TThere are thousands of interoperable
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
1 | 2 | Watt Meter Report Period | 1 to 32767 (Default) |
720*5s=3600s=1 hour | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
2 | 2 | KWH Meter Report Period: | 1 to 32767 (Default) |
6*10min=1 hour | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
3 | 2 | Threshold of current for Load Caution | 10 to 1300 (Default) |
1300*0.01A = 13A | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
4 | 2 | Threshold of KWh for Load Caution | 1 to 10000 (Default) |
1KWh ~ 10000KWh | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
5 | 1 | Restore switch state mode | 0 to 2 (Default) |
0 : Switch off 1 : Last switch state 2 : Switch on | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
6 | 1 | Mode of switch off function | 0 to 1 (Default) |
0 : Disable 1 : Enable | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
7 | 1 | LED indication mode | 1 to 3 (Default) |
1 : Show switch state 2 : Show night mode 3 : One flash mode | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
8 | 1 | Auto off timer | 0 to 32767 (Default) |
0 : Disable auto off function 1-0x7FFF : 1s ~ 32767s | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
9 | 1 | RF off command mode | 0 to 3 (Default) |
0 : Switch off 1 : Ignore 2 : Switch toggle 3 : Switch on | |