There are over 4392 interoperable
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
1 | 1 | Temperature Reporting Threshold | 0 to 4 (Default) |
0 = Disabled: 1 = 0.5ºF: 2 = 1.0ºF: 3 = 1.5ºF: 4 = 2.0ºF | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
10 | 2 | Temperature Reporting Filter | 0 to 31868 (Default) |
Byte 1: 0 -124ºF (lower bound), Byte 2: 0-124ºF (upper bound) | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
11 | 1 | Simple UI Mode | 0 to 1 (Default) |
0 = Normal Mode, 1 = Simple Mode | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
12 | 1 | Multicast | 0 to 1 (Default) |
0 = Disabled, 1 = Enabled | |
0 to 1 (Default) |
0=disabled ,1=enabled | ||||
0 to 65535 (Default) |
0=disabled, 1=enabled. | ||||
0 to 1 (Default) |
0=disabled, 1=enabled. | ||||
0 to 2 (Default) |
0=nothing, 1=hail CC, 2=basic CC report. | ||||
0 to 1 (Default) |
0=disabled, 1=enabled. | ||||
0 to 60000 (Default) |
The threshold can be set from 0 to 60000 watt. | ||||
0 to 100 (Default) |
The threshold can be set from 0 to 100 percent. | ||||
0 to 15 (Default) |
When value==1, which means the Voltage report is configured to be sent in Report Group 1. When value==2, which means the Current report is configured to be sent in Report Group 1. When value==4, which means the Wattage report is configured to be sent in Report Group 1. When value==8, which means the KWH report is configured to be sent in Report Group 1. When value==15, which means the Voltage , Current , Wattage and KWH report are all configured to be sent in Report Group 1. The other values will be reserved. | ||||
0 to 15 (Default) |
When value==1, which means the Voltage report is configured to be sent in Report Group 2. When value==2, which means the Current report is configured to be sent in Report Group 2. When value==4, which means the Wattage report is configured to be sent in Report Group 2. When value==8, which means the KWH report is configured to be sent in Report Group 2. When value==15, which means the Voltage , Current , Wattage and KWH report are all configured to be sent in Report Group 2. The other values will be reserved. | ||||
0 to 15 (Default) |
When value==1, which means the Voltage report is configured to be sent in Report Group 3. When value==2, which means the Current report is configured to be sent in Report Group 3. When value==4, which means the Wattage report is configured to be sent in Report Group 3. When value==8, which means the KWH report is configured to be sent in Report Group 2. When value==15, which means the Voltage , Current , Wattage and KWH report are all configured to be sent in Report Group 3. The other values will be reserved. | ||||
0 to 268435456 (Default) |
You have a wide range to set the interval time that can be set from 0 to 268435456 seconds. | ||||
0 to 268435456 (Default) |
You have a wide range to set the interval time that can be set from 0 to 268435456 seconds. | ||||
0 to 268435456 (Default) |
You have a wide range to set the interval time that can be set from 0 to 268435456 seconds. | ||||
0 to 255 (Default) |
There are 255 different partners can be configured. | ||||
0 to 1 (Default) |
When value==0, all configuration parameters are configurable. When value==1, all configuration parameters are not configurable.(Locked) | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
2 | 4 | HVAC Settings | 1 to 2147483647 | Byte 1: normal (1) or heat pump (2). Byte 2, Bits 7-4: Gas (1) or Electric (2). Byte 2, Bits 3-0: # of Auxiliary Stages. Byte 3: # of Heat Pump Stages. Byte 4: # of Cool Stages. | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
3 | 1 | Utility Lock | 0 to 255 (Default) |
0 = Disabled, 1 - 255 = Enabled | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
4 | 1 | C-Wire/Battery | 1 to 2 | 1=C-Wire, 2=Battery | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
5 | 1 | Humidity Reporting Threshold | 0 to 3 (Default) |
0 = Disabled, 1 = 3% RH, 2 = 5% RH, 3 = 10% RH | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
6 | 1 | Auxiliary/Emergency Mode | 0 to 1 (Default) |
0 = Disabled, 1 = Enabled | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
7 | 1 | Thermostat Swing Temperature | 1 to 8 (Default) |
1 = 0.5ºF, 2 = 1.0ºF, 3 = 1.5ºF, 4 = 2.0ºF, 5 = 2.5ºF, 6 = 3.0ºF, 7 = 3.5ºF, 8 = 4.0ºF | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
8 | 2 | Thermostat Differential Temperature | 4 to 3084 (Default) |
Byte 1: 4 - 12 (heat diff temp), Byte 2: 4 - 12 (cool diff temp) | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
9 | 1 | Thermostat Recovery Mode | 1 to 2 (Default) |
1 = Fast, 2 = Economy | |