 0 | 6 | From | To | Description |
|---|
1 | 10 | Sensitivity Level |
| 4 | Re-trigger Interval Setting | The Configuration parameter that can be used to adjust the interval of being re-triggered after the detector has been triggered as Configuration Parameter #4. No response will be made during this interval if a movement is presented. The time interval can be set between 5 secs to 3600 secs. | 0 | 2 | 0 | 0 | 180 | From | To | Description |
|---|
5 | 3600 | Re-trigger Interval Setting |
|
|
|---|
Texts | ID | Description | Value |
|---|
5 | Factory Reset | Factory Reset (This procedure should only be used when the controller is inoperable.)
1. Press the tamper switch 3 times within 1.5 seconds to put the unit into exclusion mode.
2. Within 1 second of step 1, press the tamper switch again and hold until LED is off (about 5 seconds).
3. Node ID is excluded. The device reverts to 2-second on, 2-second off factory default state and will be in auto-inclusion mode for 4 minutes. | 2 | Exclusion | Manual exclusion
Note
For more details see the installation guide
1. Detach the battery cover.
2. Press the tamper switch 3 times within 1.5 seconds to put the unit into learning (inclusion/exclusion) mode.
3. The exclusion process should be completed when the LED stops blinking
4. Refit the battery cover. | 4 | Device Wake-Up | Wakeup Command Class
After it has been included into a Z-Wave network, the detector will go to sleep but will send a Wakeup
Notification Command periodically at preset period to the controller. The Motion detector will stay awake
for 10 seconds at least and then go back to sleep to conserve battery life.
The time interval between Wakeup Notification Commands can be set in the Wakeup Command Class
based on the range values below:
Minimum Wake Up Interval 600s (10 minutes)
Maximum Wake Up Interval 86400s (1 day)
Default Wake Up Interval 14400s (4 hours)
Wake Up Interval Step Seconds 600s (10 minutes) | 6 | Additional Special Features | The user can set a detecting percentage of lux level which determines when the light sensor will be activated. If percentage of lux level of ambient illumination falls below this percentage, and a person moves across or within the protected area, the detector will emit Z-Wave ON Command (i.e. Basic Set Command (Value = Basic Set Level)) to controller and activate connected modules and lighting. Percentage can be set between 1% to 100%. | 1 | Inclusion | Auto inclusion
The motion sensor supports the auto inclusion feature where it will automatically enter Inclusion mode when first powered up.
This will also apply when powered up after a factory reset.
1. Use a screwdriver to detach the rear cover.
2. Put the AXIS M6505 camera (Z-Wave controller) into inclusion mode.
3. Insert 1 CR123 3V batteries into the battery compartment with the correct polarity. The LED on the device should turn ON
4. The inclusion process should be completed when the LED stops blinking
5. Perform test before you refit the rear cover.
Manual inclusion
You can also choose to manually add the Z-Wave device to a control device. Please follow the steps described below.
Note
For best results, exclude the device before starting the inclusion process. For more details see the installation guide
1. Press the tamper switch 3 times within 1.5 seconds to put the unit into learning (inclusion/exclusion) mode.
2. The inclusion process should be completed when the LED stops blinking
3. Perform a test before you refit the cover. |
|
|---|
Supported Notification Types | Notification Type | Event / State |
|---|
Home Security | (Refer to parameters): State idle |
|
|---|
Supports NWI | Yes |
|---|
Supports Explorer Frames | Yes |
|---|
Radio Range Z-Wave (m) | 40 |
|---|