Product Recognition | |
|---|
Certification Number | ZC10-18056119 |
|---|
Name | Water Leak Sensor |
|---|
Short Description | Water Sensor is a wireless water leak sensor |
|---|
Long Description | ✓ It alerts you with a built-in siren when water is detected
✓ Low voltage alarm to remind changing battery
✓ Easy to set up and use
✓ Universally applicable: universally applicable in every place and circumstances. |
|---|
Brand | Aibase |
|---|
Product Identifier | HA-ZW-5SF |
|---|
OEM Version | HW: 1 FW: 1.09 |
|---|
Hardware Platform | ZM5101 |
|---|
Z-Wave Version | 6.71.01 |
|---|
Library Type | SLAVE_ENHANCED_232 |
|---|
Device Type | Notification Sensor |
|---|
Role Type | ROLE_TYPE_SLAVE_SLEEPING_REPORTING |
|---|
Manufacturer ID | 0x0384 |
|---|
Product Type ID | 0x0200 |
|---|
Product ID | 0x000a |
|---|
User Icon | 0x0c05 |
|---|
Installer Icon | 0x0c05 |
|---|
Frequency Plans | US: 916.00MHz, 908.40MHz |
|---|
Categories | Sensors |
|---|
Countries / Regions | United States of America |
|---|
Supported Command Classes | Identifier | Name | Key | Version |
|---|
COMMAND_CLASS_FIRMWARE_UPDATE_MD_V4 | Firmware Update Meta-Data V4 | 0x7A | 4 | COMMAND_CLASS_POWERLEVEL | Powerlevel | 0x73 | 1 | COMMAND_CLASS_BATTERY | Battery | 0x80 | 1 | COMMAND_CLASS_CONFIGURATION | Configuration | 0x70 | 1 | COMMAND_CLASS_SECURITY | Security S0 | 0x98 | 1 | COMMAND_CLASS_TRANSPORT_SERVICE_V2 | Transport Service V2 | 0x55 | 2 | COMMAND_CLASS_VERSION_V2 | Version V2 | 0x86 | 2 | COMMAND_CLASS_WAKE_UP_V2 | Wake Up V2 | 0x84 | 2 | COMMAND_CLASS_DEVICE_RESET_LOCALLY | Device Reset Locally | 0x5A | 1 | COMMAND_CLASS_ZWAVEPLUS_INFO_V2 | Z-Wave Plus Info V2 | 0x5E | 2 | COMMAND_CLASS_ASSOCIATION_V2 | Association V2 | 0x85 | 2 | COMMAND_CLASS_ASSOCIATION_GRP_INFO | Association Group Info | 0x59 | 1 | COMMAND_CLASS_SECURITY_2 | Security S2 | 0x9F | 1 | COMMAND_CLASS_SUPERVISION | Supervision | 0x6C | 1 | COMMAND_CLASS_MANUFACTURER_SPECIFIC_V2 | Manufacturer Specific V2 | 0x72 | 2 | COMMAND_CLASS_NOTIFICATION_V4 | Notification V4 | 0x71 | 4 |
|
|---|
Controlled Command Classes | Identifier | Name | Key | Version |
|---|
COMMAND_CLASS_BASIC | Basic | 0x20 | 1 |
|
|---|
S2 Classes | S2_UNAUTHENTICATED |
|---|
Documents | Category | Description | File |
|---|
Manual_Primary_Lang | Product or Owner's Manual | |
|
|---|
Features | Feature | Values |
|---|
Battery Quantity | | Supported Notification Types | | Battery Type | | Firmware Updatable | Value |
|---|
Updatable by Consumer by RF |
| Sensors | |
|
|---|
Association Groups | Group Number | Maximum Nodes Supported | End Point ID | Description |
|---|
2 | 5 | 0 | 1.Basic Set
Sensor will send Basic Set when the water probe is triggered.
| 1 | 5 | 0 | Z-Wave Plus Lifeline
1. Notification Report.
Sensor will send Notification Report when the water probe is triggered.
2. Battery Report.
Sensor will send Battery Report when the battery level is low and the battery report’s value is 0xFF.
3. Device Reset Locally.
|
|
|---|
Configuration Parameters | Parameter Number | Name | Description | Format | Size | Min Value | Max Value | Default Value | Parameter Values |
|---|
11 | Beeping rate | beeping rate when the water probe is triggered | 0 | 1 | 0 | 0 | 0 | From | To | Description |
|---|
2 | 2 | buzzer keep on beeping always | 1 | 1 | buzzer keep on 0.5s, off 0.5s | 0 | 0 | buzzer keep on 1s, off 1s | 3 | 3 | buzzer keep silence |
| 254 | Lock/unlock all configuration parameters. | Lock/unlock all configuration parameters. | 0 | 1 | 0 | 0 | 0 | From | To | Description |
|---|
0 | 0 | unlock | 1 | 1 | lock |
| 10 | Level of low battery | This parameter defines a battery level as the “low battery”. | 0 | 1 | 0 | 0 | 10 | From | To | Description |
|---|
10 | 50 | when the battery level is less than this value, device will send low battery report to the gateway |
|
|
|---|
Texts | ID | Description | Value |
|---|
5 | Factory Reset | Pressing and holding the z-button for 5 seconds, LED will blink for 5 seconds and then keep solid for 3 seconds, after that Water Leak Sensor will send “Device_Reset_Locally” to the main controller and exclude from the Z-Wave network.
Use this procedure only in the event that the network primary controller is missing or otherwise inoperable. | 1 | Inclusion | 1. Insert the battery.
2. Set the Z-Wave network main controller into Inclusion mode.
3. Triggering this button action.
4. If the add for inclusion is successful, the LED will blink fast and then keep on 3 seconds. Otherwise, the LED will blink 25 seconds and then turn off, in which case you need to repeat the process from step 2. | 2 | Exclusion | 1. Insert the battery.
2. Set the Z-Wave network main controller into exclusion mode.
3. Triggering this button action.
If the remove for exclusion is successful, the LED will blink fast and turn off. Otherwise, the LED will keep solid for 25 seconds and then turn off, in which case you need to repeat the process from step 2. | 4 | Device Wake-Up | Short press the z-button 3 times within 1 second.
LED will blink once, and Sensor will send wake up notification to wake the device up. |
|
|---|
Supported Notification Types | Notification Type | Event / State |
|---|
Water Alarm | (Refer to parameters): State idle |
|
|---|
Supported Multilevel Sensors | Multilevel Sensor Type |
|---|
Water flow |
|
|---|
Supports NWI | Yes |
|---|
Supports Explorer Frames | Yes |
|---|
Radio Range Z-Wave (m) | 40 |
|---|