55 | Cool Timer (hours) | Sets Cool Timer (hours). 0 to 4000. | 0 | 2 | 0 | 0 | 0 | From | To | Description |
---|
0 | 4000 | Hours |
|
11 | H Delta Stage 1 ON | Sets the delta from setpoint that stage 1 heating starts | 0 | 1 | 0 | 0 | 1 | From | To | Description |
---|
1 | 6 | Degrees |
|
24 | Display Lock | Sets locking and unlocking of control of the display screen. | 0 | 1 | 0 | 0 | 0 | From | To | Description |
---|
0 | 0 | Unlocked | 1 | 1 | Locked |
|
3 | Change Over Type | Sets change over type. Change over with cool or change over with heat. | 0 | 1 | 0 | 0 | 0 | From | To | Description |
---|
1 | 1 | CO w/Heat | 0 | 0 | CO w/Cool |
|
43 | Remote Sensor 1 Node Number | Sets remote sensor 1 node number. 0=disabled. | 0 | 1 | 0 | 0 | 0 | From | To | Description |
---|
0 | 252 | node number |
|
4 | 2nd Stage Heat Enable | Enables or disables the second stage heat operation. | 0 | 1 | 0 | 0 | 0 | From | To | Description |
---|
1 | 1 | Enabled | 0 | 0 | Disabled |
|
9 | MRT | Sets the Minimum Run Time (MRT) delay before a heating/cooling cycle can turn off. Sets heating/cooling cycle time. Prevents rapid on/off cycling. | 0 | 1 | 0 | 0 | 3 | From | To | Description |
---|
3 | 9 | Minutes |
|
6 | 2nd Stage Cool Enable | Enables or disables the second stage cool operation. | 0 | 1 | 0 | 0 | 0 | From | To | Description |
---|
1 | 1 | Enabled | 0 | 0 | Disabled |
|
1 | System Type | Sets the system type. Standard or Heat Pump | 0 | 1 | 0 | 0 | 0 | From | To | Description |
---|
1 | 1 | Heat Pump | 0 | 0 | Standard |
|
46 | Remote Sensor 1 Temperature | Displays remote sensor 1 Temperature. | 0 | 1 | 0 | 0 | 0 | |
49 | R1 Sensor Temp Off set | Sets R1 Sensor Temp Offset. -7 to 7 degrees | 0 | 1 | 0 | 0 | 0 | From | To | Description |
---|
-7 | 7 | Degrees |
|
52 | Filter Timer (hours) | Sets Filter Timer (hours). 0 to 4000 | 0 | 2 | 0 | 0 | 0 | From | To | Description |
---|
0 | 4000 | Hours |
|
48 | Internal Sensor Temp Offset | Sets Internal Sensor Temp Offset. -7 to 7 | 0 | 1 | 0 | 0 | 0 | From | To | Description |
---|
-7 | 7 | Degrees |
|
17 | C Delta Stage 1 ON | Sets the delta from setpoint that stage 1 cooling starts. | 0 | 1 | 0 | 0 | 1 | From | To | Description |
---|
1 | 6 | Degrees |
|
2 | Fan Type | Sets the fan type. Electric (Fan w/Heat) or Gas (no Fan w/Heat) | 0 | 1 | 0 | 0 | 0 | From | To | Description |
---|
1 | 1 | Electric (Fan w/Heat | 0 | 0 | Gas (no fan w/Heat |
|
5 | Aux Heat Enable | Enables or disables aux heat operation. | 0 | 1 | 0 | 0 | 1 | From | To | Description |
---|
0 | 0 | Disabled | 1 | 1 | Enabled |
|
7 | C/F Type | Enables changing from Centigrade to Fahrenheit or vice versa. | 0 | 1 | 0 | 0 | 1 | From | To | Description |
---|
1 | 1 | Fahrenheit | 0 | 0 | Centigrade |
|
8 | MOT | Sets the Minimum Off Time (MOT) delay before another heating/cooling cycle can begin. Provides compressor short cycle protection. “Wait” is displayed on screen when active. | 0 | 1 | 0 | 0 | 5 | From | To | Description |
---|
5 | 9 | Minutes |
|
40 | Setback Mode | Enables setback or Un-Occupied mode. Temperature setback reduces how often the heating or cooling system operates by allowing the temperature in a home to drift to a lower (heating mode) or higher (cooling mode) temperature. | 0 | 1 | 0 | 0 | 0 | From | To | Description |
---|
0 | 0 | No Setback | 2 | 2 | Un-Occupied Mode |
|
53 | Filter Timer Max (hrs) | Sets Filter Timer Max (hrs). 0 to 4000. | 0 | 2 | 0 | 0 | 300 | From | To | Description |
---|
0 | 4000 | Hours |
|
54 | Heat Timer (hours) | Sets Heat Timer (hours). 0 to 4000. | 0 | 2 | 0 | 0 | 0 | From | To | Description |
---|
0 | 4000 | Hours |
|
61 | Fan Purge Heat | Sets Fan Purge Heat. Sets the system blower delay off time after a heat call ends (fan purge). 0 to 90 Seconds. | 0 | 1 | 0 | 0 | 0 | From | To | Description |
---|
0 | 90 | Seconds |
|
62 | Fan Purge Cool | Sets Fan Purge Cool. Sets the system blower delay off time after a cool call ends (fan purge). 0 to 90 Seconds | 0 | 1 | 0 | 0 | 0 | From | To | Description |
---|
0 | 90 | Seconds |
|
186 | 0xBA | Temperature Delta Autosend Threshold (how many degree change from last autosend). 1 to 5 degrees. | 0 | 1 | 0 | 0 | 2 | From | To | Description |
---|
1 | 5 | Degrees |
|
187 | 0xBB | Periodic Temperature Send Interval (min). 0=Disabled. 1-120 minutes. | 0 | 1 | 0 | 0 | 0 | From | To | Description |
---|
1 | 120 | Minutes |
|