There are over 4392 interoperable Z-Wave products throughout the world, and over 94 million Z-Wave products have been sold since our beginnings in 2001. All of them work together regardless of brand, because they're all based on the common Z - Wavestandard.Browse our Product Finder to see what Z -Wave can do for you.

Z-Wave Configuration Capabilities

Model: CT32 (CT32 RTZW-02)

Z-Wave Certification Number: ZC10-14060001


Parameter Number

Parameter Size

Parameter Name

Parameter Values

1 1 Temperature Reporting Threshold 0 to 4
(Default)
0 = Disabled: 1 = 0.5ºF: 2 = 1.0ºF: 3 = 1.5ºF: 4 = 2.0ºF

Parameter Number

Parameter Size

Parameter Name

Parameter Values

10 2 Temperature Reporting Filter 0 to 31868
(Default)
Byte 1: 0 -124ºF (lower bound), Byte 2: 0-124ºF (upper bound)

Parameter Number

Parameter Size

Parameter Name

Parameter Values

11 1 Simple UI Mode 0 to 1
(Default)
0 = Normal Mode, 1 = Simple Mode

Parameter Number

Parameter Size

Parameter Name

Parameter Values

12 1 Multicast 0 to 1
(Default)
0 = Disabled, 1 = Enabled
  0 to 1
(Default)
0=disabled ,1=enabled
  0 to 65535
(Default)
0=disabled, 1=enabled.
  0 to 1
(Default)
0=disabled, 1=enabled.
  0 to 2
(Default)
0=nothing, 1=hail CC, 2=basic CC report.
  0 to 1
(Default)
0=disabled, 1=enabled.
  0 to 60000
(Default)
The threshold can be set from 0 to 60000 watt.
  0 to 100
(Default)
The threshold can be set from 0 to 100 percent.
  0 to 15
(Default)
When value==1, which means the Voltage report is configured to be sent in Report Group 1. When value==2, which means the Current report is configured to be sent in Report Group 1. When value==4, which means the Wattage report is configured to be sent in Report Group 1. When value==8, which means the KWH report is configured to be sent in Report Group 1. When value==15, which means the Voltage , Current , Wattage and KWH report are all configured to be sent in Report Group 1. The other values will be reserved.
  0 to 15
(Default)
When value==1, which means the Voltage report is configured to be sent in Report Group 2. When value==2, which means the Current report is configured to be sent in Report Group 2. When value==4, which means the Wattage report is configured to be sent in Report Group 2. When value==8, which means the KWH report is configured to be sent in Report Group 2. When value==15, which means the Voltage , Current , Wattage and KWH report are all configured to be sent in Report Group 2. The other values will be reserved.
  0 to 15
(Default)
When value==1, which means the Voltage report is configured to be sent in Report Group 3. When value==2, which means the Current report is configured to be sent in Report Group 3. When value==4, which means the Wattage report is configured to be sent in Report Group 3. When value==8, which means the KWH report is configured to be sent in Report Group 2. When value==15, which means the Voltage , Current , Wattage and KWH report are all configured to be sent in Report Group 3. The other values will be reserved.
  0 to 268435456
(Default)
You have a wide range to set the interval time that can be set from 0 to 268435456 seconds.
  0 to 268435456
(Default)
You have a wide range to set the interval time that can be set from 0 to 268435456 seconds.
  0 to 268435456
(Default)
You have a wide range to set the interval time that can be set from 0 to 268435456 seconds.
  0 to 255
(Default)
There are 255 different partners can be configured.
  0 to 1
(Default)
When value==0, all configuration parameters are configurable. When value==1, all configuration parameters are not configurable.(Locked)

Parameter Number

Parameter Size

Parameter Name

Parameter Values

2 4 HVAC Settings 1 to 2147483647 Byte 1: normal (1) or heat pump (2). Byte 2, Bits 7-4: Gas (1) or Electric (2). Byte 2, Bits 3-0: # of Auxiliary Stages. Byte 3: # of Heat Pump Stages. Byte 4: # of Cool Stages.

Parameter Number

Parameter Size

Parameter Name

Parameter Values

3 1 Utility Lock 0 to 255
(Default)
0 = Disabled, 1 - 255 = Enabled

Parameter Number

Parameter Size

Parameter Name

Parameter Values

4 1 C-Wire/Battery 1 to 2 1=C-Wire, 2=Battery

Parameter Number

Parameter Size

Parameter Name

Parameter Values

5 1 Humidity Reporting Threshold 0 to 3
(Default)
0 = Disabled, 1 = 3% RH, 2 = 5% RH, 3 = 10% RH

Parameter Number

Parameter Size

Parameter Name

Parameter Values

6 1 Auxiliary/Emergency Mode 0 to 1
(Default)
0 = Disabled, 1 = Enabled

Parameter Number

Parameter Size

Parameter Name

Parameter Values

7 1 Thermostat Swing Temperature 1 to 8
(Default)
1 = 0.5ºF, 2 = 1.0ºF, 3 = 1.5ºF, 4 = 2.0ºF, 5 = 2.5ºF, 6 = 3.0ºF, 7 = 3.5ºF, 8 = 4.0ºF

Parameter Number

Parameter Size

Parameter Name

Parameter Values

8 2 Thermostat Differential Temperature 4 to 3084
(Default)
Byte 1: 4 - 12 (heat diff temp), Byte 2: 4 - 12 (cool diff temp)

Parameter Number

Parameter Size

Parameter Name

Parameter Values

9 1 Thermostat Recovery Mode 1 to 2
(Default)
1 = Fast, 2 = Economy