| Product Recognition | |
|---|
| Certification Number | ZC10-16015002 |
|---|
| Name | 10 Year Smoke Detector and Siren |
|---|
| Short Description | EN 14604 certified 10 Year Smoke Detector with built in Z-Wave controllable siren function |
|---|
| Long Description | This products consists of a standard high-quality photo electric Smoke detector with a pluggable Z-Wave wireless interface module.
The Smoke detector will also work as a stand alone product and is certified by VDS as '10 year Smoke Detector' The
smoke chamber of the detector has a stainless steel reel with antistatic plastic chamber.
A button allows on-device test of smoke chamber, electronics and battery. The device also offers a built-in self test and
an electronic smoke chamber test to avoid the use of test aerosol. A low battery warning will last for 30 days but full
function of the detector is guaranteed during this time.
The Z-Wave module allows to report the smoke and low battery alarm wirelessly to a central controller. The detector can
also be used as a wireless siren for alarm system or other applications. |
|---|
| Brand | Z-Wave.Me |
|---|
| Product Identifier | 009402 |
|---|
| OEM Version | HW: 1 FW: 1.00 |
|---|
| Hardware Platform | ZM5202 |
|---|
| Z-Wave Version | 6.51.06 |
|---|
| Library Type | SLAVE_ENHANCED_232 |
|---|
| Device Type | Notification Sensor |
|---|
| Role Type | ROLE_TYPE_SLAVE_SLEEPING_LISTENING |
|---|
| Manufacturer ID | 0x0115 |
|---|
| Product Type ID | 0x0004 |
|---|
| Product ID | 0x0003 |
|---|
| User Icon | 0x0C01 |
|---|
| Installer Icon | 0x0C01 |
|---|
| Frequency Plans | EU: 869.85MHz, 868.40MHz |
|---|
| Categories | Sensors, Security Add-Ons |
|---|
| Countries / Regions | European Union |
|---|
| Controlled Command Classes | | Identifier | Name | Key | Version |
|---|
| COMMAND_CLASS_BASIC | Basic | 0x20 | 1 |
|
|---|
| Documents | |
|---|
| Association Groups | | Group Number | Maximum Nodes Supported | End Point ID | Description |
|---|
| 1 | 10 | 0 | Z-Wave Plus Lifeline | | 3 | 10 | 0 | Switching Command. All devices in this group will receive a BASIC SET command on Smoke Alarms. Configuration parameter 3 and 4 will define when ON and when OFF is sent. | | 2 | 10 | 0 | Alarm Reports. All devices in this group will receive Alarm notifications (Smoke , Battery Low, Tamper) |
|
|---|
| Configuration Parameters | | Parameter Number | Name | Description | Format | Size | Min Value | Max Value | Default Value | Parameter Values |
|---|
| 4 | Value of Off-Command | This value is sent as BASIC Set to Association Group 3 when an Smoke Alarm is cleared. | 0 | 1 | 0 | 0 | 0 | | | 1 | Siren alarm sequence interval | The additional siren is creating a different acoustic signal differentiate from the smoke alarm. This sound is partly on and partly off. This parameter defines the total length of the interval in seconds. | 0 | 1 | 0 | 0 | 10 | | From | To | Description |
|---|
| 6 | 129 | seconds | | 0 | 0 | |
| | 2 | Siren alarm tone length | The additional siren is creating a different acoustic signal differentiate from the smoke alarm. This sound is partly on and partly off. This parameter defines the total length of the sound versus silence within this interval. Please make sure this value is always smaller (shorter time) than parameter 1 that defines the whole sequence. | 0 | 1 | 0 | 0 | 8 | | From | To | Description |
|---|
| 1 | 99 | seconds | | 0 | 0 | |
| | 3 | Value of On-Command | This value is sent as BASIC Set to Association Group 3 when an Smoke Alarm occurs. | 0 | 1 | 0 | 0 | 99 | |
|
|---|
| Texts | | ID | Description | Value |
|---|
| 1 | Inclusion | To include the device start the inclusion on your controller and then hit the little button on the wireless module for 1 second | | 2 | Exclusion | To exclude the device start the inclusion on your controller and then hit the little button on the wireless module for 1 second | | 5 | Factory Reset | To reset the device keep the button pushed for 10 seconds. After 5 seconds the led starts flashing and after another 5
seconds there is a short beep signaling the successful reset back to factory defaults. Use this procedure only when the network primary controller is missing or otherwise inoperable. |
|
|---|
| Supports NWI | Yes |
|---|
| Supports Explorer Frames | Yes |
|---|
| Is Flirs | Yes |
|---|