Product Recognition | |
|---|
Certification Number | ZC14-23090328 |
|---|
Name | DC Signal Sensor |
|---|
Short Description | Use the DC Signal Sensor as a smart bridge between analog smoke and CO detectors and your Z-Wave™ hub. |
|---|
Long Description | PRODUCT HIGHLIGHTS:
- Z-Wave™ alerts from low-voltage trigger signals
- Connect to smoke or CO detectors to monitor activity
- 120 V relay to control a security siren or lights
- Installs in the box with the last smoke detector in series
- 800 series Z-Wave™ chip for better range and faster control
- Z-Wave™ Long Range for ultra reliable no-mesh communication
- Advanced settings to customize the device’s behavior
- Built-in Z-Wave™ signal repeater for boosted communication
- SmartStart and S2 Authenticate Security for a safer network |
|---|
Brand | Zooz |
|---|
Product Identifier | ZEN55 LR |
|---|
Product Line | Smart Relays |
|---|
OEM Version | HW: 01 FW: 01.11 |
|---|
Hardware Platform | EFR32ZG23A |
|---|
Z-Wave Version | 7.18.3 |
|---|
Library Type | END_NODE_ENHANCED_232 |
|---|
Device Type | Notification Sensor DT |
|---|
Role Type | ROLE_TYPE_SLAVE_ALWAYS_ON |
|---|
Manufacturer ID | 0x027A |
|---|
Product Type ID | 0x0004 |
|---|
Product ID | 0x0110 |
|---|
User Icon | 0x0C00 |
|---|
Installer Icon | 0x0C00 |
|---|
Frequency Plans | US: 916.00MHz, 908.40MHz, US_LR: 912.00MHz, 920.00MHz |
|---|
Categories | Security Add-Ons |
|---|
Countries / Regions | Argentina, Bahamas, Barbados, Bermuda, Bolivia, British Virgin Islands, Canada, Cayman Islands, Colombia, Ecuador, Guatemala, Haiti, Honduras, Jamaica, Mexico, Panama, Saint Kitts and Nevis, Suriname, Trinidad and Tobago, Turks and Caicos Islands, United States of America |
|---|
Supported Command Classes | Identifier | Name | Key | Version |
|---|
COMMAND_CLASS_BASIC_V2 | Basic V2 | 0x20 | 2 | COMMAND_CLASS_CONFIGURATION_V4 | Configuration V4 | 0x70 | 4 | COMMAND_CLASS_APPLICATION_STATUS | Application Status | 0x22 | 1 | COMMAND_CLASS_ASSOCIATION_V2 | Association V2 | 0x85 | 2 | COMMAND_CLASS_ASSOCIATION_GRP_INFO_V3 | Association Group Information (AGI) V3 | 0x59 | 3 | COMMAND_CLASS_DEVICE_RESET_LOCALLY | Device Reset Locally | 0x5A | 1 | COMMAND_CLASS_FIRMWARE_UPDATE_MD_V5 | Firmware Update Meta Data V5 | 0x7A | 5 | COMMAND_CLASS_INDICATOR_V3 | Indicator V3 | 0x87 | 3 | COMMAND_CLASS_MANUFACTURER_SPECIFIC_V2 | Manufacturer Specific V2 | 0x72 | 2 | COMMAND_CLASS_MULTI_CHANNEL_ASSOCIATION_V3 | Multi Channel Association V3 | 0x8E | 3 | COMMAND_CLASS_VERSION_V3 | Version V3 | 0x86 | 3 | COMMAND_CLASS_ZWAVEPLUS_INFO_V2 | Z-Wave Plus Info V2 | 0x5E | 2 | COMMAND_CLASS_SECURITY_2 | Security 2 | 0x9F | 1 | COMMAND_CLASS_SUPERVISION | Supervision | 0x6C | 1 | COMMAND_CLASS_TRANSPORT_SERVICE_V2 | Transport Service V2 | 0x55 | 2 | COMMAND_CLASS_POWERLEVEL | Powerlevel | 0x73 | 1 | COMMAND_CLASS_NOTIFICATION_V8 | Notification V8 | 0x71 | 8 | COMMAND_CLASS_SWITCH_BINARY_V2 | Binary Switch V2 | 0x25 | 2 | COMMAND_CLASS_MULTI_CHANNEL_V4 | Multi Channel V4 | 0x60 | 4 |
|
|---|
S2 Classes | S2_AUTHENTICATED, S2_UNAUTHENTICATED |
|---|
Documents | Category | File |
|---|
Manual_English | |
|
|---|
Features | Feature | Values |
|---|
Firmware Updatable | Value |
|---|
Updatable by Consumer by RF |
| Neutral Wire Required | |
|
|---|
Association Groups | Group Number | Maximum Nodes Supported | End Point ID | Group Name | Profile |
|---|
1 | 5 | 0 | Lifeline | 0x0001 | 2 | 5 | 0 | Smoke Alarm | 0x2001 | 3 | 5 | 0 | CO Alarm | 0x2001 | 4 | 5 | 0 | On/Off Control | 0x2001 | 1 | 0 | 1 | Lifeline | 0x0001 | 2 | 5 | 1 | Smoke Alarm | 0x2001 | 1 | 0 | 2 | Lifeline | 0x0001 | 2 | 5 | 2 | CO Alarm | 0x2001 | 1 | 0 | 3 | Lifeline | 0x0001 | 2 | 5 | 3 | On/Off Control | 0x2001 |
|
|---|
Configuration Parameters | Parameter Number | Name | Description | Format | Size | Min Value | Max Value | Default Value |
|---|
1 | Led indicator status | Led indicator status | 2 | 1 | 0 | 0 | 0x01 | 2 | Alarm trigger Relay Control | Alarm trigger Relay Control | 2 | 1 | 0 | 0 | 0x01 | 3 | Auto turn-off timer | Auto turn-off timer | 1 | 4 | 0 | 0 | 0x00000000 | 4 | Auto turn-on timer | Auto turn-on timer | 1 | 4 | 0 | 0 | 0x00000000 | 5 | Restores state after power failure | Restores state after power failure | 2 | 1 | 0 | 0 | 0x02 | 6 | Smoke alarm group control | Smoke alarm group control | 2 | 1 | 0 | 0 | 0x00 | 7 | CO alarm group control | CO alarm group control | 2 | 1 | 0 | 0 | 0x00 | 8 | Enable or Disable Z-Wave Control | Enable or Disable Z-Wave Control | 2 | 1 | 0 | 0 | 0x00 |
|
|---|
Texts | ID | Description | Value |
|---|
8 | Where to find S2 DSK on product | Page 2 under Z-Wave Control: The SmartStart security PIN is located on the back of the device, next to the ETL logo. | 1 | Classic Inclusion | 1. Initiate inclusion (pairing) in the app (or web interface).
2. TAP THE Z-WAVE BUTTON 3 TIMES QUICKLY if using traditional Z-Wave inclusion.
3. The LED indicator will blink blue to signal communication and turn green for 2 seconds if inclusion is successful or turn red for 2 seconds if the pairing attempt fails. | 2 | Classic Exclusion | 1. Bring your Z-Wave gateway (hub) close to the switch if possible
2. Put the Z-Wave hub into exclusion mode (not sure how to do that? ask@getzooz.com)
3. Tap the Z-Wave button 3 times quickly (the LED indicator will start blinking blue)
4. Your hub will confirm exclusion, the LED indicator on the switch will turn green for 2 seconds, and the device will disappear from your controller's device list | 5 | Factory Reset Procedure | If your primary controller is missing or inoperable, you may need to reset the device to factory settings. To reset the ZEN55, click the Z-Wave™ button once and immediately after, press and hold it down for 15 seconds. The LED
indicator will flash during the process and turn red for 3 seconds to confirm successful reset.
NOTE: All previously recorded activity and custom settings will be erased from the device’s memory. |
|
|---|
Supported Notification Types | Notification Type | Event / State |
|---|
Smoke Alarm | (Refer to parameters): State idle | Smoke Alarm | Sensor status: Smoke detected | CO Alarm | (Refer to parameters): State idle | CO Alarm | Sensor status: Carbon monoxide detected |
|
|---|
Supports NWI | Yes |
|---|
Supports Explorer Frames | Yes |
|---|
Supports SmartStart | Yes |
|---|
Radio Range Z-Wave (m) | 40 |
|---|
Radio Range Z-Wave LR (m) | 400 |
|---|