| Product Recognition | |
|---|
| Certification Number | ZC10-16085199 |
|---|
| Name | Gas Detector |
|---|
| Short Description | Gas Detector |
|---|
| Long Description | Gas Keeper (HT-A20) is the safety product to protect life and property from the secondary accidents (fire, explosion, etc.) with its voice message and warning alarm. |
|---|
| Brand | Gas Keeper |
|---|
| Product Identifier | HT-A20 |
|---|
| OEM Version | HW: 1 FW: 39.18 |
|---|
| Hardware Platform | ZM5101 |
|---|
| Z-Wave Version | 6.51.08 |
|---|
| Library Type | SLAVE_ENHANCED_232 |
|---|
| Device Type | Notification Sensor |
|---|
| Role Type | ROLE_TYPE_SLAVE_ALWAYS_ON |
|---|
| Manufacturer ID | 0x024C |
|---|
| Product Type ID | 0x0100 |
|---|
| Product ID | 0x0101 |
|---|
| User Icon | 0x0C02 |
|---|
| Installer Icon | 0x0C02 |
|---|
| Frequency Plans | KR: 920.90MHz, 921.70MHz, 923.10MHz |
|---|
| Categories | Sensors |
|---|
| Countries / Regions | Republic of Korea |
|---|
| Documents | |
|---|
| Features | | Feature | Values |
|---|
| Color | | | Firmware Updatable | | Value |
|---|
| Updatable by Manufacturer |
|
|
|---|
| Association Groups | | Group Number | Maximum Nodes Supported | End Point ID | Description |
|---|
| 1 | 5 | 0 | Lifeline between Controller and Gas Detector.
Supported command classes are notification report, and device reset locally notification.(Lifeline) |
|
|---|
| Texts | | ID | Description | Value |
|---|
| 4 | Device Wake-Up | Non battery | | 1 | Inclusion | Press On/OFF button for 5 seconds till hearing beep once.
When inclusion completes, you will hear ‘beep’ sound with voice message alert. When inclusion completes, Connection LED will be on. | | 2 | Exclusion | Press On/OFF button for 5 seconds till hearing beep once.
When exclusion completes, you will hear ‘beep’ sound with voice message alert. When exclusion completes, Connection LED will be off. (The same as the inclusion method) | | 5 | Factory Reset | Press On/OFF button for 10 seconds till hearing beep once.
When reset completes, you will hear ‘beep’ sound with voice message alert.
(Reset function, the primary controller will be used only when does not exist or inoperative.) | | 6 | Additional Special Features | Detect gas leak.
Notify gas leak via voice message and warning alarm.
* When the gas ventilation completes after gas leak alarm, it will operate normally. (No need to reset) |
|
|---|
| Supports NWI | Yes |
|---|
| Supports Explorer Frames | Yes |
|---|