3 | Overload safety switch | This function allows to turn off the controlled device in case of exceeding the defined power. Controlled device can be turned back on via button or sending a control frame. By default this function is inactive. | 0 | 2 | 0 | 0 | 0 | From | To | Description |
|---|
10 | 18000 | 1.0-1800.0W, step 0.1W) - power threshold | 0 | 0 | function inactive |
|
23 | Controlling „On/Off (Power)” association group (3) | This parameter defines the way that 3rd association group devices are controlled. Depends on the actual measured power (according to parameters 21 and 22 settings). | 0 | 1 | 0 | 0 | 3 | From | To | Description |
|---|
1 | 1 | send frame (with value set in parameter 26) only if power exceeded value of parameter 21 | 2 | 2 | send frame (with value set in parameter 27) only if power dropped below value of parameter 22 | 3 | 3 | send frame in both cases |
|
31 | Response to alarm frames | This parameter defines how the Wall Plug will respond to alarms (device’s status change). In case of values 1 or 2 the Wall Plug is operating normally and LED frame signals an alarm through time defined in parameter 32 or until the alarm is canceled. In case of values 5 to 50 the Wall Plug does not report status change, power changes, ignores BASIC SET command frames. After time defined in parameter 32 or after the alarm cancellation, connected device is set to the previous state. | 0 | 1 | 0 | 0 | 0 | From | To | Description |
|---|
0 | 0 | no reaction | 1 | 1 | turn connected device on | 2 | 2 | turn connected device off | 5 | 50 | (0.5-5.0s, step 0.1s) - cyclically change device state with set period |
|
41 | LED frame color when controlled device is on | When set to 1 or 2, LED frame color will change depending on active power and parameter 40. Other colors are set permanently and do not depend on power consumption. | 0 | 1 | 0 | 0 | 1 | From | To | Description |
|---|
0 | 0 | illumination turned off completely | 1 | 1 | color changes smoothly depending on active power | 2 | 2 | color changes in steps depending on active power | 3 | 3 | white | 4 | 4 | red | 5 | 5 | green | 6 | 6 | blue | 7 | 7 | yellow | 8 | 8 | cyan | 9 | 9 | magenta |
|
42 | LED frame color when controlled device is off | This parameter defines the illumination color after turning off. | 0 | 1 | 0 | 0 | 0 | From | To | Description |
|---|
0 | 0 | illumination turned off completely | 1 | 1 | LED frame is illuminated with a color corresponding to the last measured power, before the controlled device was turned off | 3 | 3 | white | 4 | 4 | red | 5 | 5 | green | 6 | 6 | blue | 7 | 7 | yellow | 8 | 8 | cyan | 9 | 9 | magenta |
|
43 | LED frame color at the Z-Wave network alarm detection | This parameter defines the illumination color in case of Z-Wave alarm. | 0 | 1 | 0 | 0 | 2 | From | To | Description |
|---|
0 | 0 | illumination turned off completely | 1 | 1 | no change in color. LED frame color is determined by settings of parameters 41 or 42 | 2 | 2 | LED frame flashes red/blue/white | 3 | 3 | white | 4 | 4 | red | 5 | 5 | green | 6 | 6 | blue | 7 | 7 | yellow | 8 | 8 | cyan | 9 | 9 | magenta |
|
2 | Remember device status before the power failure | This parameter determines how the Wall Plug will react in the event of power supply failure (e.g. power outage or taking out from the electrical outlet). After the power supply is back on, the Wall Plug can be restored to previous state or remain switched off. | 0 | 1 | 0 | 0 | 1 | From | To | Description |
|---|
0 | 0 | device remains switched off | 1 | 1 | device restores the state from before the power failure |
|
24 | SWITCH ON value - „On/Off (Button)” association group (2) | The value of BASIC SET command frame sent to the devices associated in 2nd group „On/Off (Button)” when turning the device ON using the button. | 0 | 2 | 0 | 0 | 255 | From | To | Description |
|---|
0 | 0 | turning off associated devices | 1 | 99 | forcing level of associated devices | 255 | 255 | setting associated devices to the last remembered state or turning them on |
|
25 | SWITCH OFF value - „On/Off (Button)” association group (2) | The value of BASIC SET command frame sent to the devices associated in 2nd group „On/Off (Button)” when turning the device OFF using the button. | 0 | 1 | 0 | 0 | 0 | From | To | Description |
|---|
0 | 0 | turning off associated devices | 1 | 99 | forcing level of associated devices | 255 | 255 | setting associated devices to the last remembered state or turning them on |
|