Product Recognition | |
|---|
Certification Number | ZC10-19036387 |
|---|
Name | Ring Panic Button |
|---|
Short Description | Ring Panic Button is an instant trigger for Ring Alarm. |
|---|
Long Description | Ring Panic Button is an instant trigger for Ring Alarm.
In case of emergency, Panic Button can be used
to signal your Ring Alarm Base Station to sound its siren. If you’re subscribed to Ring Protect Plus, our 24/7 professional monitoring center is notified and emergency responders can be dispatched. |
|---|
Brand | Ring |
|---|
Product Identifier | 4AP1S90EN0 |
|---|
OEM Version | HW: 1 FW: 10.08 |
|---|
Hardware Platform | ZM5101 |
|---|
Z-Wave Version | 6.82.03 |
|---|
Library Type | SLAVE_ENHANCED |
|---|
Device Type | Notification Sensor |
|---|
Role Type | ROLE_TYPE_SLAVE_SLEEPING_REPORTING |
|---|
Manufacturer ID | 0x0346 |
|---|
Product Type ID | 0x0801 |
|---|
Product ID | 0x0101 |
|---|
User Icon | 0x0C0A |
|---|
Installer Icon | 0x0C0A |
|---|
Frequency Plans | US: 916.00MHz, 908.40MHz |
|---|
Categories | Sensors |
|---|
Countries / Regions | United States of America |
|---|
Supported Command Classes | Identifier | Name | Key | Version |
|---|
COMMAND_CLASS_POWERLEVEL | Powerlevel | 0x73 | 1 | COMMAND_CLASS_BATTERY | Battery | 0x80 | 1 | COMMAND_CLASS_CONFIGURATION | Configuration | 0x70 | 1 | COMMAND_CLASS_TRANSPORT_SERVICE_V2 | Transport Service V2 | 0x55 | 2 | COMMAND_CLASS_WAKE_UP_V2 | Wake Up V2 | 0x84 | 2 | COMMAND_CLASS_DEVICE_RESET_LOCALLY | Device Reset Locally | 0x5A | 1 | COMMAND_CLASS_ZWAVEPLUS_INFO_V2 | Z-Wave Plus Info V2 | 0x5E | 2 | COMMAND_CLASS_ASSOCIATION_V2 | Association V2 | 0x85 | 2 | COMMAND_CLASS_ASSOCIATION_GRP_INFO | Association Group Info | 0x59 | 1 | COMMAND_CLASS_NOTIFICATION_V8 | Notification V8 | 0x71 | 8 | COMMAND_CLASS_SECURITY_2 | Security S2 | 0x9F | 1 | COMMAND_CLASS_VERSION_V3 | Version V3 | 0x86 | 3 | COMMAND_CLASS_SUPERVISION | Supervision | 0x6C | 1 | COMMAND_CLASS_MANUFACTURER_SPECIFIC_V2 | Manufacturer Specific V2 | 0x72 | 2 |
|
|---|
Controlled Command Classes | Identifier | Name | Key | Version |
|---|
COMMAND_CLASS_SUPERVISION | Supervision | 0x6C | 1 |
|
|---|
S2 Classes | S2_UNAUTHENTICATED, S2_AUTHENTICATED |
|---|
Documents | Category | Description | File |
|---|
Manual_Primary_Lang | Product or Owner's Manual | |
|
|---|
Features | Feature | Values |
|---|
Battery Quantity | | Battery Type | | Supported Notification Types | | Color | | Firmware Updatable | Value |
|---|
Updatable by Consumer by RF |
|
|
|---|
Association Groups | Group Number | Maximum Nodes Supported | End Point ID | Description |
|---|
1 | 6 | 0 | Z-Wave Plus Lifeline |
|
|---|
Configuration Parameters | Parameter Number | Name | Description | Format | Size | Min Value | Max Value | Default Value | Parameter Values |
|---|
5 | Wait time for a Supervisory Report response | The number of milliseconds waiting for a Supervisory Report response to a Supervisory Get encapsulated command from the sensor. | 0 | 2 | 0 | 0 | 1500 | From | To | Description |
|---|
500 | 5000 | Wait time for a Supervisory Report response |
| 1 | Heartbeats | Heartbeats: This parameter is the number seconds between heartbeats. Heartbeats are automatic battery reports on a timer after the last event. | 0 | 2 | 0 | 0 | 4200 | From | To | Description |
|---|
255 | 4200 | Heartbeats |
| 4 | Application Level Retry Base Wait Time Period | Application Level Retry Base Wait Time Period: The number base seconds used in the calculation for sleeping between retry messages | 0 | 1 | 0 | 0 | 6 | From | To | Description |
|---|
1 | 60 | Application Level Retry Base Wait Time Period |
| 2 | One shot timer | One shot timer: Writing to this parameter prompts the sensor to send a wakeup notification one time after this parameter's number of seconds. After which it is reset back to 0. | 0 | 2 | 0 | 0 | 0 | From | To | Description |
|---|
1 | 32767 | One shot timer |
| 3 | Number of application level retries | Number of application level retries of messages either not ACKed or messages encapsulated via supervision get that did not receive a report | 0 | 1 | 0 | 0 | 5 | From | To | Description |
|---|
0 | 5 | Number of application level retries |
|
|
|---|
Texts | ID | Description | Value |
|---|
1 | Inclusion | Inclusion Instructions -
- Begin the setup process near your Ring Alarm Base Station.
- In the Ring app, tap Set Up a Device
- Choose Security Devices, then Base Station,
then Ring Panic Button, and tap Add Device
- To complete the setup process, follow the in-app instructions.
- When prompted, scan the QR Code or enter the PIN. (The QR Code and PIN are on the back of your Panic Button and in the product packaging.)
- This begins the pairing process.
- When prompted, pull out the clear tab.
- This turns the Panic Button on. Your Base Station then finds it automatically.
- As the Panic Button pairs to your Base Station, its LED ring will blink. Once it pairs, the LED glows blue for three seconds.
Note: If the Panic Button does not pair successfully, the LED ring glows red. To try the pairing process again, remove and reinstall the battery inside the Panic Button. | 5 | Factory Reset | Factory Reset Instructions -
- Press and hold the Setup button for 10 seconds. When the LED ring stops blinking, your Panic Button has reset.
Note:
- A factory reset disconnects the Panic Button from your Ring Alarm. To begin using the Panic Button again, repeat the setup process in the Ring app.
- Use this procedure only in the event that the network primary controller is missing or otherwise inoperable. | 2 | Exclusion | Exclusion Instructions -
- Open the side menu in the Ring app and tap Devices, then Base Station. Select your Panic Button and tap the gear-shaped icon. Then tap Remove Device.
- When prompted, open the Panic Button and remove and reinstall the battery to complete the removal. | 4 | Device Wake-Up | Open top cover to wakeup device |
|
|---|
Supported Notification Types | Notification Type | Event / State |
|---|
Home Security | (Refer to parameters): State idle |
|
|---|
Supports NWI | Yes |
|---|
Supports Explorer Frames | Yes |
|---|
Supports SmartStart | Yes |
|---|
Radio Range Z-Wave (m) | 40 |
|---|