Product Recognition | |
|---|
Certification Number | ZC10-17095782 |
|---|
Name | Heat Alarm |
|---|
Short Description | Heat alarm is an alarm device |
|---|
Long Description | Heat alarm is an alarm device that can give off warning under the condition that the environmental temperature between 54℃-70℃—the abnormal temperature may caused by an actual fire, in order to alert the dwelling of the dangerous situation and notice them to evacuate right away. At the same time in this alarm state if the alarms have been matched Smart home or other Z-Wave system, they will send a warning message to the main controller in this network group. The heat alarm can be
included and operated in any Z-Wave network with other Z-Wave certified devices from other manufacturers under the same radio frequency. It is the point that only under same radio frequency the heat alarm can be included and operated. All non-battery operated alarms within the network will act as repeaters, as to increase reliability of the network. In the Z-Wave network communication, the heat alarm can communicate with other devices associated. Through the Z-Wave network controller, you can get the status of the alarm, such as battery level. |
|---|
Brand | siterwell |
|---|
Product Identifier | GS412B |
|---|
OEM Version | HW: 255 FW: 1.01:01.01 |
|---|
Hardware Platform | ZM5202 |
|---|
Z-Wave Version | 6.71.01 |
|---|
Library Type | SLAVE_ROUTING |
|---|
Device Type | Notification Sensor |
|---|
Role Type | ROLE_TYPE_SLAVE_SLEEPING_REPORTING |
|---|
Manufacturer ID | 0x0266 |
|---|
Product Type ID | 0x0007 |
|---|
Product ID | 0x0001 |
|---|
User Icon | 0x0C04 |
|---|
Installer Icon | 0x0C04 |
|---|
Frequency Plans | EU: 869.85MHz, 868.40MHz |
|---|
Categories | Sensors |
|---|
Countries / Regions | European Union |
|---|
Supported Command Classes | Identifier | Name | Key | Version |
|---|
COMMAND_CLASS_POWERLEVEL | Powerlevel | 0x73 | 1 | COMMAND_CLASS_MULTI_CHANNEL_ASSOCIATION_V3 | Multi-Channel Association V3 | 0x8E | 3 | COMMAND_CLASS_BATTERY | Battery | 0x80 | 1 | COMMAND_CLASS_TRANSPORT_SERVICE_V2 | Transport Service V2 | 0x55 | 2 | COMMAND_CLASS_VERSION_V2 | Version V2 | 0x86 | 2 | COMMAND_CLASS_WAKE_UP_V2 | Wake Up V2 | 0x84 | 2 | COMMAND_CLASS_DEVICE_RESET_LOCALLY | Device Reset Locally | 0x5A | 1 | COMMAND_CLASS_ZWAVEPLUS_INFO_V2 | Z-Wave Plus Info V2 | 0x5E | 2 | COMMAND_CLASS_ASSOCIATION_V2 | Association V2 | 0x85 | 2 | COMMAND_CLASS_ASSOCIATION_GRP_INFO_V3 | Association Group Information V3 | 0x59 | 3 | COMMAND_CLASS_NOTIFICATION_V8 | Notification V8 | 0x71 | 8 | COMMAND_CLASS_SECURITY_2 | Security S2 | 0x9F | 1 | COMMAND_CLASS_SUPERVISION | Supervision | 0x6C | 1 | COMMAND_CLASS_MANUFACTURER_SPECIFIC_V2 | Manufacturer Specific V2 | 0x72 | 2 |
|
|---|
Controlled Command Classes | Identifier | Name | Key | Version |
|---|
COMMAND_CLASS_BASIC_V2 | Basic V2 | 0x20 | 2 |
|
|---|
S2 Classes | S2_UNAUTHENTICATED |
|---|
Documents | Category | Description | File |
|---|
Manual_Primary_Lang | Product or Owner's Manual | |
|
|---|
Features | Feature | Values |
|---|
Battery Quantity | | Supported Notification Types | | Battery Type | |
|
|---|
Association Groups | Group Number | Maximum Nodes Supported | End Point ID | Description |
|---|
1 | 5 | 0 | Z-Wave Plus Lifeline | 3 | 5 | 0 | Linkage group 3 reports the detection's status to the associated device. heat alarm. | 2 | 5 | 0 | Linkage group 2 is assigned to the devices status - sending BASIC SET control frame to the associated
devices having detected the heat alarm.
This heat alarm will send a “BASIC SET(0xFF)” message to associated group, when pressing test button to check the function; and this heat alarm will also send a “BASIC SET(0x00)” message to associated group, when quiting the test button. This heat alarm will send a “BASIC SET(0xFF)” message to associated group, when the heat alarm is overheat alarm; and this heat alarm will also send a “BASIC SET(0x00)” message to associated group, when the overheat alarm is cleared.
|
|
|---|
Texts | ID | Description | Value |
|---|
5 | Factory Reset | This operation will delete all information on Z-Wave network, and restore the factory default setting.
1. Remove the battery.
2. Press the button and don't release. And then connect the battery, the red light will on 3 seconds,3 seconds later, then release the button when the red light is off.
3. The red light is on for 3 seconds when the button is released. During these 3 seconds, press the button. Only after hearing a beep, restore factory settings successfully.
Note:
a. Please use this procedure only when the network main controller is missing or inoperable. | 2 | Exclusion | 1. Make sure the battery is installed well before operating the product.
2. Set the main controller into the remove (exclusion ) mode.
3. Quickly press the test button three times within two seconds, the red LED will light up.
4. Wait for the main controller to remove(exclusion) the alarm. If the remove(exclusion) is successful, the red LED flashes for about two seconds, and then exit the remove mode automatically.
Note:
a. If the alarm is removed(excluded), the alarm will be restored to factory default settings.
b.When the alarm is in “Add” or “Remove” mode, you can press the test button to exit and return to operating mode. | 1 | Inclusion | The heat alarm can be included to the Z-Wave network by following operations:
1. Make sure the battery is installed well before operating the product.
2. Make sure the alarm is on its final installation position, and then set a main controller into the add (inclusion ) mode.
3. Quickly press the test button three times within two seconds, the red LED will light up.
4. If the red LED flashes for about two seconds, it indicates that the alarm have been added (included) successfully, otherwise repeat the operation accordingly. |
|
|---|
Supported Notification Types | Notification Type | Event / State |
|---|
Heat Alarm | (Refer to parameters): State idle |
|
|---|
Supports NWI | Yes |
|---|
Supports Explorer Frames | Yes |
|---|