2 | Input 2 switch type | Input 2 switch type | 0 | 1 | 0 | 0 | 1 | From | To | Description |
---|
0 | 0 | mono-stable switch type (push button) | 1 | 1 | bi-stable switch type |
|
43 | Power reporting in Watts by time interval for Q2 | Set value means time interval (0 – 32535) in seconds, when power report is send. | 0 | 2 | 0 | 0 | 300 | From | To | Description |
---|
0 | 0 | Reporting Disabled | 1 | 32535 | = 1 second – 32535 seconds. Reporting enabled, Power report is send with time interval set by entered value. |
|
63 | Output Q1 Switch selection | Set value means the type of the device that is connected to the Q1 output. The device type can be normally open (NO) or normally close (NC). | 0 | 1 | 0 | 0 | 0 | From | To | Description |
---|
0 | 0 | When system is turned off the output is 0V (NC). | 1 | 1 | When system is turned off the output is 230V (NO). |
|
42 | Power reporting in Watts by time interval for Q1 | Set value means time interval (0 – 32535) in seconds, when power report is send. | 0 | 2 | 0 | 0 | 300 | From | To | Description |
---|
0 | 0 | Reporting Disabled | 1 | 32535 | = 1 second – 32535 seconds. Reporting enabled, Power report is send with time interval set by entered value. |
|
120 | Digital temperature sensor reporting | If digital temperature sensor is connected, module reports measured temperature on temperature change defined by this parameter. | 0 | 1 | 0 | 0 | 5 | From | To | Description |
---|
0 | 0 | Reporting disabled | 1 | 127 | 0,1 deg.C - 12.7 deg.C. - step is 0,1 deg.C |
|
40 | Power reporting in Watts on power change for Q1 | Set value means percentage, set value from 0 – 100 = 0% - 100%. | 0 | 1 | 0 | 0 | 10 | From | To | Description |
---|
0 | 0 | Reporting Disabled | 1 | 100 | 1% - 100% Reporting enabled. Power report is send (push) only when actual power in Watts in real time changes for more than set percentage comparing to previous actual power in Watts, step is 1%. NOTE: if power changed is less than 1W, the report is not send (pushed), independent of percentage set. |
|
41 | Power reporting in Watts on power change for Q2 | Set value means percentage, set value from 0 – 100 = 0% - 100% | 0 | 1 | 0 | 0 | 10 | From | To | Description |
---|
0 | 0 | Reporting Disabled | 1 | 100 | 1% - 100% Reporting enabled. Power report is send (push) only when actual power in Watts in real time changes for more than set percentage comparing to previous actual power in Watts, step is 1%. NOTE: if power changed is less than 1W, the report is not send (pushed), independent of percentage set. |
|
64 | Output Q2 Switch selection | Set value means the type of the device that is connected to the Q2 output. The device type can be normally open (NO) or normally close (NC). | 0 | 1 | 0 | 0 | 0 | From | To | Description |
---|
0 | 0 | When system is turned off the output is 0V (NC). | 1 | 1 | When system is turned off the output is 230V (NO). |
|
110 | Temperature sensor offset settings | Set value is added or subtracted to actual measured value by sensor. | 0 | 2 | 0 | 0 | 32536 | From | To | Description |
---|
32536 | 32536 | offset is 0.0 deg.C | 1 | 100 | value from 0.1 deg.C to 10.0 deg.C is added to actual measured temperature. | 1001 | 1100 | value from -0.1 deg.C to -10.0 deg.C is subtracted to actual measured temperature. |
|
1 | Input 1 switch type | Input 1 switch type | 0 | 1 | 0 | 0 | 1 | From | To | Description |
---|
1 | 1 | bi-stable switch type | 0 | 0 | mono-stable switch type (push button) |
|
11 | Automatic turning off output Q1 after set time | When relay Q1 is ON it goes automatically OFF after time defined by this parameter. Timer is reset to zero each time the module receive ON command regardless from where it comes (push button, associated module, controller,..). | 0 | 2 | 0 | 0 | 0 | From | To | Description |
---|
0 | 0 | Auto OFF disabled | 1 | 32535 | 1second (0,01s) – 32535 seconds (325,35s) Auto OFF enabled with define time, step is 1s or 10ms according to parameter nr.15 |
|
10 | Activate / deactivate functions ALL ON/ALL OFF | Activate / deactivate functions ALL ON/ALL OFF Flush 2 relays module responds to commands ALL ON / ALL OFF that may be sent by the main controller or by other controller belonging to the system. | 0 | 2 | 0 | 0 | 255 | From | To | Description |
---|
255 | 255 | ALL ON active, ALL OFF active | 0 | 0 | ALL ON is not active ALL OFF is not active | 1 | 1 | ALL ON is not active ALL OFF active | 2 | 2 | ALL ON active ALL OFF is not active |
|