Product Recognition | |
|---|
Certification Number | ZC12-20110131 |
|---|
Name | Yale Assure SL Lock |
|---|
Short Description | Lock and unlock your door with ease using the touchscreen keypad. Integrate your Yale lock into your Z-Wave home automation or security system for ultimate convenience. |
|---|
Long Description | Never worry about carrying around or losing your keys again. Unlock and lock your home with ease from the backlit touchscreen keypad. Create unique pin codes for friends and family and remove codes whenever you need to. This Yale Real Living lock features Z-Wave technology and seamlessly integrates into 50+ home automation and security systems. When added to most Z-Wave automation systems, lock and unlock your door, create pin codes, view access history and receive notifications from anywhere. The lock is tamper resistant, easy to install and even easier to use! |
|---|
Brand | Yale |
|---|
Product Identifier | YRD256-ZW3 |
|---|
Product Line | Yale Assure |
|---|
OEM Version | HW: 2 FW: 2.13:43.19 |
|---|
Hardware Platform | ZGM130 |
|---|
Z-Wave Version | 7.12.2 |
|---|
Library Type | SLAVE_ENHANCED_232 |
|---|
Device Type | Lock |
|---|
Role Type | ROLE_TYPE_SLAVE_SLEEPING_LISTENING |
|---|
Manufacturer ID | 0x0129 |
|---|
Product Type ID | 0x8002 |
|---|
Product ID | 0x46D5 |
|---|
User Icon | 0x0300 |
|---|
Installer Icon | 0x0300 |
|---|
Frequency Plans | US: 916.00MHz, 908.40MHz |
|---|
Categories | All Controllers, Computer Controller Interfaces |
|---|
Countries / Regions | United States of America |
|---|
Supported Command Classes | Identifier | Name | Key | Version |
|---|
COMMAND_CLASS_CONFIGURATION_V4 | Configuration V4 | 0x70 | 4 | COMMAND_CLASS_POWERLEVEL | Powerlevel | 0x73 | 1 | COMMAND_CLASS_DOOR_LOCK_V4 | Door Lock V4 | | 0 | COMMAND_CLASS_USER_CODE_V2 | User Code V2 | | 0 | COMMAND_CLASS_MULTI_CHANNEL_ASSOCIATION_V3 | Multi-Channel Association V3 | 0x8E | 3 | COMMAND_CLASS_INDICATOR_V3 | Indicator V3 | 0x87 | 3 | COMMAND_CLASS_CLOCK | Clock | 0x81 | 1 | COMMAND_CLASS_BATTERY | Battery | 0x80 | 1 | COMMAND_CLASS_APPLICATION_STATUS | Application Status | 0x22 | 1 | COMMAND_CLASS_TIME_PARAMETERS | Time Parameters | 0x8B | 1 | COMMAND_CLASS_SECURITY | Security S0 | 0x98 | 1 | COMMAND_CLASS_TIME_V2 | Time V2 | 0x8A | 2 | COMMAND_CLASS_TRANSPORT_SERVICE_V2 | Transport Service V2 | 0x55 | 2 | COMMAND_CLASS_DEVICE_RESET_LOCALLY | Device Reset Locally | 0x5A | 1 | COMMAND_CLASS_ZWAVEPLUS_INFO_V2 | Z-Wave Plus Info V2 | 0x5E | 2 | COMMAND_CLASS_ASSOCIATION_V2 | Association V2 | 0x85 | 2 | COMMAND_CLASS_FIRMWARE_UPDATE_MD_V5 | Firmware Update Meta-Data V5 | 0x7A | 5 | COMMAND_CLASS_ASSOCIATION_GRP_INFO_V3 | Association Group Information V3 | 0x59 | 3 | COMMAND_CLASS_NOTIFICATION_V8 | Notification V8 | 0x71 | 8 | COMMAND_CLASS_BASIC_V2 | Basic V2 | 0x20 | 2 | COMMAND_CLASS_DOOR_LOCK_LOGGING | Door Lock Logging | 0x4C | 1 | COMMAND_CLASS_SECURITY_2 | Security S2 | 0x9F | 1 | COMMAND_CLASS_VERSION_V3 | Version V3 | 0x86 | 3 | COMMAND_CLASS_SUPERVISION | Supervision | 0x6C | 1 | COMMAND_CLASS_MANUFACTURER_SPECIFIC_V2 | Manufacturer Specific V2 | 0x72 | 2 | COMMAND_CLASS_SCHEDULE_ENTRY_LOCK_V3 | Schedule Entry Lock V3 | 0x4E | 3 |
|
|---|
S2 Classes | S2_ACCESS_CONTROL |
|---|
Documents | Category | Description | File |
|---|
Manual_Primary_Lang | Product Manual | |
|
|---|
Features | Feature | Values |
|---|
Color | | Communications Connections | | Communications Protocol | Value |
|---|
Manufacturer Proprietary Protocol |
| Controller Supports Multiple Z-Wave Interfaces | | Firmware Updatable | |
|
|---|
Association Groups | Group Number | Maximum Nodes Supported | End Point ID | Group Name | Description |
|---|
1 | 3 | 0 | Lifeline | the description is lifeline. |
|
|---|
Configuration Parameters | Parameter Number | Name | Description | Format | Size | Min Value | Max Value | Default Value | Parameter Values |
|---|
2 | Auto Relock | Set Auto Relock feature to enable or disable. | 2 | 1 | 0 | 255 | 0 | From | To | Description |
|---|
0 | 255 | Auto Relock |
| 7 | Shut Down Time | Adjust the time your lock is shutdown after reaching its wrong code entry limit. | 2 | 1 | 0 | 132 | 60 | From | To | Description |
|---|
0 | 132 | Shut Down Time |
| 8 | Operating Mode | Set the Operating Mode to normal mode(0), vacation mode(1) or privacy mode(2). | 2 | 1 | 0 | 2 | 0 | From | To | Description |
|---|
0 | 2 | Operating Mode |
| 1 | Volume | Set Volume Level to high (1), low (2), or silent (3). | 2 | 1 | 1 | 3 | 2 | From | To | Description |
|---|
1 | 3 | Volume |
| 5 | Language | Set the language to English (1), Spanish (2), or French (3). | 2 | 1 | 1 | 3 | 1 | From | To | Description |
|---|
1 | 3 | Language |
| 4 | Wrong Code Entry Limit | Adjust the limit for wrong code entries allowed by your lock. | 2 | 1 | 0 | 5 | 5 | From | To | Description |
|---|
0 | 5 | Wrong Code Entry Limit |
| 11 | One Touch Locking | Set One Touch Locking feature to enable or disable. | 2 | 1 | 0 | 255 | 255 | From | To | Description |
|---|
0 | 255 | One Touch Locking |
|
|
|---|
Texts | ID | Description | Value |
|---|
8 | Where to find S2 DSK on product | Sticker on module and insert | 2 | Classic Exclusion | Open Z-Wave system's smart home or alarm app and follow instructions for removing a device
2. On your lock keypad, enter your master entry code followed by the icon
3. Press the 7 key followed by the gear icon
4. Press the 3 key followed by the gear icon | 4 | Wake-Up Procedure | Press Yale logo to wake up lock | 1 | Classic Inclusion | Install Yale Smart Module into slot above battery compartment
IMPORTANT: Batteries must be removed before inserting Yale Smart Module:
• Remove battery cover
• Remove batteries
• Insert Yale Smart Module
• Reinstall batteries
• Reinstall battery cover
2. Open Z-Wave system's smart home or alarm app on your smartphone or tablet
3. If you have Smart Start* enabled with your Z-Wave System follow in-app prompts to add a new device
If you don't have smart start or are not sure, follow steps 4 - 6
4. On your lock keypad, enter your master entry code followed by the gear icon
5. Press the 7 key followed by the gear icon
6. Press the 1 key followed by the gear icon | 5 | Factory Reset Procedure | Remove the battery cover and batteries.
Remove the interior escutcheon to access the reset button.
The reset button is located above the PCB cable connector.
While pressing the reset button for a minimum of 3 seconds, reinstall batteries. Release reset button.
Replace battery cover.
Please use this procedure only when the network primary controller is missing or otherwise inoperable | 6 | Other Special Features | Paragraph 8. Compability/ Principles for regulation. Water based heating - Electrical heating.
Paragraph 9. Information shown in display. The main screen - Secondary screen - Connecting to an external relay.
Paragraph 10. Hysteresis.
Paragraph 11. Child lock.
Paragraph 12. Standby and main screen. |
|
|---|
Supported Notification Types | Notification Type | Event / State |
|---|
Access Control | (Refer to parameters): State idle | Access Control | Manual lock operation | Access Control | Manual unlock operation | Access Control | RF lock operation | Access Control | RF unlock operation | Access Control | Keypad lock operation | Access Control | Keypad unlock operation | Access Control | Manual not fully locked operation | Access Control | RF not fully locked operation | Access Control | Auto lock locked operation | Access Control | Auto lock not fully locked operation | Access Control | Lock state: Lock jammed | Access Control | All user codes deleted | Access Control | Single user code deleted | Access Control | New user code added | Access Control | New user code not added due to duplicate code | Access Control | Keypad state: Keypad temporary disabled | Access Control | Keypad state: Keypad busy | Access Control | New program code entered : unique code for lock configuration | Access Control | Manually enter user access code exceeds code limit | Access Control | Unlock by RF with invalid user code | Access Control | Locked by RF with invalid user code | Access Control | Door state: Window/door is open | Access Control | Door state: Window/door is closed | Power Management | Power status: Power has been applied | Power Management | Battery maintenance status: Replace battery soon | Power Management | Battery maintenance status: Replace battery now |
|
|---|
Supports NWI | Yes |
|---|
Supports Explorer Frames | Yes |
|---|
Is Flirs | Yes |
|---|
Supports SmartStart | Yes |
|---|
Radio Range Z-Wave (m) | 40 |
|---|