4 | Automatic control - time of a dimming step | This parameter defines the time of single dimming step set in parameter 3 during the automatic control. Available settings:1-255(10ms-2.55s,in 10ms steps). Default value:1(10ms) | 1 | 2 | 1 | 255 | 1 | From | To | Description |
|---|
1 | 255 | Set the desired value from 1 to 255(10ms-2.55s,in 10ms steps) for the time of a dimming step. The amount of time the dimmer takes to adjust each step during the automatic control is the value set here. |
|
5 | Manual control - dimming step size | This parameter defines the percentage value of dimming step during the manual control. | 1 | 1 | 1 | 99 | 1 | From | To | Description |
|---|
1 | 99 | Set the desired value from 1 to 99% for dim step size;The dimmer is dimmed up or down based on the percentage of the value set here for each step during the manual control. |
|
6 | Manual control - time of a dimming step | This parameter defines the time of single dimming step set in parameter 5 during the manual control. Available settings:1-255(10ms-2.55s,in 10ms steps). Default value:5(50ms) | 1 | 2 | 1 | 255 | 5 | From | To | Description |
|---|
1 | 255 | Set the desired value from 1 to 255(10ms-2.55s,in 10ms steps) for the time of a dimming step. The amount of time the dimmer takes to adjust each step during the manual control is the value set here. |
|
7 | Memory function after power failure | If this parameter is set to 1,the Device will restore its brightness before power failure. | 1 | 1 | 0 | 1 | 1 | From | To | Description |
|---|
0 | 1 | Set the desired value from 0 to 1 to turn on/off the memory function.Setting this value to 0 turns off the dimmer's Memory fucntion.Setting this value to 1 truns on the dimmer's Memory function. |
|
8 | Scene ID set | Scene ID is set by this configuration. Note: The actual action of each SCENE ID are set by SCENE_ACTUATOR_CONF(0x26) command. | 1 | 2 | 1 | 255 | 1 | From | To | Description |
|---|
1 | 255 | Set the desired number from 1 to 255 as current scene ID.The dimmer will drive the load lamp based on the brightness stored in the scene ID set here,when the scene function is triggered.But the brightness value stored in each scene ID is set by the SCENE_ACTUATOR_CONF(0X26) command |
|
9 | Timer functionality (auto - off) | This parameter allows to automatically switch off the device after specified time from switching on the light source. It may be useful when the Zerodim Z-Wave is installed in the stairway. Available settings: 0 - Function disabled 1-32767 - time to turn off measured in seconds (1s-9.1h) | 1 | 2 | 0 | 32767 | 0 | From | To | Description |
|---|
0 | 32767 | Set the desired value from 0 to 32767(0--Function disable,1-32767--1s-32767s) fas the time at which the dimmer will automatically turn off.Setting this value to 0 will disable the dimmer's countdown function.Set this value to 1-32767 and the dimmer will turn off when the dimmer countdown reaches the set value. |
|
2 | Maximum brightness level | This parameter refers to the maximum brightness that the dimmer can achieve | 1 | 1 | 2 | 99 | 99 | From | To | Description |
|---|
2 | 99 | Set the desired value from 2 to 99% for the maximum dim level that the dimmer is restricted to; the dimmer will not go higher than the value set here. |
|
3 | Automatic control - dimming step size | This parameter defines the percentage value of dimming step during the automatic control. | 1 | 1 | 1 | 99 | 1 | From | To | Description |
|---|
1 | 99 | Set the desired value from 1 to 99% for dim step size;The dimmer is dimmed up or down based on the percentage of the value set here for each step during the automatic control. |
|