Product Recognition | |
---|
Certification Number | ZC10-15060028 |
---|
Name | Z-Wave Doorbell Sensor |
---|
Short Description | The DB100Z is a voltage sensing device that sends out a Notification report when voltage is detected at the sensor inputs. |
---|
Long Description | The DB100Z is a battery powered, voltage sensing device that sends out a Notification report when voltage is detected at the sensor inputs. |
---|
Brand | Ingersoll Rand - Nexia Home Intelligence |
---|
Product Identifier | DB100Z |
---|
OEM Version | 01 |
---|
Hardware Platform | ZM5202 |
---|
Z-Wave Version | 6.51.06 |
---|
Library Type | SLAVE_ENHANCED_232 |
---|
Device Type | Notification Sensor |
---|
Role Type | ROLE_TYPE_SLAVE_SLEEPING_REPORTING |
---|
Manufacturer ID | 0x0178 |
---|
Product Type ID | 0x4442 |
---|
Product ID | 0x3130 |
---|
Frequency Plans | US: 916.00MHz, 908.40MHz |
---|
Categories | Sensors |
---|
Countries / Regions | United States of America |
---|
Documents | |
---|
Association Groups | Group Number | Maximum Nodes Supported | End Point ID | Description |
---|
1 | 5 | 0 | Z-Wave Plus Lifeline
Battery Report, Notification Report, Device Reset Locally Notification |
|
---|
Configuration Parameters | Parameter Number | Name | Description | Format | Size | Min Value | Max Value | Default Value | Parameter Values |
---|
1 | Send Battery Report with Notification Report | This setting determines whether the battery level report will be sent when the notification report is sent by the device. | 0 | 1 | 0 | 0 | 1 | From | To | Description |
---|
1 | 1 | Send with the Notification Report | 0 | 0 | Do not send with the Notification Report |
|
|
---|
Texts | ID | Description | Value |
---|
2 | Exclusion | 1. Set primary controller to Exclude mode
2. Press the Install Button | 4 | Device Wake-Up | When the Install Button is triple-pressed, the device will send a Wakeup Notification report and stay awake for 10 seconds.
WAKEUP_INTERVAL_CAPABILITIES_REPORT
Min Wake Up Interval :60 seconds
Max Wake Up Interval: 86400 seconds
Default Wake Up Interval: 25200 seconds
Wake Up Interval Step: 60 | 1 | Inclusion | 1. Set primary controller to Include mode
2. Press the Install Button | 5 | Factory Reset | Please only perform a factory reset when the primary controller is missing or inoperable. A factory reset will remove all network settings and configurations.
1. Hold down Install Button for 10 seconds
2. Release the Install Button
3. When the Status LED begins to blink, the unit has finished restoring configuration |
|
---|
Supports NWI | Yes |
---|