Product Recognition | |
|---|
Certification Number | ZC10-19096738 |
|---|
Name | Dual Relay In-Wall Module |
|---|
Short Description | The dual relay in-wall module contains two sets of relays and switches, with each set dedicated for controlling lighting or an appliance in your home. |
|---|
Long Description | The dual relay in-wall module contains two sets of relays and switches, with each set dedicated for controlling lighting or an appliance in your home.
The module is a Z-Wave enabled device which is fully compatible with any Z-Wave enabled network.
Each relay can be turned on/off individually using Z-wave commands or using the switches connected to the module. At 230V voltage, this module can support up to 2*4.3A output, 2*1000W resistive load.
This unit is to be installed and sealed inside an electrical switch box. |
|---|
Brand | Everspring |
|---|
Product Identifier | AN196-0 |
|---|
Product Line | Z-Wave Plus 500 series |
|---|
OEM Version | HW: 1 FW: 1.01:00.01 |
|---|
Hardware Platform | SD3502 |
|---|
Z-Wave Version | 6.81.03 |
|---|
Library Type | SLAVE_ENHANCED_232 |
|---|
Device Type | On/Off Power Switch |
|---|
Role Type | ROLE_TYPE_SLAVE_ALWAYS_ON |
|---|
Manufacturer ID | 0x0060 |
|---|
Product Type ID | 0x0004 |
|---|
Product ID | 0x000E |
|---|
User Icon | 0x0702 |
|---|
Installer Icon | 0x0700 |
|---|
Frequency Plans | EU: 869.85MHz, 868.40MHz |
|---|
Categories | All Lighting Devices, On/Off Switches/Devices |
|---|
Countries / Regions | European Union |
|---|
Supported Command Classes | Identifier | Name | Key | Version |
|---|
COMMAND_CLASS_FIRMWARE_UPDATE_MD_V4 | Firmware Update Meta-Data V4 | 0x7A | 4 | COMMAND_CLASS_POWERLEVEL | Powerlevel | 0x73 | 1 | COMMAND_CLASS_MULTI_CHANNEL_ASSOCIATION_V3 | Multi-Channel Association V3 | 0x8E | 3 | COMMAND_CLASS_SWITCH_BINARY | Switch Binary | 0x25 | 1 | COMMAND_CLASS_BASIC | Basic | 0x20 | 1 | COMMAND_CLASS_CONFIGURATION | Configuration | 0x70 | 1 | COMMAND_CLASS_SECURITY | Security S0 | 0x98 | 1 | COMMAND_CLASS_TRANSPORT_SERVICE_V2 | Transport Service V2 | 0x55 | 2 | COMMAND_CLASS_DEVICE_RESET_LOCALLY | Device Reset Locally | 0x5A | 1 | COMMAND_CLASS_ZWAVEPLUS_INFO_V2 | Z-Wave Plus Info V2 | 0x5E | 2 | COMMAND_CLASS_ASSOCIATION_V2 | Association V2 | 0x85 | 2 | COMMAND_CLASS_ASSOCIATION_GRP_INFO | Association Group Info | 0x59 | 1 | COMMAND_CLASS_MULTI_CHANNEL_V4 | Multi-Channel V4 | 0x60 | 4 | COMMAND_CLASS_NOTIFICATION_V8 | Notification V8 | 0x71 | 8 | COMMAND_CLASS_SECURITY_2 | Security S2 | 0x9F | 1 | COMMAND_CLASS_VERSION_V3 | Version V3 | 0x86 | 3 | COMMAND_CLASS_SUPERVISION | Supervision | 0x6C | 1 | COMMAND_CLASS_MANUFACTURER_SPECIFIC_V2 | Manufacturer Specific V2 | 0x72 | 2 |
|
|---|
Controlled Command Classes | Identifier | Name | Key | Version |
|---|
COMMAND_CLASS_BASIC | Basic | 0x20 | 1 |
|
|---|
S2 Classes | S2_UNAUTHENTICATED, S2_AUTHENTICATED |
|---|
Documents | Category | Description | File |
|---|
Manual_English | Product Manual in English | | Manual_Primary_Lang | Product Manual | |
|
|---|
Features | Feature | Values |
|---|
Color | | Firmware Updatable | Value |
|---|
Updatable by Consumer by RF |
|
|
|---|
Association Groups | Group Number | Maximum Nodes Supported | End Point ID | Group Name | Description |
|---|
2 | 5 | 0 | On/Off Control | When switch 1 is pressed, a BASIC SET command containing a value will be sent to the node of Group 2 (When relay is off, Basic Set Value=0x00, when relay is on, Basic Set Value=0xFF).
| 3 | 5 | 0 | On/Off Control | When switch 2 is pressed, a BASIC SET command containing a value will be sent to the node of Group 3 (When relay is off, Basic Set Value=0x00, when relay is on, Basic Set Value=0xFF). | 1 | 5 | 0 | Lifeline | When the unit is powered up for first time, a Notification Report will be sent to the node of Group 1.
When performing Factory Reset, a Device Reset Locally Notification will be sent to the node of Group 1.
When relay is activated through the switch, the unit will send a Binary Switch Report to the node of Group 1.
|
|
|---|
Configuration Parameters | Parameter Number | Name | Description | Format | Size | Min Value | Max Value | Default Value | Parameter Values |
|---|
2 | Parameter 2 | Switch 2 Type | 1 | 1 | 0 | 1 | 0 | From | To | Description |
|---|
0 | 0 | Momentary | 1 | 1 | Toggle |
| 1 | Parameter 1 | Switch 1 Type | 1 | 1 | 0 | 1 | 0 | From | To | Description |
|---|
1 | 1 | Toggle | 0 | 0 | Momentary |
| 3 | Parameter 3 | Relay 1 Auto Off Time | 1 | 4 | 0 | 43200 | 0 | From | To | Description |
|---|
0 | 43200 | Max 12hrs |
| 4 | Parameter 4 | Relay 2 Auto Off Time | 1 | 4 | 0 | 43200 | 43200 | From | To | Description |
|---|
0 | 43200 | Max 12hrs |
| 5 | Parameter 5 | Set whether to remember the last status of Relay 1 | 1 | 1 | 0 | 1 | 1 | From | To | Description |
|---|
0 | 0 | do not remember | 1 | 1 | remember |
| 6 | Parameter 6 | Set whether to remember the last status of Relay 2 | 1 | 1 | 0 | 1 | 1 | From | To | Description |
|---|
0 | 0 | do not remember | 1 | 1 | remember |
|
|
|---|
Texts | ID | Description | Value |
|---|
2 | Classic Exclusion | 1. Put the Z-Wave Controller into exclusion mode.
2. Press the link key three times within 1.5 seconds to put the unit into exclusion mode. | 5 | Factory Reset Procedure | 1. Press the link key three times within 1.5 seconds to put the unit into exclusion mode.
2. Within 1 second of step 1, press link key again and hold until LED is off (about 5 seconds).
3. Node ID is excluded. The device reverts to factory default state and will be in auto-inclusion mode for 4 minutes.
(This procedure should only be used when the network primary controller is inoperable.) | 8 | Where to find S2 DSK on product | If you are connecting this unit to a Z-Wave Controller that utilizes the S2 security protocol, you may be asked to enter a 5 digit Device Specific Key (DSK) that is unique to each unit by your controller. This can be found in one of two places:
- on the QR code label on the back of the unit
- on the insert card inside the packaging | 1 | Classic Inclusion | 1. Put the Z-Wave Controller into inclusion mode.
2. Press the link key three times within 1.5 seconds to put the unit into inclusion mode. |
|
|---|
Supported Notification Types | Notification Type | Event / State |
|---|
Power Management | Power status: Power has been applied |
|
|---|
Supports NWI | Yes |
|---|
Supports Explorer Frames | Yes |
|---|
Supports SmartStart | Yes |
|---|
Radio Range Z-Wave (m) | 40 |
|---|