Product Recognition | |
|---|
Certification Number | ZC10-19076681 |
|---|
Name | KONOzw Smart Hub Thermostat |
|---|
Short Description | KONOzw battery powered or 24Vac wireless thermostat |
|---|
Long Description | KONOzw is the smart hub thermostat made with you in mind. It seamlessly connects to many smart hubs and blends in or stands out with its interchangeable Décorsnap covers™. KONOzw makes it easier than ever to personalize your comfort, décor, and savings. |
|---|
Brand | LUX |
|---|
Product Identifier | KN-ZW-WH1-B04 |
|---|
OEM Version | HW: 2 FW: 1.00:00.114 |
|---|
Hardware Platform | ZM5202 |
|---|
Z-Wave Version | 6.71.03 |
|---|
Library Type | SLAVE_ENHANCED_232 |
|---|
Device Type | Thermostat - HVAC |
|---|
Role Type | ROLE_TYPE_SLAVE_ALWAYS_ON |
|---|
Manufacturer ID | 0x0411 |
|---|
Product Type ID | 0x0001 |
|---|
Product ID | 0x2111 |
|---|
User Icon | 0x1200 |
|---|
Installer Icon | 0x1200 |
|---|
Frequency Plans | US: 916.00MHz, 908.40MHz |
|---|
Categories | Thermostats, HVAC |
|---|
Countries / Regions | United States of America |
|---|
Supported Command Classes | Identifier | Name | Key | Version |
|---|
COMMAND_CLASS_POWERLEVEL | Powerlevel | 0x73 | 1 | COMMAND_CLASS_THERMOSTAT_FAN_MODE | Thermostat Fan Mode | 0x44 | 1 | COMMAND_CLASS_THERMOSTAT_OPERATING_STATE_V2 | Thermostat Operating State V2 | 0x42 | 2 | COMMAND_CLASS_PROTECTION_V2 | Protection V2 | 0x75 | 2 | COMMAND_CLASS_CLOCK | Clock | 0x81 | 1 | COMMAND_CLASS_BATTERY | Battery | 0x80 | 1 | COMMAND_CLASS_APPLICATION_STATUS | Application Status | 0x22 | 1 | COMMAND_CLASS_THERMOSTAT_FAN_STATE | Thermostat Fan State | 0x45 | 1 | COMMAND_CLASS_BASIC | Basic | 0x20 | 1 | COMMAND_CLASS_CONFIGURATION | Configuration | 0x70 | 1 | COMMAND_CLASS_SECURITY | Security S0 | 0x98 | 1 | COMMAND_CLASS_SENSOR_MULTILEVEL_V7 | Sensor Multilevel V7 | 0x31 | 7 | COMMAND_CLASS_THERMOSTAT_MODE_V2 | Thermostat Mode V2 | 0x40 | 2 | COMMAND_CLASS_THERMOSTAT_SETPOINT_V3 | Thermostat Setpoint V3 | 0x43 | 3 | COMMAND_CLASS_TRANSPORT_SERVICE_V2 | Transport Service V2 | 0x55 | 2 | COMMAND_CLASS_VERSION_V2 | Version V2 | 0x86 | 2 | COMMAND_CLASS_DEVICE_RESET_LOCALLY | Device Reset Locally | 0x5A | 1 | COMMAND_CLASS_ZWAVEPLUS_INFO_V2 | Z-Wave Plus Info V2 | 0x5E | 2 | COMMAND_CLASS_ASSOCIATION_V2 | Association V2 | 0x85 | 2 | COMMAND_CLASS_ASSOCIATION_GRP_INFO | Association Group Info | 0x59 | 1 | COMMAND_CLASS_SECURITY_2 | Security S2 | 0x9F | 1 | COMMAND_CLASS_MANUFACTURER_SPECIFIC | Manufacturer Specific | 0x72 | 1 | COMMAND_CLASS_SUPERVISION | Supervision | 0x6C | 1 | COMMAND_CLASS_FIRMWARE_UPDATE_MD_V3 | Firmware Update Meta-Data V3 | 0x7A | 3 | COMMAND_CLASS_NOTIFICATION_V4 | Notification V4 | 0x71 | 4 |
|
|---|
S2 Classes | S2_UNAUTHENTICATED, S2_AUTHENTICATED |
|---|
Documents | Category | Description | File |
|---|
Manual_Primary_Lang | Product or Owner's Manual | |
|
|---|
Features | Feature | Values |
|---|
Color | | Firmware Updatable | Value |
|---|
Updatable by Manufacturer |
| Loads Controlled | | Sensors | | Supported Notification Types | | Switch Load Capacity Current | Value |
|---|
1.5A max output rating per terminal |
| Switch Load Capacity Volt-Ampere | Value |
|---|
30VA-1.5A max output rating per terminal |
| Thermostat HVAC Systems Supported | Value |
|---|
Heat Only | Cool Only | Multi Stage | Heat Pump |
| Thermostat Power Source | Value |
|---|
Battery | Power Stealing (hard-wired 24V) |
| Battery Type | | Battery Quantity | | Thermostat Modes | Value |
|---|
Heat | Cool | Auto | Auxiliary/Emergency Heat | Fan Only | Furnace | Auto Changeover | Away |
|
|
|---|
Association Groups | Group Number | Maximum Nodes Supported | End Point ID | Description |
|---|
1 | 5 | 0 | Z-Wave Plus Lifeline |
|
|---|
Configuration Parameters | Parameter Number | Name | Format | Size | Min Value | Max Value | Default Value | Parameter Values | Description |
|---|
5 | Reversal valve Type in Heat Pump | 0 | 1 | 0 | 0 | 0 |
Warning: Undefined variable $field_object in /nas/content/live/zwaprodcatalog/wp-content/themes/hello-elementor-child/single-z-wave-product.php on line 98
From | To | Description |
|---|
0 | 0 | O-valve | 1 | 1 | B-valve |
| | 4 | System Type | 0 | 1 | 0 | 0 | 0 | From | To | Description |
|---|
0 | 0 | Furnace Gas | 1 | 1 | Furnace Electric | 2 | 2 | Heat Pump | 3 | 3 | Boiler no fan | 4 | 4 | reserved |
| | 8 | Temperature Limit - Heat Max | 0 | 2 | 0 | 0 | 90 | From | To | Description |
|---|
60 | 90 | Increment by 1F |
| | 2 | Temperature Unit (C/F) | 0 | 1 | 0 | 0 | 1 | From | To | Description |
|---|
0 | 0 | Celsius | 1 | 1 | Fahrenheit |
| Temperature Unit (C/F) | 3 | Available Control mode | 0 | 1 | 0 | 0 | 0 | From | To | Description |
|---|
0 | 0 | Heat and Cool, Auto | 1 | 1 | Heat Only | 2 | 2 | Cool Only | 3 | 3 | Heat and Cool, no Auto | 4 | 4 | reserved |
| Available Control mode | 9 | Temperature Limit - Heat Min | 0 | 2 | 0 | 0 | 45 | From | To | Description |
|---|
45 | 60 | Increment by 1F |
| | 11 | Temperature Limit - Cool Min | 0 | 2 | 0 | 0 | 50 | From | To | Description |
|---|
50 | 75 | Increment by 1F. The actual allowable range is dependent on the heat set point limit |
| | 10 | Temperature Limit - Cool Max | 0 | 2 | 0 | 0 | 95 | From | To | Description |
|---|
60 | 95 | Increment by 1F. The actual allowable range is dependent on the heat set point limit |
| | 17 | Command Echo Enable | 0 | 1 | 0 | 0 | 0 | From | To | Description |
|---|
0 | 0 | Disable | 1 | 1 | Enable |
| Command Echo for - Thermostat Mode - Thermostat Fan mode - Thermostat Setpoint | 1 | User Temperature Calibration | 0 | 2 | 0 | 0 | 0 | From | To | Description |
|---|
-250 | 250 | Step-size = 10 |
| User Temperature Calibration. For example, sending a value of +50 means the calibration offset is +0.5F |
|
|---|
Texts | ID | Description | Value |
|---|
1 | Inclusion | Initiate inclusion on your home control system using the instructions provided with it
- In HOME screen, press the knob once to enter the menu settings
-Rotate the knob to select RF icon , then press the knob to enter the inclusion/exclusion menu
-In the inclusion/exclusion menu, select ADD and press the knob to confirm
-The device will begin the adding process – you will see this screen:
Step 1: Device prepares to add to the hub
-Step 2: At the hub portal, click “Add device”
-Noted: If the hub is supporting S2 (authenticated) security mode, it will ask the user to provide the DSK code of the device to complete the inclusion process. The DSK code is printed on the product label
Input the first 5 digits in the hub portal and follow the instructions provided by the hub.
Remove the décor snap cover from the device and the product label is attached on the device front housing. There is also the same product label attached on the product gift-box.
Step 3: Device is added to the hub successfully | 2 | Exclusion | -In HOME screen, press the knob once to enter the menu settings
Rotate the knob to select , then press the knob to enter the inclusion/exclusion menu
- In the inclusion/exclusion menu, select RST and press the knob to confirm
-The device will begin the removal process – you will see this screen:
Step 1: Device prepares to be removed from the hub
-Step 2: At the hub portal, click “Remove device”.
-Step 3: Device is removed from the hub successfully.
-If the exclusion process is not successful, then HOME screen will display ER:02 to indicate the error. Press and hold the knob for over 5 seconds to return to the CONNECTION menu and retry the exclusion. | 5 | Factory Reset | Factory Reset
Note: Please use this procedure only when the network primary controller is missing or otherwise inoperable.
1. Enter the installer setting menu and select the installer option #99, then press the knob to confirm.
2. All the device parameters will be restored to factory default. The Z-Wave network setting will also be erased. User must perform the device inclusion with their hub / gateway again to re-establish the network. | 4 | Device Wake-Up | Rotate knob or send command from hub. |
|
|---|
Supported Notification Types | Notification Type | Event / State |
|---|
Power Management | (Refer to parameters): State idle |
|
|---|
Supported Multilevel Sensors | Multilevel Sensor Type |
|---|
Air temperature |
|
|---|
Supports NWI | Yes |
|---|
Supports Explorer Frames | Yes |
|---|