Product Recognition | |
|---|
Certification Number | ZC10-18106278 |
|---|
Name | Mini plug with metering |
|---|
Short Description | The Metering Plug is designed to turn on/off the appliances in your house. Its metering function can measure electricity usage in KW/hr and supports individual measurements of wattage, voltage, current and Power Factor. |
|---|
Long Description | The AN184 is a miniature size on/off and metering plug to control lighting and appliances. It is possible to turn on/off home devices and check the status directly from a smartphone.
Compact in design, yet certified for safety by makes it suitable for plugging into any power outlet. The metering plug can support wattage, voltage, ampere, and measurement. The unit can also detect overload upon which the unit will switch off relay and keep LED flashing until power is off and re-applied. |
|---|
Brand | Everspring |
|---|
Product Identifier | AN184-1 |
|---|
OEM Version | HW: 1 FW: 1.00:00.04 |
|---|
Hardware Platform | SD3502 |
|---|
Z-Wave Version | 6.71.03 |
|---|
Library Type | SLAVE_ENHANCED_232 |
|---|
Device Type | On/Off Power Switch |
|---|
Role Type | ROLE_TYPE_SLAVE_ALWAYS_ON |
|---|
Manufacturer ID | 0x0060 |
|---|
Product Type ID | 0x0004 |
|---|
Product ID | 0x000B |
|---|
User Icon | 0x0701 |
|---|
Installer Icon | 0x0701 |
|---|
Frequency Plans | US: 916.00MHz, 908.40MHz |
|---|
Categories | Energy Meters |
|---|
Countries / Regions | United States of America |
|---|
Supported Command Classes | Identifier | Name | Key | Version |
|---|
COMMAND_CLASS_FIRMWARE_UPDATE_MD_V4 | Firmware Update Meta-Data V4 | 0x7A | 4 | COMMAND_CLASS_POWERLEVEL | Powerlevel | 0x73 | 1 | COMMAND_CLASS_APPLICATION_STATUS | Application Status | 0x22 | 1 | COMMAND_CLASS_SWITCH_BINARY | Switch Binary | 0x25 | 1 | COMMAND_CLASS_BASIC | Basic | 0x20 | 1 | COMMAND_CLASS_CONFIGURATION | Configuration | 0x70 | 1 | COMMAND_CLASS_SECURITY | Security S0 | 0x98 | 1 | COMMAND_CLASS_TRANSPORT_SERVICE_V2 | Transport Service V2 | 0x55 | 2 | COMMAND_CLASS_VERSION_V2 | Version V2 | 0x86 | 2 | COMMAND_CLASS_DEVICE_RESET_LOCALLY | Device Reset Locally | 0x5A | 1 | COMMAND_CLASS_ZWAVEPLUS_INFO_V2 | Z-Wave Plus Info V2 | 0x5E | 2 | COMMAND_CLASS_ASSOCIATION_V2 | Association V2 | 0x85 | 2 | COMMAND_CLASS_METER_V3 | Meter V3 | 0x32 | 3 | COMMAND_CLASS_ASSOCIATION_GRP_INFO | Association Group Info | 0x59 | 1 | COMMAND_CLASS_SECURITY_2 | Security S2 | 0x9F | 1 | COMMAND_CLASS_SUPERVISION | Supervision | 0x6C | 1 | COMMAND_CLASS_MANUFACTURER_SPECIFIC_V2 | Manufacturer Specific V2 | 0x72 | 2 | COMMAND_CLASS_NOTIFICATION_V4 | Notification V4 | 0x71 | 4 |
|
|---|
Controlled Command Classes | Identifier | Name | Key | Version |
|---|
COMMAND_CLASS_BASIC | Basic | 0x20 | 1 |
|
|---|
S2 Classes | S2_UNAUTHENTICATED, S2_AUTHENTICATED |
|---|
Documents | Category | Description | File |
|---|
Manual_Primary_Lang | Product or Owner's Manual | |
|
|---|
Features | Feature | Values |
|---|
Color | | Firmware Updatable | Value |
|---|
Updatable by Consumer by RF |
| Supported Meter Type | | Supported Notification Types | |
|
|---|
Association Groups | Group Number | Maximum Nodes Supported | End Point ID | Description |
|---|
1 | 1 | 0 | Z-Wave Plus Lifeline | 2 | 4 | 0 | On/Off Control |
|
|---|
Configuration Parameters | Parameter Number | Name | Description | Format | Size | Min Value | Max Value | Default Value | Parameter Values |
|---|
2 | Set the delaying time to report to Group 1 | Value can be set 3~25 seconds | 0 | 1 | 0 | 0 | 3 | From | To | Description |
|---|
3 | 25 | Delaying time to report to Group 1 |
| 3 | Set whether to remember the last status | Value can be set 1 or 0 | 0 | 1 | 0 | 0 | 1 | From | To | Description |
|---|
0 | 1 | Remember or not remember the last status |
| 4 | Set the interval for wattage auto report | Value can be set 1~32767 minutes | 0 | 2 | 0 | 0 | 1 | From | To | Description |
|---|
1 | 32767 | The interval for wattage auto report |
| 5 | Set the interval for kW*h auto report | Value can be set 1~32767 minutes | 0 | 2 | 0 | 0 | 60 | From | To | Description |
|---|
1 | 32767 | The interval for kW*h auto report |
| 6 | Auto report when load surpasses the set value of wattage | Value can be set 0~3500W | 0 | 2 | 0 | 0 | 0 | From | To | Description |
|---|
0 | 3500 | 0: does not report automatically |
| 7 | Auto report when the change of wattage surpasses the set percentage | Value can be set 0~100% | 0 | 1 | 0 | 0 | 0 | From | To | Description |
|---|
0 | 100 | 0: does not report automatically |
| 1 | Set Basic Set Command value | Value can be set 0~99, 255 | 0 | 2 | 0 | 0 | 255 | From | To | Description |
|---|
0 | 99 | Basic Set Command value | 255 | 255 | 0xFF |
|
|
|---|
Texts | ID | Description | Value |
|---|
1 | Inclusion | 1. Put the Z-Wave Controller into inclusion mode.
2. Press the link key three times within 1.5 seconds to put the unit into inclusion mode. | 2 | Exclusion | 1. Put the Z-Wave Controller into exclusion mode.
2. Press the link key three times within 1.5 seconds to put the unit into exclusion mode. | 5 | Factory Reset | 1. Press the link key three times within 1.5 seconds to put the unit into exclusion mode.
2. Within 1 second of step 1, press link key again and hold it until LED is off (about 5 seconds).
3. Node ID is excluded. The device reverts to factory default state and will be in auto-inclusion mode for 25 secs.
(Use this procedure only in the event that the network primary controller is missing, or otherwise inoperable.) |
|
|---|
Supported / Controlled Meter Types | Meter Type | Rate Type | Description |
|---|
Electric meter | Import | Electric Meter Consumption |
|
|---|
Supported Notification Types | Notification Type | Event / State |
|---|
Power Management | (Refer to parameters): State idle |
|
|---|
Supports NWI | Yes |
|---|
Supports Explorer Frames | Yes |
|---|
Radio Range Z-Wave (m) | 40 |
|---|