3 | Set the PIR time. | The default PIR time is 4 minutes. The Multisensor will send BASIC SET CC (0x00) to the associated nodes if no motion is triggered again in 4 minutes. | 0 | 2 | 0 | 0 | 240 | From | To | Description |
---|
10 | 3600 | The range of PIR time is 10 to 3600. |
|
4 | Set the sensitivity of the motion sensor. | This parameter changes the sensitivity level of the motion detector. | 0 | 1 | 0 | 0 | 5 | From | To | Description |
---|
1 | 1 | Sensitivity Level 1 of 6 | 5 | 5 | Maximum Sensitivity | 0 | 0 | Minimum Sensitivity | 4 | 4 | Sensitivity Level 5 of 6 | 2 | 2 | Sensitivity Level 2 of 6 | 3 | 3 | Sensitivity Level 3 of 6 |
|
5 | Which command would be sent when the motion sensor triggered. | To set which command would be sent when the motion sensor triggered. | 0 | 1 | 0 | 0 | 1 | From | To | Description |
---|
2 | 2 | Send Sensor Binary Report CC | 1 | 1 | Send Basic Set CC |
|
2 | Enable/Disable waking up for 10 minutes when re-power on (battery mode) the MultiSensor. | Enable/Disable waking up for 10 minutes when re-power on (battery mode) the MultiSensor. | 0 | 1 | 0 | 0 | 0 | From | To | Description |
---|
0 | 0 | Disable | 1 | 1 | Enable. |
|
9 | Report the current power mode and the product state for battery power mode | Report the current power mode and the product state for battery power mode. Note: this parameter cannot be used as Set usage. | 0 | 2 | 0 | 0 | 0 | From | To | Description |
---|
257 | 257 | Keep awake for 10 minutes for battery power mode. | 256 | 256 | Keep sleep state for Battery power mode | 0 | 0 | USB power mode |
|
40 | Enable/disable the selective reporting only when measurements reach a certain threshold or percentage | Enable/disable the selective reporting only when measurements reach a certain threshold or percentage. This is used to reduce network traffic. Note: If USB power, the Sensor will check the threshold every 10 seconds. If battery power, the Sensor will check the threshold when it is waken up. | 0 | 1 | 0 | 0 | 0 | From | To | Description |
---|
0 | 0 | Disable | 1 | 1 | Enable. |
|
42 | Threshold change in humidity to induce an automatic report | Threshold change in humidity to induce an automatic report. Note: 1. The unit is %. 2. The default value is 10, which means that if the current humidity gap is more than 10%, it will send out a humidity report. | 0 | 1 | 0 | 0 | 10 | From | To | Description |
---|
1 | 100 | Available rang is 1% to 100%. |
|
43 | Threshold change in luminance to induce an automatic report. | Threshold change in luminance to induce an automatic report. | 0 | 2 | 0 | 0 | 100 | From | To | Description |
---|
1 | 30000 | Available rang is 1 LUX to 30000 LUX. |
|
44 | Threshold change in battery level to induce an automatic report. | Threshold change in battery level to induce an automatic report. Note: 1. The unit is %. 2. The default value is 10, which means that if the current battery level gap is more than 10%, it will send out a battery report. | 0 | 1 | 0 | 0 | 10 | From | To | Description |
---|
1 | 100 | Available rang is 1% to 100%. |
|
45 | Threshold change in ultraviolet to induce an automatic report. | Threshold change in ultraviolet to induce an automatic report. | 0 | 1 | 0 | 0 | 2 | From | To | Description |
---|
1 | 11 | Available rang is 1 to 11. |
|
46 | Enable/disable to send the alarm report of low temperature | Enable/disable to send the alarm report of low temperature(<-15℃). Note: If it is enabled, the MultiSensor will send a report of Multi Level Temperature CC to controller when the current temperature is less than -15℃). | 0 | 1 | 0 | 0 | 0 | From | To | Description |
---|
1 | 1 | Enable. | 0 | 0 | Disable | 1 | 30000 | Available rang is 1LUX to 30000LUX. |
|
48 | Enable/disable to send a report when the measurement is more than the upper limit value or less than the lower limit value. | Enable/disable to send a report when the measurement is more than the upper limit value or less than the lower limit value. | 0 | 1 | 0 | 0 | 0 | From | To | Description |
---|
0 | 0 | Disable | 1 | 1 | Enable. |
|
49 | Set the upper limit value of temperature sensor. | Set the upper limit value of temperature sensor. When the measurement is more than this upper limit, which will trigger to sent out a sensor report. | 0 | 4 | 0 | 0 | 824 | From | To | Description |
---|
-400 | 2120 | Available rang is -40.0℉ to 212.0℉. |
|
50 | Set the lower limit value of temperature sensor. | Set the lower limit value of temperature sensor. When the measurement is less than this lower limit, which will trigger to sent out a sensor report. High byte is the lower limit value. | 0 | 4 | 0 | 0 | 320 | From | To | Description |
---|
-400 | 2120 | Available rang is -40.0℉ to 212.0℉. |
|
51 | Set the upper limit value of humidity sensor. | Set the upper limit value of humidity sensor. when the measurement is more than this upper limit, which will trigger to sent out a sensor report. | 0 | 1 | 0 | 0 | 60 | From | To | Description |
---|
0 | 100 | Available rang is 0% to 100%. |
|
52 | Set the lower limit value of humidity sensor. | Set the lower limit value of humidity sensor. When the measurement is less than this lower limit, which will trigger to sent out a sensor report. | 0 | 1 | 0 | 0 | 50 | From | To | Description |
---|
0 | 100 | Available rang is 0% to 100%. |
|
53 | Set the upper limit value of Lighting sensor | Set the upper limit value of Lighting sensor. When the measurement is more than this upper limit, which will trigger to sent out a sensor report. | 0 | 1 | 0 | 0 | 1000 | From | To | Description |
---|
0 | 30000 | Available rang is 0 to 30000LUX. |
|
54 | Set the lower limit value of Lighting sensor. | Set the lower limit value of Lighting sensor. When the measurement is less than this lower limit, which will trigger to sent out a sensor report. | 0 | 1 | 0 | 0 | 100 | From | To | Description |
---|
0 | 30000 | Available rang is 0 to 30000LUX. |
|
55 | Set the upper limit value of ultraviolet sensor. | Set the upper limit value of ultraviolet sensor. When the measurement is more than this upper limit, which will trigger to sent out a sensor report. | 0 | 1 | 0 | 0 | 8 | From | To | Description |
---|
1 | 11 | Available rang is 1 to 11. |
|
56 | Set the lower limit value of ultraviolet sensor. | Set the lower limit value of ultraviolet sensor. When the measurement is less than this upper limit, which will trigger to sent out a sensor report. | 0 | 1 | 0 | 0 | 4 | From | To | Description |
---|
1 | 11 | Available rang is 1 to 11. |
|
113 | To set the interval time of sending reports in Report group 3 | To set the interval time of sending reports in Report group 3 | 0 | 4 | 0 | 0 | 3600 | From | To | Description |
---|
5 | 2678400 | Available rang is 5 to 2678400 seconds. |
|
58 | Set the recover limit value of humidity sensor. | Set the recover limit value of humidity sensor. Note: 1. When the current measurement <= (Upper limit – Recover limit), the upper limit report is enabled and then it would send out a sensor report when the next measurement is more than the upper limit. After that the upper limit report would be disabled again until the measurement = (Lower limit + Recover limit), the lower limit report is enabled and then it would send out a sensor report when the next measurement is less than the lower limit. After that the lower limit report would be disabled again until the measurement >= (Lower limit + Recover limit). | 0 | 1 | 0 | 0 | 5 | From | To | Description |
---|
1 | 50 | Available rang is 1 to 50% |
|
59 | Set the recover limit value of Lighting sensor. | Set the recover limit value of Lighting sensor. Note: 1. When the current measurement <= (Upper limit – Recover limit), the upper limit report is enabled and then it would send out a sensor report when the next measurement is more than the upper limit. After that the upper limit report would be disabled again until the measurement = (Lower limit + Recover limit), the lower limit report is enabled and then it would send out a sensor report when the next measurement is less than the lower limit. After that the lower limit report would be disabled again until the measurement >= (Lower limit + Recover limit). 3. Unit = 10×Recover limit (Lux) | 0 | 1 | 0 | 0 | 100 | From | To | Description |
---|
1 | 127 | Available rang is 10Lux to 1270Lux |
|
60 | Set the recover limit value of Ultraviolet sensor. | Set the recover limit value of Ultraviolet sensor. Note: 1. When the current measurement <= (Upper limit – Recover limit), the upper limit report is enabled and then it would send out a sensor report when the next measurement is more than the upper limit. After that the upper limit report would be disabled again until the measurement = (Lower limit + Recover limit), the lower limit report is enabled and then it would send out a sensor report when the next measurement is less than the lower limit. After that the lower limit report would be disabled again until the measurement >= (Lower limit + Recover limit). | 0 | 1 | 0 | 0 | 2 | From | To | Description |
---|
0 | 0 | USB power mode | 256 | 256 | Keep sleep state for Battery power mode | 257 | 257 | Keep awake for 10 minutes for battery power mode. | 1 | 5 | Available rang is 1 to 5. |
|
64 | Set the default unit of the automatic temperature report in parameter 101-103. | Set the default unit of the automatic temperature report in parameter 101-103. | 0 | 1 | 0 | 0 | 2 | From | To | Description |
---|
2 | 2 | The unit is Fahrenheit. | 1 | 1 | The unit is Celsius. |
|
81 | Enable/disable the LED blinking when the PIR is triggered. | Enable/disable the LED blinking when the PIR is triggered. | 0 | 1 | 0 | 0 | 0 | From | To | Description |
---|
1 | 1 | Disable | 0 | 0 | Enable. |
|
100 | Set the parameter 101-103 to default values. | Set the parameter 101-103 to default values. | 0 | 1 | 0 | 0 | 0 | From | To | Description |
---|
1 | 1 | Set the parameter 101-103 to default values. |
|
111 | To set the interval time of sending reports in Report group 1 | To set the interval time of sending reports in Report group 1 | 0 | 4 | 0 | 0 | 3600 | From | To | Description |
---|
5 | 2678400 | Available rang is 5 to 2678400 seconds. |
|
112 | To set the interval time of sending reports in Report group 2 | To set the interval time of sending reports in Report group 2 | 0 | 4 | 0 | 0 | 3600 | From | To | Description |
---|
5 | 2678400 | Available rang is 5 to 2678400 seconds. |
|
201 | Temperature sensor calibration | Temperature sensor calibration. Note: 1. High byte is the calibration value. Low byte is the unit (0x01=Celsius, 0x02=Fahrenheit) 2. The calibration value (high byte) contains one decimal point. E.g. if the value is set to 20 (0x1401), the calibration value is 2.0 ℃ (EU/AU version) or if the value is set to 20 (0x1402), the calibration value is 2.0 ℉(US version) 3. The calibration value (high byte) = standard value - measure value. E.g. If measure value =25.3℃ and the standard value = 23.2℃, so the calibration value= 23.2℃ - 25.3℃= -2.1℃ (0xEB). If the measure value =30.1℃ and the standard value = 33.2℃, so the calibration value= 33.2℃ - 30.1℃=3.1℃ (0x1F). | 0 | 2 | 0 | 0 | 0 | From | To | Description |
---|
-128 | 127 | Available rang is -12.8℃ to 12.7℃. |
|
203 | Luminance sensor calibration | Luminance sensor calibration. The calibration value = standard value - measure value. E.g. If measure value =800Lux and the standard value = 750Lux, so the calibration value= 750 – 800= -50 (0xFFCE). If the measure value =850Lux and the standard value = 900Lux, so the calibration value= 900 – 850=50 (0x0032) | 0 | 2 | 0 | 0 | 0 | From | To | Description |
---|
-1000 | 1000 | Available rang is -1000Lux to 1000Lux. |
|
204 | Ultraviolet sensor calibration | Ultraviolet sensor calibration. The calibration value = standard value - measure value. E.g. If measure value =9 and the standard value = 8, so the calibration value= 8 – 9= -1 (0xFE). If the measure value =7 and the standard value = 9, so the calibration value= 9 – 7=2 (0x02). | 0 | 1 | 0 | 0 | 0 | From | To | Description |
---|
-10 | 10 | Available rang is -10 to 10. |
|
202 | Humidity sensor calibration | Humidity sensor calibration. The calibration value = standard value - measure value. E.g. If measure value =80RH and the standard value = 75RH, so the calibration value= 75RH – 80RH= -5RH (0xFB). If the measure value =85RH and the standard value = 90RH, so the calibration value= 90RH – 85RH=5RH (0x05). | 0 | 1 | 0 | 0 | 0 | From | To | Description |
---|
-50 | 50 | Available rang is -50RH to 50RH. |
|
252 | Enable/disable all configuration parameters to be locked | Enable/disable all configuration parameters to be locked. | 0 | 1 | 0 | 0 | 0 | From | To | Description |
---|
0 | 0 | Disable | 1 | 1 | Enable. |
|
255 | Reset to factory defaults. | Reset to factory defaults. | 0 | 4 | 0 | 0 | 0 | From | To | Description |
---|
1 | 1 | Reset all configuration parameters to factory defaults. | 1431655765 | 1431655765 | Reset the product to factory defaults. |
|