| 4 | Range test after double click | Allows to enable activation of Z-Wave range test with double click of a TMP button. | 0 | 1 | 0 | 0 | 0 | | From | To | Description |
|---|
| 1 | 1 | enabled | | 0 | 0 | disabled |
|
| 31 | Reporting tamper alarm cancellation | Reporting cancellation of tamper alarm to the controller and 5th association group. | 0 | 1 | 0 | 0 | 1 | | From | To | Description |
|---|
| 0 | 0 | do not send tamper cancellation report | | 1 | 1 | send tamper cancellation report |
|
| 11 | Commands sent to 2nd association group | Command frames sent to devices added to the 2nd association group. | 0 | 1 | 0 | 0 | 2 | | From | To | Description |
|---|
| 1 | 1 | OFF | | 2 | 2 | ON & OFF | | 0 | 0 | ON |
|
| 2 | Door/Window or alarm status | Parameter defines state of the sensor when the magnet is close. If the alarm sensor is connected, it determines the output type. Parameter inactive in external button mode (parameter 1 set to 1). | 0 | 1 | 0 | 0 | 0 | | From | To | Description |
|---|
| 1 | 1 | door/window opened | | 0 | 0 | door/window closed |
|
| 10 | 2nd association group triggers | Parameter defines events which result in sending on/off commands to devices added to the 2nd association group. These commands are sent alternately to switch the devices on and off. Commands represent the values of BASIC SET command frames. Parameter is inactive in external button mode (parameter 1 set to 1). | 0 | 1 | 0 | 0 | 0 | | From | To | Description |
|---|
| 2 | 2 | switch after closing | | 0 | 0 | switch after opening and closing | | 1 | 1 | switch after opening |
|
| 1 | Operation mode | Parameter defines device operation mode. CAUTION Do not install the magnet if the device is not used as a Door/Window Sensor, as it might lead to the malfunction of the device. | 0 | 1 | 0 | 0 | 0 | | From | To | Description |
|---|
| 0 | 0 | Door/Window Sensor or external alarm sensor | | 1 | 1 | external button |
|
| 50 | Interval of temperature measurements | This parameter defines how often the temperature will be measured. The shorter the time, the more frequently the temperature will be measured, but the battery life will shorten. | 0 | 2 | 0 | 0 | 300 | | From | To | Description |
|---|
| 0 | 0 | temperature measurements disabled | | 5 | 32400 | time in seconds |
|
| 51 | Temperature reports threshold | This parameter defines the change of temperature in comparison with last reported, resulting in temperature report being sent to the main controller. | 0 | 2 | 0 | 0 | 10 | | From | To | Description |
|---|
| 0 | 0 | temperature reports based on threshold disabled | | 1 | 300 | temperature threshold |
|
| 53 | Temperature offset | The value to be added to the actual temperature, measured by the sensor (temperature compensation). | 0 | 4 | 0 | 0 | 0 | | From | To | Description |
|---|
| -1000 | 1000 | -100 – 100 degrees Celsius, in 0,1 degrees steps |
|
| 55 | High temperature alarm threshold | If temperature is higher than set value, overheat notification will be sent and high temperature scene will be triggered (if activated). | 0 | 2 | 0 | 0 | 540 | | From | To | Description |
|---|
| 0 | 1000 | 0 - 100 degrees Celsius, in 0,1 degrees steps |
|
| 71 | Alarm broadcast | Settings for broadcasting ON/OFF commands, sensor alarm and tamper alarm. Value other than 0 means alarms are sent in Broadcast Mode, to all devices only within the range of the device. They are not repeated by the mesh network. NOTE Values of parameter 71 may be combined, e.g. 1+2=3 means ON/OFF commands and sensor alarm are sent in Broadcast Mode. | 0 | 1 | 0 | 0 | 0 | | From | To | Description |
|---|
| 4 | 4 | tamper alarm broadcast active | | 0 | 0 | broadcasts inactive | | 1 | 1 | ON/OFF commands broadcast active | | 2 | 2 | sensor alarm broadcast active |
|
| 52 | Interval of temperature reports | Interval of temperature reports. NOTE Temperature measurement is performed before sending any report (regardless of parameter no. 50). Excessive reporting can affect battery lifetime. Reporting on the basis of temperature change (parameter no. 51) is recommended. | 0 | 2 | 0 | 0 | 0 | | From | To | Description |
|---|
| 0 | 0 | periodic temperature reports disabled | | 5 | 32400 | time in seconds |
|
| 54 | Temperature alarm reports | Temperature alarms reported to the Z-Wave controller. Thresholds are set in parameters 55 and 56. | 0 | 1 | 0 | 0 | 0 | | From | To | Description |
|---|
| 1 | 1 | high temperature alarm | | 2 | 2 | low temperature alarm | | 3 | 3 | high and low temperature alarms enabled | | 0 | 0 | temperature alarms disabled |
|
| 3 | Visual LED indications | This parameter defines events indicated by the visual LED indicator. Disabling events might extend battery life. NOTE Values of parameter 3 may be combined, e.g. 1+2=3 means opening/closing and wake up will be indicated by the visual indicator. | 0 | 1 | 0 | 0 | 6 | | From | To | Description |
|---|
| 1 | 1 | indication of opening/closing status change (input IN) | | 2 | 2 | indication of wake up (1 x click or periodical) | | 4 | 4 | indication of device tampering | | 0 | 0 | no indications |
|