| Product Recognition | |
|---|
| Certification Number | ZC14-26010578 |
|---|
| Name | Yale Pro® 2 Mortise Lock with Z-Wave |
|---|
| Short Description | The Yale Pro® 2 Mortise Lock is the smart keypad upgrade to traditional mortise locks, delivering keyless access for high-traffic entryways in apartments and multi-family buildings like common shared spaces. While residents and guests enjoy seamless keyless entry, property owners gain peace of mind with a lock built for durability and enhanced high security. |
|---|
| Description | The Yale Pro® 2 Line of smart keypad locks delivers the industry’s most flexible solution for apartment and multi-family units including gyms and shared spaces. Built on the award-winning residential Yale Assure Lock® 2 design, it pairs modern aesthetics with years of reliable convenience and security. From interconnected to mortise, each lock in the suite is designed to meet diverse hardware and security requirements. For flexible connectivity, the locks integrate across multiple smart security systems and platforms, allowing providers to be swapped in or out as property needs evolve. And by eliminating physical keys, the Pro 2 line creates a truly unified, fully integrated access experience for property managers, residents, and guests alike. |
|---|
| Brand | Yale |
|---|
| Brand Owner | Fortune Brands Innovations, Inc. |
|---|
| Identifier | YMM614-ZW4 |
|---|
| Product Line | Yale Pro® 2 |
|---|
| OEM Version | HW: 01 FW: 05.01:23.12 |
|---|
| Hardware Platform | ZGM230SB |
|---|
| Z-Wave Version | 7.23.2 |
|---|
| Library Type | END_NODE_ENHANCED_232 |
|---|
| Device Type | Lock DT |
|---|
| Role Type | ROLE_TYPE_END_NODE_SLEEPING_LISTENING |
|---|
| Manufacturer ID | 0x0463 |
|---|
| Product Type ID | 0x8121 |
|---|
| Product ID | 0x8A4A |
|---|
| User Icon | 0x0300 |
|---|
| Installer Icon | 0x0300 |
|---|
| Radio Range Z-Wave (m) | 40 |
|---|
| Radio Range Z-Wave LR (m) | 400 |
|---|
| Frequency Plans | US: 916.00MHz, 908.40MHz, US_LR: 912.00MHz, 920.00MHz |
|---|
| Categories | Locks |
|---|
| Countries / Regions | Canada, United States of America |
|---|
| Supported Command Classes | | Identifier | Name | Key | Version |
|---|
| COMMAND_CLASS_BASIC_V2 | Basic V2 | 0x20 | 2 | | COMMAND_CLASS_CONFIGURATION_V4 | Configuration V4 | 0x70 | 4 | | COMMAND_CLASS_DOOR_LOCK_V4 | Door Lock V4 | 0x62 | 4 | | COMMAND_CLASS_DOOR_LOCK_LOGGING | Door Lock Logging | 0x4C | 1 | | COMMAND_CLASS_NOTIFICATION_V8 | Notification V8 | 0x71 | 8 | | COMMAND_CLASS_SCHEDULE_ENTRY_LOCK_V3 | Schedule Entry Lock V3 | 0x4E | 3 | | COMMAND_CLASS_USER_CODE_V2 | User Code V2 | 0x63 | 2 | | COMMAND_CLASS_USER_CREDENTIAL | User Credential | 0x83 | 1 | | COMMAND_CLASS_APPLICATION_STATUS | Application Status | 0x22 | 1 | | COMMAND_CLASS_ASSOCIATION_V2 | Association V2 | 0x85 | 2 | | COMMAND_CLASS_ASSOCIATION_GRP_INFO_V3 | Association Group Information (AGI) V3 | 0x59 | 3 | | COMMAND_CLASS_BATTERY | Battery | 0x80 | 1 | | COMMAND_CLASS_DEVICE_RESET_LOCALLY | Device Reset Locally | 0x5A | 1 | | COMMAND_CLASS_FIRMWARE_UPDATE_MD_V5 | Firmware Update Meta Data V5 | 0x7A | 5 | | COMMAND_CLASS_INDICATOR_V3 | Indicator V3 | 0x87 | 3 | | COMMAND_CLASS_MANUFACTURER_SPECIFIC_V2 | Manufacturer Specific V2 | 0x72 | 2 | | COMMAND_CLASS_MULTI_CHANNEL_ASSOCIATION_V3 | Multi Channel Association V3 | 0x8E | 3 | | COMMAND_CLASS_TIME_V2 | Time V2 | 0x8A | 2 | | COMMAND_CLASS_TIME_PARAMETERS | Time Parameters | 0x8B | 1 | | COMMAND_CLASS_VERSION_V3 | Version V3 | 0x86 | 3 | | COMMAND_CLASS_ZWAVEPLUS_INFO_V2 | Z-Wave Plus Info V2 | 0x5E | 2 | | COMMAND_CLASS_SECURITY | Security 0 | 0x98 | 1 | | COMMAND_CLASS_SECURITY_2 | Security 2 | 0x9F | 1 | | COMMAND_CLASS_SUPERVISION | Supervision | 0x6C | 1 | | COMMAND_CLASS_TRANSPORT_SERVICE_V2 | Transport Service V2 | 0x55 | 2 | | COMMAND_CLASS_POWERLEVEL | Powerlevel | 0x73 | 1 |
|
|---|
| S2 Classes | S2_ACCESS_CONTROL |
|---|
| Documents | |
|---|
| Features | | Feature | Values |
|---|
| Door Lock Type | | Value |
|---|
| Electro-Magnetic Fail Closed |
|
|
|---|
| Association Groups | | Group Number | Maximum Nodes Supported | End Point ID | Group Name | Profile |
|---|
| 1 | 5 | 0 | Lifeline | 0x0001 |
|
|---|
| Configuration Parameters | | Parameter Number | Name | Description | Format | Size | Min Value | Max Value | Default Value |
|---|
| 1 | Volume | Set Volume Level to high (1), low (2), or silent (3). | 1 | 1 | 0 | 0 | 0x01 | | 2 | Auto Relock | Set Auto Relock feature to enable or disable. | 1 | 1 | 0 | 0 | 0x00 | | 3 | Relock time | Adjust the time your lock will auto relock. | 1 | 1 | 0 | 0 | 0x03 | | 4 | Wrong Code Entry Limit | Adjust the limit for wrong code entries allowed by your lock. | 1 | 1 | 0 | 0 | 0x03 | | 7 | Shut down time | Adjust the time your lock is shutdown after reaching its wrong code entry limit. | 1 | 1 | 0 | 0 | 0x3C | | 8 | Operating mode | Set the Operating Mode to normal mode, keypad disable mode, privacy mode or passage mode. | 1 | 1 | 0 | 0 | 0x00 | | 11 | One Touch Locking | Set One Touch Locking feature to enable or disable. | 1 | 1 | 0 | 0 | 0xFF | | 23 | Lock Body Alarms Mask | Set Lock Body Sensors: DPS, Deadbolt, and Lever Rotate to receive Door Lock Status alerts | 3 | 1 | 0 | 0 | 0xFF |
|
|---|
| Texts | | ID | Description | Value |
|---|
| 8 | Where to find S2 DSK on product | 1. Install the Smart Module into the slot above the battery compartment
IMPORTANT: The batteries must be removed before removing the Smart Module:
• Remove battery cover
• Remove batteries
• Insert or remove Smart Module
• Reinstall batteries
• Reinstall battery cover
2. Open the Z-Wave system's smart home or alarm app on your smartphone or tablet
3. Follow the in-app instructions for adding a new device
4. On your lock keypad, enter your master entry code followed by the gear icon
5. Press the 7 key followed by the gear icon
6. Press the 1 key followed by the gear icon | | 1 | Classic Inclusion | • Enter the 4–8-digit Programming PIN code followed by the gear key.
• Press the 7 key followed by the gear key.
• Press the 1 key followed by the gear key.
• Scan the QR code, if prompted, or…
• Enter the first five (5) digits of the DSK if prompted. | | 2 | Classic Exclusion | • Enter the 4–8-digit Programming PIN code followed by the gear key.
• Press the 7 key followed by the gear key.
• Press the 3 key followed by the gear key. | | 5 | Factory Reset Procedure | 1. Open the battery cover and remove one battery.
2. Uninstall the battery box.
3. Press and hold the reset pin.
4. While holding the reset pin, re-insert the removed battery.
5. Keep holding the reset pin for 5 more seconds until the keypad digits illuminate.
6. Re-install the battery box. |
|
|---|
| Supported Notification Types | | Notification Type | Event / State |
|---|
| Access Control | Manual lock operation | | Access Control | Manual unlock operation | | Access Control | RF lock operation | | Access Control | RF unlock operation | | Access Control | Keypad lock operation | | Access Control | Keypad unlock operation | | Access Control | Auto lock locked operation | | Access Control | Lock state: Lock jammed | | Access Control | All user codes deleted | | Access Control | Single user code deleted | | Access Control | New user code added | | Access Control | New user code not added due to duplicate code | | Access Control | Keypad state: Keypad temporary disabled | | Access Control | New program code entered : unique code for lock configuration | | Access Control | Door state: Window/door is open | | Access Control | Door state: Window/door is closed | | Access Control | Messaging User Code entered via keypad | | 0x06 | 0x21 | | 0x06 | 0x22 | | 0x06 | 0x23 | | 0x06 | 0x24 | | 0x06 | 0x2F | | 0x06 | 0x33 | | 0x06 | 0x30 | | 0x06 | 0x32 | | Power Management | Power status: Power has been applied | | Power Management | Battery maintenance status: Replace battery soon | | Power Management | Battery maintenance status: Replace battery now | | Power Management | Battery level status: Battery is fully charged | | System | Cover status: Tampering, product cover removed |
|
|---|
| Supports NWI | Yes |
|---|
| Supports Explorer Frames | Yes |
|---|
| Is Flirs | Yes |
|---|
| Supports SmartStart | Yes |
|---|