2 | Enable/Disable waking up for 10 minutes when re-power on (battery mode) the MultiSensor. | Enable/Disable waking up for 10 minutes when re-power on (battery mode) the MultiSensor. | 0 | 1 | 0 | 0 | 0 | From | To | Description |
---|
0 | 0 | Disable | 1 | 1 | Enable. |
|
3 | Set the PIR time. | The default PIR time is 4 minutes. The Multisensor will send BASIC SET CC (0x00) to the associated nodes if no motion is triggered again in 4 minutes. | 0 | 2 | 0 | 0 | 240 | From | To | Description |
---|
10 | 3600 | The range of PIR time is 10 to 3600. |
|
4 | Set the sensitivity of the motion sensor. | This parameter changes the sensitivity level of the motion detector. | 0 | 1 | 0 | 0 | 5 | From | To | Description |
---|
2 | 2 | Send Sensor Binary Report CC | 1 | 1 | Sensitivity Level 1 of 6 | 1 | 1 | Send Basic Set CC | 5 | 5 | Maximum Sensitivity | 0 | 0 | Minimum Sensitivity | 4 | 4 | Sensitivity Level 5 of 6 | 2 | 2 | Sensitivity Level 2 of 6 | 3 | 3 | Sensitivity Level 3 of 6 |
|
5 | Which command would be sent when the motion sensor triggered. | To set which command would be sent when the motion sensor triggered. | 0 | 1 | 0 | 0 | 1 | From | To | Description |
---|
2 | 2 | Send Sensor Binary Report CC | 1 | 1 | Send Basic Set CC |
|
9 | Report the current power mode and the product state for battery power mode | Report the current power mode and the product state for battery power mode. Note: this parameter cannot be used as Set usage. | 0 | 2 | 0 | 0 | 0 | |
40 | Enable/disable the selective reporting only when measurements reach a certain threshold or percentage | Enable/disable the selective reporting only when measurements reach a certain threshold or percentage. This is used to reduce network traffic. Note: If USB power, the Sensor will check the threshold every 10 seconds. If battery power, the Sensor will check the threshold when it is waken up. | 0 | 1 | 0 | 0 | 0 | From | To | Description |
---|
0 | 0 | Disable | 1 | 100 | Available rang is 1% to 100%. | 1 | 1 | Enable. |
|
42 | Threshold change in humidity to induce an automatic report | Threshold change in humidity to induce an automatic report. Note: 1. The unit is %. 2. The default value is 10, which means that if the current humidity gap is more than 10%, it will send out a humidity report. | 0 | 1 | 0 | 0 | 10 | From | To | Description |
---|
1 | 100 | Available rang is 1% to 100%. | 1 | 100 | Available rang is 1% to 100%. |
|
43 | Threshold change in luminance to induce an automatic report. | Threshold change in luminance to induce an automatic report. | 0 | 2 | 0 | 0 | 100 | From | To | Description |
---|
1 | 30000 | Available rang is 1 LUX to 30000 LUX. | 1 | 11 | Available rang is 1 to 11. |
|
44 | Threshold change in battery level to induce an automatic report. | Threshold change in battery level to induce an automatic report. Note: 1. The unit is %. 2. The default value is 10, which means that if the current battery level gap is more than 10%, it will send out a battery report. | 0 | 1 | 0 | 0 | 10 | |
45 | Threshold change in ultraviolet to induce an automatic report. | Threshold change in ultraviolet to induce an automatic report. | 0 | 1 | 0 | 0 | 2 | From | To | Description |
---|
1 | 11 | Available rang is 1 to 11. |
|
46 | Enable/disable to send the alarm report of low temperature | Enable/disable to send the alarm report of low temperature(<-15℃). Note: If it is enabled, the MultiSensor will send a report of Multi Level Temperature CC to controller when the current temperature is less than -15℃). | 0 | 1 | 0 | 0 | 0 | From | To | Description |
---|
1 | 1 | Enable. | 0 | 0 | Disable | 1 | 30000 | Available rang is 1LUX to 30000LUX. |
|
48 | Enable/disable to send a report when the measurement is more than the upper limit value or less than the lower limit value. | Enable/disable to send a report when the measurement is more than the upper limit value or less than the lower limit value. | 0 | 1 | 0 | 0 | 0 | |
49 | Set the upper limit value of temperature sensor. | Set the upper limit value of temperature sensor. When the measurement is more than this upper limit, which will trigger to sent out a sensor report. | 0 | 4 | 0 | 0 | 824 | From | To | Description |
---|
-400 | 2120 | Available rang is -40.0℉ to 212.0℉. | -400 | 2120 | Available rang is -40.0℉ to 212.0℉. |
|
50 | Set the lower limit value of temperature sensor. | Set the lower limit value of temperature sensor. When the measurement is less than this lower limit, which will trigger to sent out a sensor report. High byte is the lower limit value. | 0 | 4 | 0 | 0 | 320 | From | To | Description |
---|
0 | 100 | Available rang is 0% to 100%. | -400 | 2120 | Available rang is -40.0℉ to 212.0℉. |
|
51 | Set the upper limit value of humidity sensor. | Set the upper limit value of humidity sensor. when the measurement is more than this upper limit, which will trigger to sent out a sensor report. | 0 | 1 | 0 | 0 | 60 | |
52 | Set the lower limit value of humidity sensor. | Set the lower limit value of humidity sensor. When the measurement is less than this lower limit, which will trigger to sent out a sensor report. | 0 | 1 | 0 | 0 | 50 | |
53 | Set the upper limit value of Lighting sensor | Set the upper limit value of Lighting sensor. When the measurement is more than this upper limit, which will trigger to sent out a sensor report. | 0 | 1 | 0 | 0 | 1000 | From | To | Description |
---|
0 | 30000 | Available rang is 0 to 30000LUX. |
|
54 | Set the lower limit value of Lighting sensor. | Set the lower limit value of Lighting sensor. When the measurement is less than this lower limit, which will trigger to sent out a sensor report. | 0 | 1 | 0 | 0 | 100 | From | To | Description |
---|
0 | 30000 | Available rang is 0 to 30000LUX. |
|
55 | Set the upper limit value of ultraviolet sensor. | Set the upper limit value of ultraviolet sensor. When the measurement is more than this upper limit, which will trigger to sent out a sensor report. | 0 | 1 | 0 | 0 | 8 | From | To | Description |
---|
1 | 11 | Available rang is 1 to 11. |
|
56 | Set the lower limit value of ultraviolet sensor. | Set the lower limit value of ultraviolet sensor. When the measurement is less than this upper limit, which will trigger to sent out a sensor report. | 0 | 1 | 0 | 0 | 4 | From | To | Description |
---|
1 | 11 | Available rang is 1 to 11. |
|
58 | Set the recover limit value of humidity sensor. | Set the recover limit value of humidity sensor. Note: 1. When the current measurement <= (Upper limit – Recover limit), the upper limit report is enabled and then it would send out a sensor report when the next measurement is more than the upper limit. After that the upper limit report would be disabled again until the measurement = (Lower limit + Recover limit), the lower limit report is enabled and then it would send out a sensor report when the next measurement is less than the lower limit. After that the lower limit report would be disabled again until the measurement >= (Lower limit + Recover limit). | 0 | 1 | 0 | 0 | 5 | From | To | Description |
---|
1 | 50 | Available rang is 1 to 50% | 1 | 50 | Available rang is 1 to 50% |
|
59 | Set the recover limit value of Lighting sensor. | Set the recover limit value of Lighting sensor. Note: 1. When the current measurement <= (Upper limit – Recover limit), the upper limit report is enabled and then it would send out a sensor report when the next measurement is more than the upper limit. After that the upper limit report would be disabled again until the measurement = (Lower limit + Recover limit), the lower limit report is enabled and then it would send out a sensor report when the next measurement is less than the lower limit. After that the lower limit report would be disabled again until the measurement >= (Lower limit + Recover limit). 3. Unit = 10×Recover limit (Lux) | 0 | 1 | 0 | 0 | 100 | |
60 | Set the recover limit value of Ultraviolet sensor. | Set the recover limit value of Ultraviolet sensor. Note: 1. When the current measurement <= (Upper limit – Recover limit), the upper limit report is enabled and then it would send out a sensor report when the next measurement is more than the upper limit. After that the upper limit report would be disabled again until the measurement = (Lower limit + Recover limit), the lower limit report is enabled and then it would send out a sensor report when the next measurement is less than the lower limit. After that the lower limit report would be disabled again until the measurement >= (Lower limit + Recover limit). | 0 | 1 | 0 | 0 | 2 | |
64 | Set the default unit of the automatic temperature report in parameter 101-103. | Set the default unit of the automatic temperature report in parameter 101-103. | 0 | 1 | 0 | 0 | 2 | From | To | Description |
---|
2 | 2 | The unit is Fahrenheit. | 1 | 1 | The unit is Celsius. |
|
81 | Enable/disable the LED blinking when the PIR is triggered. | Enable/disable the LED blinking when the PIR is triggered. | 0 | 1 | 0 | 0 | 0 | From | To | Description |
---|
1 | 1 | Disable | 0 | 0 | Enable. | 2 | 2 | The unit is Fahrenheit. | 1 | 1 | The unit is Celsius. |
|
100 | Set the parameter 101-103 to default values. | Set the parameter 101-103 to default values. | 0 | 1 | 0 | 0 | 0 | From | To | Description |
---|
1 | 1 | Set the parameter 101-103 to default values. | 1 | 1 | Disable | 0 | 0 | Enable. |
|
102 | To set which report would be sent in Report group 2 | To set which report would be sent in Report group 2. Note: You can also set all sensor reports to be sent out at the same time. E.g. If you want the batter report and temperature report to be sent out at the same time, you just need to set the configuration value to 33 (1+32). | 0 | 4 | 0 | 0 | 0 | |
103 | To set which report would be sent in Report group 3 | To set which report would be sent in Report group 3. Note: You can also set all sensor reports to be sent out at the same time. E.g. If you want the batter report and temperature report to be sent out at the same time, you just need to set the configuration value to 33 (1+32). | 0 | 4 | 0 | 0 | 0 | |
112 | To set the interval time of sending reports in Report group 2 | To set the interval time of sending reports in Report group 2 | 0 | 4 | 0 | 0 | 3600 | From | To | Description |
---|
5 | 2678400 | Available rang is 5 to 2678400 seconds. |
|
113 | To set the interval time of sending reports in Report group 3 | To set the interval time of sending reports in Report group 3 | 0 | 4 | 0 | 0 | 3600 | From | To | Description |
---|
5 | 2678400 | Available rang is 5 to 2678400 seconds. |
|
201 | Temperature sensor calibration | Temperature sensor calibration. Note: 1. High byte is the calibration value. Low byte is the unit (0x01=Celsius, 0x02=Fahrenheit) 2. The calibration value (high byte) contains one decimal point. E.g. if the value is set to 20 (0x1401), the calibration value is 2.0 ℃ (EU/AU version) or if the value is set to 20 (0x1402), the calibration value is 2.0 ℉(US version) 3. The calibration value (high byte) = standard value - measure value. E.g. If measure value =25.3℃ and the standard value = 23.2℃, so the calibration value= 23.2℃ - 25.3℃= -2.1℃ (0xEB). If the measure value =30.1℃ and the standard value = 33.2℃, so the calibration value= 33.2℃ - 30.1℃=3.1℃ (0x1F). | 0 | 2 | 0 | 0 | 0 | |
202 | Humidity sensor calibration | Humidity sensor calibration. The calibration value = standard value - measure value. E.g. If measure value =80RH and the standard value = 75RH, so the calibration value= 75RH – 80RH= -5RH (0xFB). If the measure value =85RH and the standard value = 90RH, so the calibration value= 90RH – 85RH=5RH (0x05). | 0 | 1 | 0 | 0 | 0 | From | To | Description |
---|
-50 | 50 | Available rang is -50RH to 50RH. |
|
203 | Luminance sensor calibration | Luminance sensor calibration. The calibration value = standard value - measure value. E.g. If measure value =800Lux and the standard value = 750Lux, so the calibration value= 750 – 800= -50 (0xFFCE). If the measure value =850Lux and the standard value = 900Lux, so the calibration value= 900 – 850=50 (0x0032) | 0 | 2 | 0 | 0 | 0 | From | To | Description |
---|
-1000 | 1000 | Available rang is -1000Lux to 1000Lux. |
|
204 | Ultraviolet sensor calibration | Ultraviolet sensor calibration. The calibration value = standard value - measure value. E.g. If measure value =9 and the standard value = 8, so the calibration value= 8 – 9= -1 (0xFE). If the measure value =7 and the standard value = 9, so the calibration value= 9 – 7=2 (0x02). | 0 | 1 | 0 | 0 | 0 | From | To | Description |
---|
-10 | 10 | Available rang is -10 to 10. |
|
252 | Enable/disable all configuration parameters to be locked | Enable/disable all configuration parameters to be locked. | 0 | 1 | 0 | 0 | 0 | From | To | Description |
---|
0 | 0 | Disable | 1 | 1 | Enable. |
|
255 | Reset to factory defaults. | Reset to factory defaults. | 0 | 4 | 0 | 0 | 0 | From | To | Description |
---|
1 | 1 | Reset all configuration parameters to factory defaults. | 1431655765 | 1431655765 | Reset the product to factory defaults. | 10 | 255 | Available rang is 1.0℉ to 25.5℉ |
|