| 1 | Watt Meter Report Period | If the setting is configured for 1hour (set value =720), the TZ04 will report its instant power consumption every 1 hour to the node of correspond Group. The maximum interval to report its instant power consumption is 45 hours (5s*32767/3600=45hr). | 0 | 2 | 0 | 0 | 720 | | From | To | Description |
|---|
| 1 | 32767 | 720*5s=3600s=1 hour |
|
| 2 | KWH Meter Report Period | If the setting is configured for 1hour (set value =6), the TZ04 will report its Accumulated Power Consumption (KW/h) every 1 hour to the node of correspond Group. The maximum interval to report its Accumulated Power Consumption (KW/h) is 227.55 days (10min*32767/1440=227.55 days). | 0 | 2 | 0 | 0 | 6 | | From | To | Description |
|---|
| 1 | 32767 | 6*10min= 1 hour |
|
| 3 | Selected Relay | If Controller not using Multi_Channel command class to access the relay of TZ04, you may configure the select value to react the Basic Command Class、Binary Switch Command Class or Meter Command Class V3. | 0 | 1 | 0 | 0 | 3 | | From | To | Description |
|---|
| 1 | 1 | 1:Relay1 | | 2 | 2 | 2:Relay2 | | 3 | 3 | 3:Relay1 & Relay2 |
|
| 4 | Edge and Pulse mode | Manual switch S1 and S2 can set to Edge mode or Pulse mode or Edge-Toggle mode, default value is Edge mode. | 0 | 1 | 0 | 0 | 1 | | From | To | Description |
|---|
| 1 | 1 | 1:Edge mode | | 2 | 2 | 2:Pulse mode | | 3 | 3 | 3:Edge-Toggle mode |
|
| 5 | Threshold of Current for Load Caution | This is a warning when the current of load over the preset threshold value, if the setting value is 750, when the load current of Relay1 or Relay2 over this value, TZ04 will send current meter report to the node of correspond Group, the Range of the setting value is from 10 to 750, and the default value is 750. | 0 | 2 | 0 | 0 | 750 | | From | To | Description |
|---|
| 10 | 750 | 750*0.01A = 7.5A |
|
| 6 | Threshold of KWh for Load Caution | This is a warning when the KWh of load over the preset threshold value, If the setting value is 10000, when the Accumulated Power Consumption of Relay1 or Relay2 over this value, TZ04 will send KWh Meter Report command to the node of correspond Group, minimum value is 1KWh and default value is 10000 kWh. | 0 | 2 | 0 | 0 | 10000 | | From | To | Description |
|---|
| 1 | 10000 | 10000*1KWh = 10000KWh |
|
| 7 | Restore switch state mode | Whenever the AC power return from lost, TZ04 will restore the switch state which could be SWITCH OFF、LAST SWITCH STATE、SWITCH ON. The default setting is LAST SWITCH STATE. | 0 | 1 | 0 | 0 | 1 | | From | To | Description |
|---|
| 0 | 0 | 0 : Switch off | | 1 | 1 | 1 : Last switch state | | 2 | 2 | 2 : Switch on |
|
| 8 | Auto off timer | Whenever TZ04 switches to on, the auto off timer begin to count down. After the timer decrease to zero, it will switch off automatically. However if Auto off timer is set as 0, the auto off function will be disabled. The default setting is 0. | 0 | 2 | 0 | 0 | 0 | | From | To | Description |
|---|
| 0 | 0 | 0 : Disable auto off function | | 1 | 32767 | 1-0x7FFF : 1s ~ 32767s |
|
| 9 | RF off command mode | Whenever a switch off command, BASIC_SET、BINARY_SWITCH_SET、SWITCH_ALL_OFF, is received, it could be interpreted as 4 kinds of commands. 1. Switch Off : It switches to OFF state. The default setting is Switch Off. 2. Ignore : The switch off command will be ignored. 3. Switch Toggle : It switches to the inverse of current state. 4. Switch On : It switches to ON state. | 0 | 1 | 0 | 0 | 0 | | From | To | Description |
|---|
| 0 | 0 | 0 : Switch off | | 1 | 1 | 1 : Ignore | | 2 | 2 | 2 : Switch toggle | | 3 | 3 | 3 : Switch on |
|
| 10 | Existence of Endpoint3 | Multi-Channel Command is a good way to control relay1 and relay2 of TZ04 individually. The endpoint3 of TZ04 is related to both relay1 and relay2. In some condition it becomes redundant in Multi-Channel Command Class. When the Existence of Endpoint3 is set as 2, the endpoint3 will be disabled. The default value is 1. Endpoint1 and Endpoint2 are fixed, only Endpoint3 is dynamic. | 0 | 1 | 0 | 0 | 1 | | From | To | Description |
|---|
| 1 | 1 | 1 : Endpoint3 exist | | 2 | 2 | 2 : No Endpoint3 |
|