81 | To set which notification would be sent to the associated nodes in association group 3 | To set which notification would be sent to the associated nodes in association Group 3 when using the external switch 1 to switch the loads. | 0 | 1 | 0 | 0 | 1 | From | To | Description |
---|
0 | 0 | Send Nothing | 1 | 1 | Send Basic Set CC |
|
82 | To set which notification would be sent to the associated nodes in association group 4 | To set which notification would be sent to the associated nodes in association Group 4 when using the external switch 2 to switch the loads. | 0 | 1 | 0 | 0 | 1 | From | To | Description |
---|
0 | 0 | Send Nothing | 1 | 1 | Send Basic Set CC |
|
83 | Configure the state of LED when it is in 3 modes | Configure the state of LED when it is in 3 modes (Energy mode, Momentary indicate mode, Night light mode) | 0 | 1 | 0 | 0 | 0 | From | To | Description |
---|
2 | 2 | Night light mode. The LED will remain ON state. | 0 | 0 | Energy mode. The LED will follow the status (on/off). | 1 | 1 | Momentary indicate mode. When the state of Switch’s load changed, the LED will follow the status (on/off) of its load, but the LED will turn off after 5 seconds if there is no any switch action. |
|
84 | Set the ON/OFF time of the LED when it is in Night light mode. | Set the ON/OFF time of the LED when it is in Night light mode. | 0 | 1 | 0 | 0 | 301991936 | From | To | Description |
---|
0 | 60 | The minute time of OFF | 256 | 316 | The hour time of OFF | 65536 | 65596 | The minute time of ON | 16777216 | 16777276 | The hour time of ON |
|
86 | Set appointment 1 | Set the ON time of output load. | 0 | 4 | 0 | 0 | 8327680 | From | To | Description |
---|
65536 | 65543 | The day value (Mon to Sun) | 16777216 | 16777216 | Enable the setting. | 256 | 316 | The hour value of ON time | 16777215 | 16777215 | Disable the setting. | 0 | 60 | The minute value of ON time |
|
87 | Set appointment 2 | Set the OFF time of output load. | 0 | 4 | 0 | 0 | 8327680 | From | To | Description |
---|
256 | 316 | The hour value of ON time | 65536 | 65543 | The day value (Mon to Sun) | 16777215 | 16777215 | Disable the setting. | 0 | 60 | The minute value of ON time | 16777216 | 16777216 | Enable the setting. |
|
90 | Enables/disables parameter 91 and 92 below: | Enables/disables the function of parameter 91 and 92. | 0 | 1 | 0 | 0 | 0 | From | To | Description |
---|
0 | 0 | Disable | 1 | 1 | Enable |
|
91 | Set the threshold value of wattage. | Threshold change in wattage (in terms of wattage) to induce an automatic report. | 0 | 2 | 0 | 0 | 25 | From | To | Description |
---|
0 | 60000 | The thershold value range is 0 to 60000 |
|
92 | Set the threshold value of wattage. | Threshold change in wattage (in terms of percentage) to induce an automatic report. | 0 | 1 | 0 | 0 | 5 | From | To | Description |
---|
0 | 100 | The thershold value range is 0 to 100 |
|
100 | Set parameter 101-103 to default value. | Set parameter 101-103 to default value. | 0 | 1 | 0 | 0 | 0 | From | To | Description |
---|
0 | 0 | Reset the parameter 101-103 |
|
101 | To set which reports need to be sent in Report group 1. | To set which reports need to be sent in Report group 1. | 0 | 4 | 0 | 0 | 0 | From | To | Description |
---|
4 | 4 | Send Meter Report of voltage (V) | 2 | 2 | Send Meter Report of wattage (W) | 8 | 8 | Send Meter Report of current (A) | 1 | 1 | Send Meter Report of energy (kWh) |
|
102 | To set which reports need to be sent in Report group 2. | To set which reports need to be sent in Report group 2. | 0 | 1 | 0 | 0 | 0 | From | To | Description |
---|
1 | 1 | Send Meter Report of energy (kWh) | 2 | 2 | Send Meter Report of wattage (W) | 4 | 4 | Send Meter Report of voltage (V) | 8 | 8 | Send Meter Report of current (A) |
|
103 | To set which reports need to be sent in Report group 3. | To set which reports need to be sent in Report group 3. | 0 | 1 | 0 | 0 | 0 | From | To | Description |
---|
1 | 1 | Send Meter Report of voltage (V) | 2 | 2 | Send Meter Report of current (A) | 4 | 4 | Send Meter Report of wattage (W) | 8 | 8 | Send Meter Report of energy (kWh) |
|
110 | Set parameter 111-113 to default value. | Set parameter 111-113 to default value. | 0 | 1 | 0 | 0 | 0 | From | To | Description |
---|
0 | 0 | Reset the parameter 111-113 |
|
111 | Set the interval of automatic report for Report group 1. | Set the interval of automatic report for Report group 1. | 0 | 4 | 0 | 0 | 10 | From | To | Description |
---|
1 | 2147483647 | The range of interval time is 1 to 2147483647. |
|
112 | Set the interval of automatic report for Report group 2. | Set the interval of automatic report for Report group 2. | 0 | 4 | 0 | 0 | 600 | From | To | Description |
---|
1 | 2147483647 | The range of interval time is 1 to 2147483647. |
|
113 | Set the interval of automatic report for Report group 2. | Set the interval of automatic report for Report group 3. | 0 | 4 | 0 | 0 | 600 | From | To | Description |
---|
1 | 2147483647 | The range of interval time is 1 to 2147483647. |
|
120 | Configure the external switch mode for S1. | Configure the external switch mode for S1. | 0 | 1 | 0 | 0 | 0 | From | To | Description |
---|
0 | 0 | Enter automatic identification mode | 1 | 1 | 2-state switch mode | 2 | 2 | 3 way switch mode | 3 | 3 | Momentary push button mode |
|
121 | Configure the external switch mode for S2. | Configure the external switch mode for S2. | 0 | 1 | 0 | 0 | 0 | From | To | Description |
---|
0 | 0 | Enter automatic identification mode | 1 | 1 | 2-state switch mode | 2 | 2 | 3 way switch mode | 3 | 3 | Momentary push button mode |
|
122 | Set the control destination for external switch | Set the control destination for external switch | 0 | 1 | 0 | 0 | 3 | From | To | Description |
---|
1 | 1 | control the output loads of itself. | 2 | 2 | control the other nodes | 3 | 3 | control the output loads of itself and other nodes. |
|
252 | Lock/unlock configuration parameters | Lock/unlock configuration parameters. | 0 | 1 | 0 | 0 | 0 | From | To | Description |
---|
0 | 0 | Unlock | 1 | 1 | Lock |
|
255 | Reset the Nano Switch | Reset the Nano Switch to factory default. | 0 | 4 | 0 | 0 | 0 | From | To | Description |
---|
0 | 0 | Reset all configuration parameters to factory default setting | 1431655765 | 1431655765 | Reset to factory default setting and removed from the z-wave network |
|
3 | Current Overload Protection. | Output Load will be turned off automatically after 30 seconds and if the current overrun 15.5A. | 0 | 1 | 0 | 0 | 1 | From | To | Description |
---|
0 | 0 | Disable | 1 | 1 | Enable |
|
4 | Overheat protection. | Output Load will be turned off automatically after 30 seconds and if the temperature of product inside exceeds 100 ℃. | 0 | 1 | 0 | 0 | 0 | From | To | Description |
---|
0 | 0 | Disable | 1 | 1 | Enable |
|
80 | To set which notification would be sent to the associated devices (Group 1) | To set which notification would be sent to the associated devices (Group 1) when the state of Nano Dimmer’s load is changed. | 0 | 1 | 0 | 0 | 3 | From | To | Description |
---|
0 | 0 | Send Nothing | 1 | 1 | Send Hail CC | 2 | 2 | Send Basic Report CC | 3 | 3 | Send Hail CC when using the manual switch to change the load state. |
|