Z-Wave Products

TThere are thousands of interoperable Z-Wave products throughout the world, and over 94 million Z-Wave products have been sold since our beginnings in 2001. All of them work together regardless of brand, because they're all based on the common Z - Wavestandard.Browse our Product Finder to see what Z -Wave can do for you.

Z-Wave Configuration Capabilities

Model: Smart Switch Gen5 (ZW075-A02)

Z-Wave Certification Number: ZC10-14060003


Parameter Number

Parameter Size

Parameter Name

Parameter Values

101 4 To set which report need to be sent. 8 Report Accumulated kWh
  2 Report Instantaneous Current (Amperes)
  4
(Default)
Report Instantaneous Watts
  1 Report Instantaneous Voltage

Parameter Number

Parameter Size

Parameter Name

Parameter Values

102 4 To set which report need to be sent. 1 Report Instantaneous Voltage
  4 Report Instantaneous Watts
  8
(Default)
Report Accumulated kWh
  2 Report Instantaneous Current (Amperes)

Parameter Number

Parameter Size

Parameter Name

Parameter Values

103 4 To set which report need to be sent. 1 Report Instantaneous Voltage
  2 Report Instantaneous Current (Amperes)
  4 Report Instantaneous Watts
  8 Report Accumulated kWh

Parameter Number

Parameter Size

Parameter Name

Parameter Values

111 4 Set the interval time of sending report. 0 to 268435456
(Default)
Interval Seconds

Parameter Number

Parameter Size

Parameter Name

Parameter Values

112 4 Set the interval time of sending report. 0 to 268435456
(Default)
Interval Seconds

Parameter Number

Parameter Size

Parameter Name

Parameter Values

113 4 Set the interval time of sending report. 0 to 268435456
(Default)
Interval Seconds

Parameter Number

Parameter Size

Parameter Name

Parameter Values

2 2 Make Smart Switch blink 0 to 255 Specify the time that Smart Switch should blink, in seconds.
  256 to 32767
(Default)
Specifies the cycle of on/off, the unit of it is 0.1 second.

Parameter Number

Parameter Size

Parameter Name

Parameter Values

200 1 Partner ID 0
(Default)
Aeon Labs Standard Product
  1 to 255 Partner ID of Partner Product

Parameter Number

Parameter Size

Parameter Name

Parameter Values

252 1 Enable/Disable Lock Configuration 0
(Default)
All configuration parameters are configurable.
  1 All configuration parameters are not configurable (Locked).

Parameter Number

Parameter Size

Parameter Name

Parameter Values

254 2 Device Tag 0 to 32767
(Default)
Device Tag

Parameter Number

Parameter Size

Parameter Name

Parameter Values

255 4 Reset to default factory setting 1431655765 Reset the product to default factory setting and be excluded from the Z-wave network.
  1 Resets all configuration parameters to default setting.

Parameter Number

Parameter Size

Parameter Name

Parameter Values

3 1 Current Overload Protection 0
(Default)
Overload Protection Disabled
  1 Overload Protection is Enabled

Parameter Number

Parameter Size

Parameter Name

Parameter Values

80 1 Enable/Disable to send notifications to associated devices to associated devices. 0
(Default)
Send Nothing (Disabled)
  1 Send HAIL Command
  2 Send BASIC Report Command

Parameter Number

Parameter Size

Parameter Name

Parameter Values

90 1 Enable/Disable the function of parameter 91 and 92. 0 Configuration Parameters 91 and 92 are Disabled
  1
(Default)
Configuration Parameters 91 and 92 are Enabled

Parameter Number

Parameter Size

Parameter Name

Parameter Values

91 2 Induce an automatic report 0 to 32767
(Default)
The threshold can be set from 0 to 32767 watt.

Parameter Number

Parameter Size

Parameter Name

Parameter Values

92 1 Induce an automatic report 0 to 100
(Default)
The threshold can be set from 0 to 100 percent.