2 | Acoustic and visual signals On / Off in case of flooding | The parameter allows for the deactivation of visual and acoustic alarms. The parameter allows for increasing battery life. Setting changes will not affect the sensor’s communication with the main controller - the device will still
send commands to association groups, alarms, and reports. | 1 | 1 | 0 | 3 | 3 | From | To | Description |
|---|
0 | 3 | Acoustic and visual signals On / Off in case of flooding |
|
1 | Alarm cancellation delay | Determines time period (in seconds) by which a Flood-Control will retain the flood state after the flooding itself has
ceased. The sensor will keep on reporting flooding to the main controller. This parameter setting does not affect
acoustic and visual alarms, which turn off immediately after flooding ceases. | 1 | 2 | 0 | 3600 | 0 | From | To | Description |
|---|
0 | 3600 | Alarm cancellation delay |
|
3 | Requested dimming level / roller blind opening level when sending turn on / open command to 2nd association group devices | Determines the requested “on” level to be sent to devices from 2nd association group upon flood event. | 1 | 2 | 1 | 255 | 255 | From | To | Description |
|---|
1 | 255 | Requested dimming level / roller blind opening level when sending turn on / open command to 2nd association group devices |
|
4 | Deactivate turning off devices in 2nd association group & alarm cancellation in 3rd group | This setting decides whether device turn off commands and alarm cancellation notifications will be sent to devices
in 2nd and 3rd association groups (respectively)
Setting the parameter’s value to 0 disables sending these two commands to associated devices. This means that
these devices WILL NOT be informed when the flooding has ceased. It is still possible to cancel alarms in 3rd association group by choosing second (green) menu position (see section 8.2 - Visual indications) | 1 | 1 | 0 | 1 | 1 | From | To | Description |
|---|
0 | 1 | Deactivate turning off devices in 2nd association group & alarm cancellation in 3rd group |
|
5 | Temperature measurement interval | Time interval (in seconds) between consecutive measurements of battery level and temperature (done by built-in
temperature sensor).
If the temperature differs from previously reported by a value determined in parameter 12, it will be reported to
the Z-Wave controller.
In battery mode more significant battery level changes will be reported. Short time intervals mean more frequent
communication, which results in shortened battery life.
After consecutive FAILED and SUCCESSFUL communication attempts, the Sensor will go to standby mode. | 1 | 4 | 1 | 65535 | 300 | From | To | Description |
|---|
1 | 65535 | Temperature measurement interval |
|
6 | Temperature measurement hysteresis | Determines a minimum temperature change value (insensitivity level), resulting in a temperature report being sent
to the main controller, according to the parameter 10 settings. | 1 | 2 | 1 | 1000 | 50 | From | To | Description |
|---|
1 | 1000 | Temperature measurement hysteresis |
|
7 | Low temperature alarm threshold | The parameter stores a temperature value, below which visual indicator blinks with a colour determined by a
parameter 61 settings. By default the visual indicator blinks blue. | 1 | 2 | -10000 | 10000 | 1500 | From | To | Description |
|---|
-10000 | 10000 | Low temperature alarm threshold |
|
8 | High temperature alarm threshold | The parameter stores a temperature value, above which visual indicator blinks with a colour determined by the
parameter 62 settings. By default the visual indicator blinks red. | 1 | 2 | -10000 | 10000 | 3500 | From | To | Description |
|---|
-10000 | 10000 | High temperature alarm threshold |
|
9 | Low temperature alarm indicator colour | Parameter stores RGB colour value (see Table A3 for details). | 1 | 4 | 0 | 16777215 | 255 | From | To | Description |
|---|
0 | 16777215 | Low temperature alarm indicator colour |
|
10 | High temperature alarm indicator colour | Parameter stores RGB colour value (see Table A3 for details). | 1 | 4 | 0 | 16777215 | 16711680 | From | To | Description |
|---|
0 | 16777215 | High temperature alarm indicator colour |
|
11 | Temperature indication using LED visual indicator | Parameter determines visual indicator’s operation. Setting to 0 turns the temperature LED indication off, saving
battery life. | 1 | 1 | 0 | 2 | 2 | From | To | Description |
|---|
0 | 2 | Temperature indication using LED visual indicator |
|
17 | Associations in Z-Wave network security mode | This parameter defines how commands are sent in specified association groups: as secure or non-secure. Parameter is active only in Z-Wave network security mode. It does not apply to 1st “Lifeline “group. | 1 | 1 | 0 | 7 | 7 | From | To | Description |
|---|
0 | 7 | Associations in Z-Wave network security mode |
|