Product Recognition | |
---|
Certification Number | ZC14-25080540 |
---|
Name | Siren & Chime |
---|
Short Description | Use the Siren & Chime to trigger sound or visual alarm as well as custom tones in home automation and smart security scenarios. |
---|
Description | PRODUCT HIGHLIGHTS:
- Sound and visual Z-Wave® alarm
- Upload custom playback files for chime and siren
- Great for DIY security and alert applications
- Just plug it into a standard receptacle
- Z-Wave® Long Range for an ultra stable network
- Built-in battery for back-up power up to 24 hours
- 800 series Z-Wave® and S2 SmartStart Security
PRODUCT SPECS:
- Model Number: ZSE50 800LR
- Power: 100-120V~, 60Hz
- Max volume: 90 dB
- Max number of playback sounds: 50
- Internal file storage: 16 MB
- Supported file types: mp3, wav
- Z-Wave® Range: Up to 300 feet line of sight (up to 1300 feet with ZWLR)
- Operating Temperature: 32-104° F (0-40° C)
- Installation and Use: Indoor only
- Dimensions: 2.1” x 1.7” x 1.1” |
---|
Brand | Zooz |
---|
Brand Owner | Zooz |
---|
Identifier | ZSE50 800LR |
---|
Product Line | Security |
---|
Product URL | https://www.thesmartesthouse.com/products/zooz-z-wave-long-range-siren-chime-zse50-800lr |
---|
OEM Version | HW: 01 FW: 01.10 |
---|
Hardware Platform | EFR32ZG23A |
---|
Z-Wave Version | 7.18.8 |
---|
Library Type | END_NODE_ENHANCED_232 |
---|
Device Type | Sound Switch DT |
---|
Role Type | ROLE_TYPE_END_NODE_ALWAYS_ON |
---|
Manufacturer ID | 0x027A |
---|
Product Type ID | 0x0004 |
---|
Product ID | 0x0369 |
---|
User Icon | 0x2200 |
---|
Installer Icon | 0x2200 |
---|
Frequency Plans | US: 916.00MHz, 908.40MHz, US_LR: 912.00MHz, 920.00MHz |
---|
Categories | On/Off Switches/Devices, Security Add-Ons |
---|
Countries / Regions | Argentina, Bahamas, Barbados, Bermuda, Bolivia, British Virgin Islands, Canada, Cayman Islands, Colombia, Guatemala, Haiti, Honduras, Jamaica, Mexico, Panama, Saint Kitts and Nevis, Suriname, Trinidad and Tobago, Turks and Caicos Islands, United States of America |
---|
Supported Command Classes | Identifier | Name | Key | Version |
---|
COMMAND_CLASS_ASSOCIATION_V2 | Association V2 | 0x85 | 2 | COMMAND_CLASS_ASSOCIATION_GRP_INFO_V3 | Association Group Information (AGI) V3 | 0x59 | 3 | COMMAND_CLASS_DEVICE_RESET_LOCALLY | Device Reset Locally | 0x5A | 1 | COMMAND_CLASS_FIRMWARE_UPDATE_MD_V5 | Firmware Update Meta Data V5 | 0x7A | 5 | COMMAND_CLASS_INDICATOR_V3 | Indicator V3 | 0x87 | 3 | COMMAND_CLASS_MANUFACTURER_SPECIFIC_V2 | Manufacturer Specific V2 | 0x72 | 2 | COMMAND_CLASS_MULTI_CHANNEL_ASSOCIATION_V3 | Multi Channel Association V3 | 0x8E | 3 | COMMAND_CLASS_VERSION_V3 | Version V3 | 0x86 | 3 | COMMAND_CLASS_ZWAVEPLUS_INFO_V2 | Z-Wave Plus Info V2 | 0x5E | 2 | COMMAND_CLASS_SECURITY_2 | Security 2 | 0x9F | 1 | COMMAND_CLASS_SUPERVISION | Supervision | 0x6C | 1 | COMMAND_CLASS_TRANSPORT_SERVICE_V2 | Transport Service V2 | 0x55 | 2 | COMMAND_CLASS_POWERLEVEL | Powerlevel | 0x73 | 1 | COMMAND_CLASS_SOUND_SWITCH_V2 | Sound Switch V2 | 0x79 | 2 | COMMAND_CLASS_BASIC_V2 | Basic V2 | 0x20 | 2 | COMMAND_CLASS_APPLICATION_STATUS | Application Status | 0x22 | 1 | COMMAND_CLASS_CONFIGURATION_V4 | Configuration V4 | 0x70 | 4 | COMMAND_CLASS_NOTIFICATION_V8 | Notification V8 | 0x71 | 8 | COMMAND_CLASS_BATTERY | Battery | 0x80 | 1 |
|
---|
S2 Classes | S2_AUTHENTICATED, S2_UNAUTHENTICATED |
---|
Documents | |
---|
Features | Feature | Values |
---|
Color | | Firmware Updatable | Value |
---|
Updatable by Consumer by RF |
|
|
---|
Association Groups | Group Number | Maximum Nodes Supported | End Point ID | Group Name | Profile |
---|
1 | 5 | 0 | Lifeline | 0x0001 | 2 | 5 | 0 | On/Off Control | 0x2001 |
|
---|
Configuration Parameters | Parameter Number | Name | Description | Format | Size | Min Value | Max Value | Default Value |
---|
1 | Playback Mode | Set siren playback mode: once (0), loop for x seconds (1), loop x times (2), loop until cancel (3), no sound (4). | 2 | 1 | 0 | 0 | 0x00 | 2 | Playback Duration | Set playback duration for the siren (in seconds) when the siren is in playback mode 1 (param 1). | 1 | 2 | 0 | 0 | 0x00B4 | 3 | Playback Loop Count | Set the number of playback loops for the selected tone when the siren is in playback mode 2 (param 1). | 1 | 1 | 0 | 0 | 0x01 | 4 | Playback Tone | Set the default tone for the siren playback. Choose the number of the file in the library as value. | 1 | 1 | 0 | 0 | 0x09 | 5 | Playback Volume | Set playback volume (0-100, 0-mute). | 1 | 1 | 0 | 0 | 0x64 | 6 | LED Indicator Mode | Set the LED indicator mode for the siren: off (0), strobe (1), police strobe (2), pulse (3), solid on (4). See documentation for details. | 2 | 1 | 0 | 0 | 0x01 | 7 | LED Indicator Color | Set the LED indicator color: red (0), yellow (42), green (85), indigo (127), blue (170), purple (212), or white (255). | 1 | 1 | 0 | 0 | 0x00 | 8 | Low Battery Report | Which % level should the device report low battery to the hub. | 1 | 1 | 0 | 0 | 0x14 | 9 | LED In Back-Up Battery Mode | Set the LED indicator in back-up battery mode: off (0), regular LED mode (1), pulse white for full battery and red for low battery (2). | 2 | 1 | 0 | 0 | 0x01 | 10 | Button Tone Selection | Disable tone selection from physical buttons on the siren (0). Expert users only, see documentation for details. | 2 | 1 | 0 | 0 | 0x01 | 11 | Button Volume Selection | Disable volume adjustment from physical buttons on the siren (0). Expert users only, see documentation for details. | 2 | 1 | 0 | 0 | 0x01 |
|
---|
Texts | ID | Description | Value |
---|
8 | Where to find S2 DSK on product | The SmartStart QR code and security PIN are located on top of the siren so you can easily scan the code when the device is plugged in. | 1 | Classic Inclusion | Initiate inclusion (pairing) in the app or hub UI. Make sure the device is powered and finalize the inclusion at the siren: tap the + button on the device 3 times quickly. | 2 | Classic Exclusion | 1. Bring your siren close to the hub if possible.
2. Put the Z-Wave® hub into exclusion mode
3. Tap the “-” button on the siren 3 times quickly (the LED indicator will start blinking green)
4. Your hub will confirm exclusion, the LED indicator on the siren will turn green for 2 seconds, a message will sound, and the device will be removed. | 5 | Factory Reset Procedure | If your primary controller is missing or inoperable, you may need to reset the device to factory settings.
To reset the relay, hold the + and - buttons together for at least 15 seconds. The LED will turn green after 3 seconds (keep holding the buttons), then start blinking red after 8 seconds, and it will turn solid red after 15 seconds to confirm successful reset. You’ll also hear a confirmation message that the device has been reset.
NOTE: All previously recorded activity and custom settings will be erased from the device’s memory. |
|
---|
Supported Notification Types | Notification Type | Event / State |
---|
Power Management | Mains status: AC mains disconnected | Power Management | Mains status: AC mains re-connected | Siren | Siren status: Siren active |
|
---|
Supports NWI | Yes |
---|
Supports Explorer Frames | Yes |
---|
Supports SmartStart | Yes |
---|