There are over 4347 interoperable
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
1 | 2 | Watt Meter Report Period | 1 to 32767 (Default) |
Enable automatic interval reporting with an interval of 5 * the value. | |
0 | Disable automatic interval meter reporting of Watts | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
2 | 2 | KWH Meter Report Period: | 1 to 32767 (Default) |
6*10 min=1 hour | |
0 | Disable automatic interval meter kWh reporting. | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
3 | 2 | Threshold of current for Load Caution | 10 to 1300 (Default) |
1300*0.01A = 13A | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
4 | 2 | Threshold of KWh for Load Caution | 1 to 10000 (Default) |
Enable automatic warning when the accumulated kWh power consumption exceeds the setting value from 1KWh ~ 10000KWh. | |
0 | Disable kWh Load Caution Reporting | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
5 | 1 | Restore switch state mode | 0 | Upon the return of AC power, the switch will remain Off. | |
1 (Default) |
Upon the return of AC power, the switch will return to the state it was in when the power was turned off. | ||||
2 | Upon the return of AC power, the switch will turn On. | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
6 | 1 | Mode of switch off function | 0 | SWITCH OFF commands received are ignored. | |
1 (Default) |
SWITCH OFF commands received are honored. | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
7 | 1 | LED indication mode | 1 (Default) |
The LED follows the state of the switch. | |
2 | Night Mode - When the switch is On, the LED is Off, and when the switch is Off, the LED is On. | ||||
3 | Flash Mode - When the state of the switch changes, the LED will be on for one second and then will turn off. | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
8 | 1 | Auto off timer | 1 to 32767 | 1s ~ 32767s for automatically turning off | |
0 (Default) |
Disable the auto off function | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
9 | 1 | RF off command mode | 0 (Default) |
When SWITCH ALL OFF is received, the MT02646 turns Off. | |
1 | When SWITCH ALL OFF is received, the MT02646 ignores the command and does nothing. | ||||
2 | When SWITCH ALL OFF is received, the MT02646 will turn On if it is Off, and will turn Off if it is On. | ||||
3 | When SWITCH ALL OFF is received, the MT02646 turns On. | ||||