TThere are thousands of interoperable
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
101 | 4 | To set which report need to be sent. | 4 (Default) |
Report Instantaneous Watts | |
1 | Report Instantaneous Voltage | ||||
8 | Report Accumulated kWh | ||||
2 | Report Instantaneous Current (Amperes) | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
102 | 4 | To set which report need to be sent. | 2 | Report Instantaneous Current (Amperes) | |
1 | Report Instantaneous Voltage | ||||
4 | Report Instantaneous Watts | ||||
8 (Default) |
Report Accumulated kWh | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
103 | 4 | To set which report need to be sent. | 8 | Report Accumulated kWh | |
1 | Report Instantaneous Voltage | ||||
2 | Report Instantaneous Current (Amperes) | ||||
4 | Report Instantaneous Watts | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
111 | 4 | Set the interval time of sending report. | 0 to 268435456 (Default) |
Interval Seconds | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
112 | 4 | Set the interval time of sending report. | 0 to 268435456 (Default) |
Interval Seconds | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
113 | 4 | Set the interval time of sending report. | 0 to 268435456 (Default) |
Interval Seconds | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
20 | 1 | The load status after power on | 2 | The load state will always off stare after re-power on. | |
0 (Default) |
The load state will back to the last state after power on. | ||||
1 | The load state will always on after re-power on. | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
200 | 1 | Partner ID | 0 (Default) |
Aeon Labs Standard Product | |
1 to 255 | Partner ID of Partner Product | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
252 | 1 | Enable/Disable Lock Configuration | 0 (Default) |
All configuration parameters are configurable. | |
1 | All configuration parameters are not configurable (Locked). | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
255 | 4 | Reset to default factory setting | 1431655765 | Reset the product to default factory setting and be excluded from the Z-wave network. | |
1 | Resets all configuration parameters to default setting. | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
3 | 1 | Current Overload Protection | 0 (Default) |
Overload Protection Disabled | |
1 | Overload Protection is Enabled | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
80 | 1 | Enable/Disable to send notifications to associated devices to associated devices. | 2 | Send BASIC Report Command | |
0 (Default) |
Send Nothing (Disabled) | ||||
1 | Send HAIL Command | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
90 | 1 | Enable/Disable the function of parameter 91 and 92. | 0 | Configuration Parameters 91 and 92 are Disabled | |
1 (Default) |
Configuration Parameters 91 and 92 are Enabled | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
91 | 2 | Induce an automatic report | 0 to 32767 (Default) |
The threshold can be set from 0 to 32767 watt. | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
92 | 1 | Induce an automatic report | 0 to 100 (Default) |
The threshold can be set from 0 to 100 percent. | |