8 | Alarm Response | Enabled by (Alarm Settings), and determines what the switch does in the case an alarm is triggered. When receives any alarm enabled by Alarm Settings, Indicator Light will keep blinking based on Parameter 0x12 (18). It will prohibit user from manually or RF control the switch state until the alarm is disable. | 0 | 1 | 0 | 0 | 0 | From | To | Description |
|---|
0 | 0 | Disable, no reaction to alarm settings | 1 | 1 | Switch is ON | 2 | 2 | Switch is OFF | 3 | 3 | Switch will turn ON in 5 seconds, and then turn OFF in 5 seconds in a cycle until user disables the alarm manually |
|
9 | Alarm Settings | Determine if alarms are enabled in Switch, and what Switch will react to which alarm. The format of the parameter is Bit field (Checkboxes). The parameter MUST be treated as a bit field where each individual bit can be set or reset. A graphical configuration tool SHOULD present this parameter as a series of checkboxes. Please refer to the manual for more details about supported Notification Type and Notification Event. | 0 | 2 | 0 | 0 | 0 | From | To | Description |
|---|
256 | 256 | Smoke Alarm | 512 | 512 | CO Alarm | 1024 | 1024 | CO2 Alarm | 2048 | 2048 | Heart Alarm | 4096 | 4096 | Water Alarm | 8192 | 8192 | Access Control | 16384 | 16384 | Home Security | 1 | 1 | Access Control trigger state |
|
10 | Setting to disable alarm | Determines the method of disabling the alarm of the device. Note: Power off will also disable the alarm response without any limitation. | 0 | 2 | 0 | 0 | 0 | From | To | Description |
|---|
0 | 0 | Can be disabled by 3x tapping Action Button within 1 second | 1 | 1 | Can be disabled when receives a State Idle corresponding to the alarm. Note: If Access Control is enable, it also can be disabled when receives the reversal state of window/door. | 10 | 255 | Sets the duration of the alarm in seconds(i.e. Customer sets this setting to 50, the alarm state of the Switch will disable after 50 seconds) |
|
80 | Configure what command will be sent via Lifeline when switch state has changed. | Configure what command will be sent via Lifeline when switch state has changed. | 0 | 1 | 0 | 0 | 2 | From | To | Description |
|---|
0 | 0 | None | 1 | 1 | Basic Report | 2 | 2 | Binary Switch Report |
|
4 | Over-load protection | Define a threshold power and automatically turn off switch when the load connected bypasses the maximum allowed power regardless of always on setting. Over-load protection will be active if the load power exceeds the setting and lasts for more than 30s. If be active, Indicator Light will become red light blinking and the product will send out Notification Report (Over-load detected), and disable the function that manually or RF control the switch state until users set Protection State to be unprotected through the Gateway or Controller. Even power off will still keep Protection State. | 0 | 2 | 0 | 0 | 2415 | From | To | Description |
|---|
0 | 0 | Disable over-load protection | 1 | 2415 | Threshold power is 1-2145W |
|
81 | Load Indicator Mode setting. | Note: Configuring brightness and color of Indicator Light in different time/status of different modes will be saved in the current setting mode. Please refer to the manual for more details. | 0 | 1 | 0 | 0 | 2 | From | To | Description |
|---|
0 | 0 | Disable Mode | 1 | 1 | Night Light Mode | 2 | 2 | ON/OFF Mode |
|
82 | Configure the enable and disable time of Night Light Mode | If you want to set Night Light Mode to be enable at 19:00 at night and disable at 07:30 in the morning, you just need to configure: Value1=0x13, Value2=0x00, Value3=0x07, Value4=0x1E. | 0 | 4 | 0 | 0 | 301991936 | From | To | Description |
|---|
0 | 2147483647 | Value1=Enable Hour, Value2=Enable Minute, Value3=Disable Hour, Value4=Disabale Minute |
|
91 | Threshold Power (W) for inducing automatic report. | Threshold Power (W) for inducing automatic report. | 0 | 2 | 0 | 0 | 0 | From | To | Description |
|---|
1 | 2300 | 1-2300W | 0 | 0 | Disable |
|
92 | Threshold Power Consumption (kWh) for inducing automatic report. | Threshold Power Consumption (kWh) for inducing automatic report. | 0 | 2 | 0 | 0 | 0 | From | To | Description |
|---|
0 | 0 | Disable | 1 | 10000 | 1-10000kWh |
|
93 | Threshold Current (A) for inducing automatic report. | Threshold Current (A) for inducing automatic report. | 0 | 1 | 0 | 0 | 0 | From | To | Description |
|---|
0 | 0 | Disable | 1 | 100 | 0.1-10A. Unit is 0.1A. |
|
111 | Configure the sending frequency of Meter Report. | Configure the sending frequency of Meter Report. | 0 | 4 | 0 | 0 | 600 | From | To | Description |
|---|
0 | 0 | Disable | 600 | 2592000 | 600-2592000s. (10minute-30day) |
|
255 | Factory Reset or Initialization (Write Only) | Factory Reset or Initialization (Write Only) | 0 | 1 | 0 | 0 | 0 | From | To | Description |
|---|
0 | 0 | Initialization: Initialize all configuration parameters to default values. | 1431655765 | 1431655765 | Factory Reset: Restore the product to factory settings and remove from the network. |
|