Product Recognition | |
|---|
Certification Number | ZC10-19096754 |
|---|
Name | Dimmer 400W |
|---|
Short Description | The in-wall dimmer is a Z-Wave device that is used to switch ON/OFF and adjust light intensity of the connected
light and can be controlled by other Z-Wave devices. |
|---|
Long Description | The in-wall dimmer is a Z-Wave device that is used to switch ON/OFF and adjust light intensity of the connected
light and can be controlled by other Z-Wave devices. The In-wall Dimmer can be included and operated in any
Z-Wave network with other Z-Wave certified devices from other manufacturers and/or other applications. All
non-battery operated nodes within the network will act as repeaters regardless of vendor to increase reliability
of the network.
The encryption mode that the dimmer supports is S2 Unauthenticated. When the dimmer is being included into
a Z-Wave network, you can use your primary controller/gateway to enable encryption mode or disable
encryption. (The primary controller/gateway shall support encryption mode configuration). The dimmer
supports OTA and can update firmware wirelessly. |
|---|
Brand | Namron |
|---|
Product Identifier | Dimmer 400W |
|---|
Product Line | Dimmer 400W |
|---|
OEM Version | HW: 1 FW: 1.00 |
|---|
Hardware Platform | ZM5101 |
|---|
Z-Wave Version | 6.71.01 |
|---|
Library Type | SLAVE_ENHANCED_232 |
|---|
Device Type | Light Dimmer Switch |
|---|
Role Type | ROLE_TYPE_SLAVE_ALWAYS_ON |
|---|
Manufacturer ID | 0x0438 |
|---|
Product Type ID | 0x0200 |
|---|
Product ID | 0xD005 |
|---|
User Icon | 0x0600 |
|---|
Installer Icon | 0x0600 |
|---|
Frequency Plans | EU: 869.85MHz, 868.40MHz |
|---|
Categories | All Lighting Devices, Dimming Lighting Devices |
|---|
Countries / Regions | European Union |
|---|
Supported Command Classes | Identifier | Name | Key | Version |
|---|
COMMAND_CLASS_FIRMWARE_UPDATE_MD_V4 | Firmware Update Meta-Data V4 | 0x7A | 4 | COMMAND_CLASS_SCENE_ACTUATOR_CONF | Scene Actuator Conf | 0x2C | 1 | COMMAND_CLASS_POWERLEVEL | Powerlevel | 0x73 | 1 | COMMAND_CLASS_SECURITY | Security S0 | 0x98 | 1 | COMMAND_CLASS_TRANSPORT_SERVICE_V2 | Transport Service V2 | 0x55 | 2 | COMMAND_CLASS_VERSION_V2 | Version V2 | 0x86 | 2 | COMMAND_CLASS_DEVICE_RESET_LOCALLY | Device Reset Locally | 0x5A | 1 | COMMAND_CLASS_ZWAVEPLUS_INFO_V2 | Z-Wave Plus Info V2 | 0x5E | 2 | COMMAND_CLASS_ASSOCIATION_V2 | Association V2 | 0x85 | 2 | COMMAND_CLASS_SWITCH_MULTILEVEL_V4 | Switch Multilevel V4 | 0x26 | 4 | COMMAND_CLASS_ASSOCIATION_GRP_INFO_V3 | Association Group Information V3 | 0x59 | 3 | COMMAND_CLASS_NOTIFICATION_V8 | Notification V8 | 0x71 | 8 | COMMAND_CLASS_BASIC_V2 | Basic V2 | 0x20 | 2 | COMMAND_CLASS_SECURITY_2 | Security S2 | 0x9F | 1 | COMMAND_CLASS_SUPERVISION | Supervision | 0x6C | 1 | COMMAND_CLASS_SCENE_ACTIVATION | Scene Activation | 0x2B | 1 | COMMAND_CLASS_CONFIGURATION_V2 | Configuration V2 | 0x70 | 2 | COMMAND_CLASS_MANUFACTURER_SPECIFIC_V2 | Manufacturer Specific V2 | 0x72 | 2 |
|
|---|
S2 Classes | S2_UNAUTHENTICATED |
|---|
Documents | Category | Description | File |
|---|
Manual_Primary_Lang | 4512710 INSTRUCTION MANUAL | |
|
|---|
Features | Feature | Values |
|---|
Firmware Updatable | Value |
|---|
Updatable by Consumer by RF |
|
|
|---|
Association Groups | Group Number | Maximum Nodes Supported | End Point ID | Group Name | Description |
|---|
1 | 5 | 0 | Lifeline | 1. When factory reset the dimmer, send "Device Reset Locally
Notification CC" to associated devices of this group to report
factory reset information.
2. When load state changes, send "Basic Report CC" to
associated devices of this group.
3. When a load malfunction is detected, send "Emergency
shutoff status" to Lifeline. |
|
|---|
Configuration Parameters | Parameter Number | Name | Description | Format | Size | Min Value | Max Value | Default Value | Parameter Values |
|---|
7 | Enable/disable external switch to be added to and removed from a network | Enable/disable external switch to be added to and removed from a network (when enables this function, triple press the external switch within 1.5 seconds to be added to or removed from a network) | 0 | 1 | 0 | 1 | 1 | From | To | Description |
|---|
0 | 0 | disable | 1 | 1 | enable |
| 2 | Saving load state before power failure | Saving load state before power failure | 0 | 1 | 0 | 2 | 0 | From | To | Description |
|---|
0 | 0 | shutoff load | 1 | 1 | turn on load | 2 | 2 | save load state before power failure |
| 3 | Enable/disable to send the basic report | Enable/disable to send the basic report to the Lifeline when the load state changed (When value set as 1, re-power on the dimmer, it will send Basic report automatically) | 0 | 1 | 0 | 1 | 1 | From | To | Description |
|---|
0 | 0 | Disable to send Basic report | 1 | 1 | Enable to send Basic report |
| 4 | Default fade time | Default fade time (unit is second, this value has the same function as Duration of Multilevel) | 0 | 1 | 0 | 255 | 1 | From | To | Description |
|---|
0 | 0 | Instantly | 1 | 127 | 1 second (0x01) to 127 seconds (0x7F) in 1 second resolution. | 128 | 254 | 1 minute (0x80) to 127 minutes (0xFE) in 1 minute resolution. | 255 | 255 | Factory default duration. (1 second) |
| 5 | Setting minimum brightness value | Setting minimum brightness value | 0 | 1 | 0 | 50 | 0 | From | To | Description |
|---|
0 | 50 | the bigger the value is, the higher the load’s minimum brightness is |
| 6 | Choose MOSFET driving type | Choose MOSFET driving type | 0 | 1 | 0 | 1 | 0 | From | To | Description |
|---|
0 | 0 | trailing edge | 1 | 1 | leading edge |
|
|
|---|
Texts | ID | Description | Value |
|---|
5 | Factory Reset Procedure | Press and hold down the action button for over 10 seconds, the dimmer will be reset to factory defaults.Please
use this procedure only when the network primary controller is missing or otherwise inoperable. | 2 | Classic Exclusion | There are two exclusion methods:
Method 1: Exclusion from the primary controller/gateway as follows:
1. Set the primary controller/gateway into exclusion mode (Please refer to your primary controllers manual on
how to set your controller into exclusion).
2. Triple press the action button, the dimmer will be set to exclusion mode, and waiting to be excluded, then the
dimmer will be excluded from the network.
Method 2: Factory reset the dimmer will force the it to be excluded from a network. (please refer to the part
“Factory Reset” of this manual) | 1 | Classic Inclusion | 1. Set primary controller/gateway into inclusion mode (Please refer to your primary controllers manual on how
to turn your controller into inclusion).
2. Power on the in-wall dimmer and set it into inclusion mode. There are two methods to set the in-wall dimmer
into inclusion mode:
1)Repower on the dimmer, it will be set into inclusion mode automatically, and waiting to be included.
2)Triple press the action button on the dimmer, it will set the dimmer into inclusion mode.
The connected light will stay solid on for 3 seconds to indicate successful inclusion. |
|
|---|
Supported Notification Types | Notification Type | Event / State |
|---|
System | Emergency shutoff status: Emergency shutoff |
|
|---|
Supports NWI | Yes |
|---|
Supports Explorer Frames | Yes |
|---|
Radio Range Z-Wave (m) | 40 |
|---|