| 252 | Lock/unlock all configuration parameters. | Lock/unlock all configuration parameters. | 0 | 1 | 0 | 0 | 0 | | From | To | Description |
|---|
| 0 | 0 | Unlock. | | 1 | 1 | Lock. |
|
| 255 | Reset the Sensor. | Reset the Sensor. | 0 | 4 | 0 | 0 | 0 | | From | To | Description |
|---|
| 0 | 0 | Reset to default settings. | | 1431655765 | 1431655765 | Reset to default settings and excluded from the network. |
|
| 1 | Which value of the Sensor Binary Report or Basic Set will be sent when the door is Opened/Closed. | To set which value of the Sensor Binary Report or Basic Set will be sent when the door is Opened/Closed. | 0 | 1 | 0 | 0 | 1 | | From | To | Description |
|---|
| 0 | 0 | Sensor Binary Report/Basic Set =0xFF when the door is opened, Sensor Binary Report/Basic Set= 0x00 when the door is closed. | | 1 | 1 | Sensor Binary Report/Basic Set= 0x00 when the door is opened, Sensor Binary Report/Basic Set=0xFF when the door is closed. |
|
| 101 | Enable/disable the function of parameter 111 | Enable/disable the function of parameter 111. Note: this parameter cannot disable the low battery checking of the Sensor itself. | 0 | 1 | 0 | 0 | 1 | | From | To | Description |
|---|
| 0 | 0 | Disable. | | 1 | 1 | Enable. |
|
| 111 | Set the interval time of low battery checking. | Set the interval time of low battery checking. Note: 1, if the value is less than 10, the time unit is second. If the value is more than 10, the time unit is 4 minutes, which means if the value is more than 10 and less than 240, the interval time is 4 minutes. If the value is more than 240 and less than 480, the interval is 8 minutes. 2, if the current battery report falls below the low battery value (configurable parameter 39), it will send battery report=0xFF. | 0 | 4 | 0 | 0 | 86640 | | From | To | Description |
|---|
| 0 | 2147483647 | The range of interval can be set to 0 to 2147483647. |
|
| 121 | To configure which sensor report will be sent when the door is opened/closed. | To configure which sensor report will be sent when the door is opened/closed. | 0 | 1 | 0 | 0 | 1 | | From | To | Description |
|---|
| 3 | 3 | Basic Set CC and Sensor Binary Report CC are selected. | | 1 | 1 | Basic Set CC is selected. | | 2 | 2 | Sensor Binary Report CC is selected. |
|