| 200 | Partner ID | This parameter is used to configure the partner ID. 0== Aeon Labs Standard Product, 1~255== others. | 0 | 1 | 0 | 0 | 0 | | From | To | Description |
|---|
| 0 | 255 | There are 255 different partners can be configured. |
|
| 252 | Enable/Disable Lock Configuration | This parameter is used to Enable/Disable Lock all configuration parameters. (0 =disable, 1 = enable) | 0 | 1 | 0 | 0 | 0 | | From | To | Description |
|---|
| 0 | 1 | When value==0, all configuration parameters are configurable. When value==1, all configuration parameters are not configurable.(Locked). |
|
| 255 | Reset to default factory setting | This parameter is used to reset product to default factory setting. (There are just 2 values can be used) | 0 | 4 | 0 | 0 | 0 | | From | To | Description |
|---|
| 0 | 1431655765 | When value==1431655765, it will reset the product to default factory setting and be excluded from Z-wave network. When value==1, it only will reset the all configuration parameters to default setting. The other values will be reserved. |
|
| 3 | Current Overload Protection | This parameter is used for the overload protection, which means the load will be disconnected after 5 seconds when the current more than 39.5A. | 0 | 1 | 0 | 0 | 0 | | From | To | Description |
|---|
| 0 | 1 | 0=disabled, 1=enabled |
|
| 80 | Enable/Disable to send notifications to associated devices to associated devices | This parameter is used to Enable/Disable to send notifications to associated devices (in Group 1) when the state of Heavy Duty Smart Switch Gen5’s load is changed. (0=send nothing, 1=send hail CC, 2=send basic CC report). | 0 | 1 | 0 | 0 | 0 | | From | To | Description |
|---|
| 0 | 2 | (0=nothing, 1=hail CC, 2=basic CC report |
|
| 90 | Enable/Disable the function of parameter 91 and 92 | This parameter is used to Enable/Disable the function of parameter 91 and 92 below (1=Enabled, 0=Disabled). | 0 | 1 | 0 | 0 | 1 | | From | To | Description |
|---|
| 0 | 1 | 0=disabled, 1=enabled |
|
| 91 | Induce an automatic report | This parameter is used to induce an automatic report when the change of the current power is more/less than the threshold in wattage. | 0 | 2 | 0 | 0 | 50 | | From | To | Description |
|---|
| 0 | 60000 | The threshold can be set from 0 to 60000 watt. |
|
| 92 | Induce an automatic report | This parameter is used to induce an automatic report when the change of the current power is more/less than the threshold in percentage. | 0 | 1 | 0 | 0 | 10 | | From | To | Description |
|---|
| 0 | 100 | The threshold can be set from 0 to 100 percent. |
|
| 100 | Set parameter 101~103 to default. | This parameter is used to restore the parameter 101, 102 and 103 to default setting. | 0 | 1 | 0 | 0 | 0 | | From | To | Description |
|---|
| 0 | 1 | When value==1, parameters 101 ~103 will be restored to default setting. When value==0, it will not restore any parameter. |
|
| 110 | Set parameter 111~113 to default. | This parameter is used to restore the parameter 111, 112 and 113 to default setting. | 0 | 1 | 0 | 0 | 0 | | From | To | Description |
|---|
| 0 | 1 | When value==1, parameters 111 ~113 will be restored to default setting. |
|
| 111 | Set the interval time of sending report. | This parameter is used to set the interval time of sending report in Report Group 1. (The unit of time is second). | 0 | 4 | 0 | 0 | 5 | | From | To | Description |
|---|
| 0 | 268435456 | You have a wide range to set the interval time that can be set from 0 to 268435456 seconds. |
|
| 112 | Set the interval time of sending report. | This parameter is used to set the interval time of sending report in Report Group 2. (The unit of time is second). | 0 | 4 | 0 | 0 | 120 | | From | To | Description |
|---|
| 0 | 268435456 | You have a wide range to set the interval time that can be set from 0 to 268435456 seconds. |
|
| 113 | Set the interval time of sending report. | This parameter is used to set the interval time of sending report in Report Group 3. (The unit of time is second). | 0 | 4 | 0 | 0 | 120 | | From | To | Description |
|---|
| 0 | 268435456 | You have a wide range to set the interval time that can be set from 0 to 268435456 seconds. |
|