4 | Thermostat Power Source | The Thermostat Power Source parameter is a read-only status of the thermostat power source. | 0 | 1 | 0 | 0 | 0 | From | To | Description |
|---|
1 | 2 | 0x01 C-Wire 0x02 Batteries |
|
5 | Humidity Reporting Threshold | The Humidity Reporting Threshold parameter specifies the threshold change in the relative humidity as detected by the thermostat to trigger an unsolicited report when association reporting is enabled. | 0 | 1 | 0 | 0 | 2 | From | To | Description |
|---|
0 | 3 | 0x00 Disabled Reporting 0x01 3% Relative Humidity 0x02 5% Relative Humidity (DEFAULT) 0x03 10% Relative Humidity |
|
9 | Thermostat Recovery Mode | The Thermostat Recovery Mode parameter specifies the HVAC recovery mode type. | 0 | 1 | 0 | 0 | 2 | From | To | Description |
|---|
0 | 1 | 0x01 Fast Mode 0x02 Economy Mode (DEFAULT) |
|
10 | Temperature Reporting Filter | The Temperature Reporting Filter parameter specifes the upper and lower bounds of the ambient temperature reporting. | 0 | 4 | 0 | 0 | 0 | From | To | Description |
|---|
0 | 1 | Upper Bound Temperature Scale | 0 | 124 | Upper Bound Temperature Filter | 0 | 1 | Lower Bound Temperature Scale | 0 | 124 | Lower Bound Temperature Filter |
|
11 | Fan Timer | This configuration is used to activate the fan with an automatic shut-off timer. | 0 | 1 | 0 | 0 | 0 | From | To | Description |
|---|
0 | 60 | 0x00 Always On (DEFAULT) 0x0F 15 minutes 0x1E 30 minutes 0x3C 60 minutes |
|
1 | Temperature Reporting Threshold | The Temperature Reporting Threshold parameter specifies the threshold change in the ambient air temperature as detected by the thermostat to generate an usolicited report when association reporting is enabled. | 0 | 1 | 0 | 0 | 2 | From | To | Description |
|---|
0 | 4 | 0x00 Disable Reporting 0x01 0.5 degrees Fahrenheit 0x02 1.0 degrees Fahrenheit (DEFAULT) 0x03 1.5 degrees Fahrenheit 0x04 2.0 degrees Fahrenheit |
|
3 | Utility Lock | The Utility Lock parameter enables or disables the utility lock. If the utility lock is enabled, the thermostat setpoint cannot be modified by the user on the thermostat physical user interface. | 0 | 1 | 0 | 0 | 0 | From | To | Description |
|---|
0 | 3 | 0x00 Disabled lock (DEFAULT) 0x01 n/a 0x02 n/a 0x03 Enabled lock |
|
2 | HVAC Settings | The HVAC Settings parameter contains a read-only description of the HVAC settings of the thermostat. | 0 | 4 | 0 | 0 | 0 | From | To | Description |
|---|
0 | 255 | A Terminal, Heat Pump Stages | 0 | 255 | O/B Terminal, Cooling Stages | 0 | 255 | Heating Fuel, Heat/Aux Stages | 0 | 255 | Cooling Type, Heating Type |
|
7 | Thermostat Swing | The Thermostat Swing Temperature parameter specifies the swing temperature on the thermostat. | 0 | 1 | 0 | 0 | 2 | From | To | Description |
|---|
0 | 8 | 0x00 not supported 0x01 0.5 degrees Fahrenheit 0x02 1.0 degrees Fahrenheit (DEFAULT) 0x03 1.5 degrees Fahrenheit 0x04 2.0 degrees Fahrenheit 0x05 2.5 degrees Fahrenheit 0x06 3.0 degrees Fahrenheit 0x07 3.5 degrees Fahrenheit 0x08 4.0 degrees Fahrenheit |
|
6 | Auxiliary Heat | The Auxiliary Heat parameter enables or disables Thermostat Mode called Auxiliary Heating in the thermostat while the thermostat mode is Heat. | 0 | 1 | 0 | 0 | 0 | From | To | Description |
|---|
0 | 1 | 0x00 Disabled auxiliary heat (DEFAULT) 0x01 Enabled auxiliary heat |
|