| 1 | EP 1 Type | End point 1 Type | 0 | 2 | 0 | 0 | 0 | | From | To | Description |
|---|
| 1 | 1 | Blind up | | 2 | 2 | Blind down | | 0 | 0 | On/Off Switch |
|
| 4 | EP 1 Output | End point 1 Output – Relay number | 0 | 2 | 0 | 0 | 1 | | From | To | Description |
|---|
| 1 | 6 | Relay number | | 0 | 0 | Not used |
|
| 5 | EP 2 Type | End point 2 Type | 0 | 2 | 0 | 0 | 0 | | From | To | Description |
|---|
| 0 | 0 | On/Off Switch | | 1 | 1 | Blind up | | 2 | 2 | Blind down |
|
| 8 | EP 2 Output | End point 2 Output – Relay number. | 0 | 2 | 0 | 0 | 2 | | From | To | Description |
|---|
| 1 | 6 | Relay number | | 0 | 0 | Not used |
|
| 25 | EP 7 Type | End point 7 Type | 0 | 2 | 0 | 0 | 0 | | From | To | Description |
|---|
| 0 | 0 | On/Off Switch | | 1 | 1 | Blind up | | 2 | 2 | Blind down |
|
| 23 | EP 6 Blind Duration | End point 6 Default blind duration in seconds. In case of type = Switch: • Blind Duration is 0 | 0 | 2 | 0 | 0 | 0 | | From | To | Description |
|---|
| 3 | 127 | Seconds |
|
| 24 | EP 6 Output | End point 6 Output – Relay number. | 0 | 2 | 0 | 0 | 6 | | From | To | Description |
|---|
| 1 | 6 | Relay number | | 0 | 0 | Not used |
|
| 31 | EP 8 Blind Duration | End point 8 Default blind duration in seconds. In case of type = Switch: • Blind Duration is 0 | 0 | 2 | 0 | 0 | 0 | | From | To | Description |
|---|
| 3 | 127 | Seconds |
|
| 3 | EP 1 Blind Duration | End point 1 Default blind duration in seconds. In case of type = Switch: • Blind Duration is 0 | 0 | 2 | 0 | 0 | 0 | | From | To | Description |
|---|
| 3 | 127 | Seconds |
|
| 7 | EP 2 Blind Duration | End point 2 Default blind duration in seconds. In case of type = Switch: • Blind Duration is 0 | 0 | 2 | 0 | 0 | 0 | | From | To | Description |
|---|
| 3 | 127 | Seconds |
|
| 9 | EP 3 Type | End point 3 Type | 0 | 2 | 0 | 0 | 0 | | From | To | Description |
|---|
| 0 | 0 | On/Off Switch | | 1 | 1 | Blind up | | 2 | 2 | Blind down |
|
| 11 | EP 3 Blind Duration | End point 3 Default blind duration in seconds. In case of type = Switch: • Blind Duration is 0 | 0 | 2 | 0 | 0 | 0 | | From | To | Description |
|---|
| 3 | 127 | Seconds |
|
| 17 | EP 5 Type | End point 5 Type | 0 | 2 | 0 | 0 | 0 | | From | To | Description |
|---|
| 0 | 0 | On/Off Switch | | 1 | 1 | Blind up | | 2 | 2 | Blind down |
|
| 2 | EP 1 Partner Id | End point 1 partner id, Blind contain 2 end points (up/down) In case of type = Blind up/down: • Blind must contain Partner Id which is different than 0 and it must be unique In case of type = Switch: • Partner Id which is 0. | 0 | 2 | 0 | 0 | 0 | | From | To | Description |
|---|
| 1 | 9 | End point Id |
|
| 6 | EP 2 Partner Id | End point 2 partner id, Blind contain 2 end points (up/down) In case of type = Blind up/down: • Blind must contain Partner Id which is different than 0 and it must be unique In case of type = Switch: • Partner Id which is 0. | 0 | 2 | 0 | 0 | 0 | | From | To | Description |
|---|
| 1 | 9 | End point Id |
|
| 10 | EP 3 Partner Id | End point 3 partner id, Blind contain 2 end points (up/down) In case of type = Blind up/down: • Blind must contain Partner Id which is different than 0 and it must be unique In case of type = Switch: • Partner Id which is 0. | 0 | 2 | 0 | 0 | 0 | | From | To | Description |
|---|
| 1 | 9 | End point Id |
|