Product Recognition | |
|---|
Certification Number | ZC10-18116318 |
|---|
Name | ABUS Z-Wave Magnetic Contact |
|---|
Short Description | The ABUS Z-Wave Magnetic contact detects when windows and doors are opened and notifies your Z-Wave gateway. |
|---|
Long Description | The ABUS Z-Wave Magnetic contact detects when windows and doors are opened and notifies your Z-Wave gateway. Thanks to battery operation and adhesive mounting pad the installation it can be installed quickly and simple. The Magnetic contact is protected against sabotage via a tamper switch. Battery life is up to 3 years. |
|---|
Brand | ABUS |
|---|
Product Identifier | SHMK10000 |
|---|
OEM Version | HW: 255 FW: 3.01 |
|---|
Hardware Platform | ZM5101 |
|---|
Z-Wave Version | 6.71.03 |
|---|
Library Type | SLAVE_ROUTING |
|---|
Device Type | Notification Sensor |
|---|
Role Type | ROLE_TYPE_SLAVE_SLEEPING_REPORTING |
|---|
Manufacturer ID | 0x0403 |
|---|
Product Type ID | 0x0002 |
|---|
Product ID | 0x0000 |
|---|
User Icon | 0x0C06 |
|---|
Installer Icon | 0x0C06 |
|---|
Frequency Plans | EU: 869.85MHz, 868.40MHz |
|---|
Categories | Sensors |
|---|
Countries / Regions | European Union |
|---|
Supported Command Classes | Identifier | Name | Key | Version |
|---|
COMMAND_CLASS_POWERLEVEL | Powerlevel | 0x73 | 1 | COMMAND_CLASS_MULTI_CHANNEL_ASSOCIATION_V3 | Multi-Channel Association V3 | 0x8E | 3 | COMMAND_CLASS_BATTERY | Battery | 0x80 | 1 | COMMAND_CLASS_TRANSPORT_SERVICE_V2 | Transport Service V2 | 0x55 | 2 | COMMAND_CLASS_WAKE_UP_V2 | Wake Up V2 | 0x84 | 2 | COMMAND_CLASS_DEVICE_RESET_LOCALLY | Device Reset Locally | 0x5A | 1 | COMMAND_CLASS_ZWAVEPLUS_INFO_V2 | Z-Wave Plus Info V2 | 0x5E | 2 | COMMAND_CLASS_ASSOCIATION_V2 | Association V2 | 0x85 | 2 | COMMAND_CLASS_ASSOCIATION_GRP_INFO | Association Group Info | 0x59 | 1 | COMMAND_CLASS_NOTIFICATION_V8 | Notification V8 | 0x71 | 8 | COMMAND_CLASS_SECURITY_2 | Security S2 | 0x9F | 1 | COMMAND_CLASS_VERSION_V3 | Version V3 | 0x86 | 3 | COMMAND_CLASS_SUPERVISION | Supervision | 0x6C | 1 | COMMAND_CLASS_MANUFACTURER_SPECIFIC_V2 | Manufacturer Specific V2 | 0x72 | 2 |
|
|---|
Controlled Command Classes | Identifier | Name | Key | Version |
|---|
COMMAND_CLASS_BASIC_V2 | Basic V2 | 0x20 | 2 |
|
|---|
S2 Classes | S2_UNAUTHENTICATED |
|---|
Documents | Category | Description | File |
|---|
Manual_Primary_Lang | Product or Owner's Manual | |
|
|---|
Features | Feature | Values |
|---|
Battery Quantity | | Battery Type | | Color | | Communications Protocol | | Firmware Updatable | | Outdoor Use | | Sensors | Value |
|---|
Open/Closed (Binary) |
| Supported Notification Types | Value |
|---|
Home Security | Emergency Alarm |
|
|
|---|
Association Groups | Group Number | Maximum Nodes Supported | End Point ID | Description |
|---|
1 | 5 | 0 | Lifeline association group Include command class: Battery report, Notification report, and Device Reset Locally notification, Binary report. | 2 | 5 | 0 | Root Device group(Binary Sensor) Binary Sensor Command Class:Compatible with 300 series 1-Binary Sensor reports status of open or close door via Lifeline. 2-When the sensor detects status change between close door and open door, the device will be triggered. | 3 | 5 | 0 | Root Device group(Binary Sensor) Binary Sensor Command Class:Compatible with 300 series
1-Binary Sensor reports the removed status of door sensor.
2-When the sensor detects status change of tamper, the device will be triggered.
| 4 | 5 | 0 | Root Device group(Notification)
1-Notification report open door or close status via Lifeline.
2- When the sensor detects status change between close door and open door, the device will be triggered. | 5 | 5 | 0 | Root Device group(Notification)
1-Binary Sensor reports the removed status of door sensor.
2- When the sensor detects status change of tamper, the device will be triggered. |
|
|---|
Texts | ID | Description | Value |
|---|
4 | Device Wake-Up | - Wake up Notification is transmitted every 24 hours by default.
- Wake up Notification is transmitted after Notification Report is transmitted | 2 | Exclusion | A.) Click the - (Remove) button in your Z-Wave App and follow the further instructions.
B.) Press the Tamper-button 3 times within 1.5 seconds and the Status-LED on the base unit front will flash 3 times. The App will show if the Remove device process was successful and the Status-LED on device will flash 6 times. Repeat the exclusion process from step A if it was not successful. | 5 | Factory Reset | 1. Press the Tamper-button 3 times within 1.5 Seconds
2. The device is now restored to factory settings
Note:
1, This procedure should only be used if the primary gateway is not capable of acting.
2, If the multi-sensor is set to the factory setting, the status is set to ""not included"", the association settings and possible configurations are reset to default. | 1 | Inclusion | A.) Slide the base unit from the mounting plate and remove the safety strip from the battery compartment.
B.) Click the + (Add) button in your Z-Wave App and follow the further instructions
C.) Press the Tamper-button 3 times within 1.5 seconds and the Status-LED on the base unit front will flash 3 times. The App will show if the Add device process was successful and the Status-LED will turn off. Repeat the inclusion process from step B if it was not successful. |
|
|---|
Supported Notification Types | Notification Type | Event / State |
|---|
Home Security | (Refer to parameters): State idle | Emergency Alarm | (Refer to parameters): State idle |
|
|---|
Supported Multilevel Sensors | Multilevel Sensor Type |
|---|
General purpose |
|
|---|
Supports NWI | Yes |
|---|
Supports Explorer Frames | Yes |
|---|
Radio Range Z-Wave (m) | 40 |
|---|