1 | On/Off Status Recovery Aer Power Failure | Choose the recovery state for your Power Strip’s outlets if power outage occurs. | 0 | 1 | 0 | 0 | 0 | From | To | Description |
|---|
0 | 0 | Power Strip remembers the status for each outlet prior to power outage and turns back to it | 1 | 1 | Power Strip automatically turns ON for each outlet once power is restored (it does not remember the status prior to power outage) | 2 | 2 | Power Strip automatically turns OFF each outlet once power is restored (it does not remember the status prior to power outage) |
|
5 | Overload Protection | Set the Watt level for overload protection to kick in. The number entered as the value corresponds to the total number of Watts the Strip needs to detect across all 5 outlets to turn off automatically and send a notification to the hub. | 0 | 2 | 0 | 0 | 1800 | From | To | Description |
|---|
0 | 0 | overload protection disabled | 1 | 1800 | Watts |
|
6 | Enable/ Disable Auto Turn-Off Timer for CH1 | Use this parameter to enable or disable the auto turn-off timer for CH1 outlet. If this feature is enabled, the device connected to CH1 outlet will automatically turn off after a fixed period of time from being turned on (set in parameter 7). | 0 | 1 | 0 | 0 | 0 | From | To | Description |
|---|
0 | 0 | timer disabled | 1 | 1 | timer enabled |
|
7 | Set Auto Turn-Off Timer for CH1 | Use this parameter to set the time after which you want the device connected to CH1 outlet to automatically turn off once it has been turned on. The number entered as value corresponds to the number of minutes. | 0 | 4 | 0 | 0 | 60 | From | To | Description |
|---|
1 | 65535 | minutes |
|
8 | Enable/ Disable Auto Turn-On Timer for CH1 | Use this parameter to enable or disable the auto turn-on timer for CH1 outlet. If this feature is enabled, the device connected to CH1 outlet will automatically turn on after a fixed period of time from being turned off (set in parameter 9). | 0 | 1 | 0 | 0 | 0 | From | To | Description |
|---|
0 | 0 | timer disabled | 1 | 1 | timer enabled |
|
9 | Set Auto Turn-On Timer for CH1 | Use this parameter to set the time after which you want the device connected to CH1 outlet to automatically turn on once it has been turned off. The number entered as value corresponds to the number of minutes. | 0 | 4 | 0 | 0 | 60 | From | To | Description |
|---|
0 | 0 | | 1 | 65535 | minutes |
|
23 | Set Auto Turn-Off Timer for CH5 | Use this parameter to set the time after which you want the device connected to CH5 outlet to automatically turn off once it has been turned on. The number entered as value corresponds to the number of minutes. | 0 | 4 | 0 | 0 | 60 | From | To | Description |
|---|
1 | 65535 | minutes |
|
10 | Enable/ Disable Auto Turn-Off Timer for CH2 | Use this parameter to enable or disable the auto turn-off timer for CH2 outlet. | 0 | 1 | 0 | 0 | 0 | From | To | Description |
|---|
0 | 0 | timer disabled | 1 | 1 | timer enabled |
|
11 | Set Auto Turn-Off Timer for CH2 | Use this parameter to set the time after which you want the device connected to CH2 outlet to automatically turn off once it has been turned on. The number entered as value corresponds to the number of minutes. | 0 | 4 | 0 | 0 | 60 | From | To | Description |
|---|
1 | 65535 | minutes |
|
2 | Power Wattage Report Value Threshold | Choose how you want your Power Strip to report power consumption to your hub. The number entered as value corresponds to the number of Watts the appliance needs to go over for the change to be reported. So if 5 Watts are entered by default, the smart plug will report any change in power usage over 5 Watts for each outlet (whether it’s at least 5 Watts more or 5 Watts less compared to previous report). | 0 | 4 | 0 | 0 | 5 | From | To | Description |
|---|
0 | 0 | Power meter disabled | 1 | 65535 | Watts |
|
17 | Set Auto Turn-On Timer for CH3 | Use this parameter to set the time after which you want the device connected to CH3 outlet to automatically turn on once it has been turned off. The number entered as value corresponds to the number of minutes. | 0 | 4 | 0 | 0 | 60 | From | To | Description |
|---|
0 | 0 | | 1 | 65535 | minutes |
|
24 | Enable/ Disable Auto Turn-On Timer for CH5 | Use this parameter to enable or disable the auto turn-on timer for CH5 outlet. | 0 | 1 | 0 | 0 | 0 | From | To | Description |
|---|
0 | 0 | timer disabled | 1 | 1 | timer enabled |
|
25 | Set Auto Turn-On Timer for CH5 | Use this parameter to set the time after which you want the device connected to CH5 outlet to automatically turn on once it has been turned off. The number entered as value corresponds to the number of minutes. | 0 | 4 | 0 | 0 | 60 | From | To | Description |
|---|
1 | 65535 | minutes |
|