There are over 4297 interoperable Z-Wave products throughout the world, and over 94 million Z-Wave products have been sold since our beginnings in 2001. All of them work together regardless of brand, because they're all based on the common Z - Wavestandard.Browse our Product Finder to see what Z -Wave can do for you.

Z-Wave Configuration Capabilities

Model: Door/Window Contact (MT02648)

Z-Wave Certification Number: ZC10-14090007


Parameter Number

Parameter Size

Parameter Name

Parameter Values

10 1 Auto Report Battery Time 1 to 127
(Default)
Auto Report Battery Time
  0 Turn Off Automatic Interval Battery Reporting

Parameter Number

Parameter Size

Parameter Name

Parameter Values

11 1 Auto Report Door/Window State Time 1 to 127
(Default)
Auto Report Door/Window State Time
  0 Disable automatic interval reporting of the Door/Window state

Parameter Number

Parameter Size

Parameter Name

Parameter Values

12 1 Auto Report Illumination Time 1 to 127
(Default)
Auto Report Illumination Time
  0 Disable automatic illumination reporting interval

Parameter Number

Parameter Size

Parameter Name

Parameter Values

13 1 Auto Report Temperature Time 1 to 127
(Default)
Auto Report Temperature Time
  0 Turn Off Automatic Interval Temperature Reporting

Parameter Number

Parameter Size

Parameter Name

Parameter Values

2 1 Basic Set Level 0 Send Basic Set Off
  -1 Send Basic Set On
  1 to 99 Send Basic Set Level between 1 and 99

Parameter Number

Parameter Size

Parameter Name

Parameter Values

20 1 Auto Report Tick Interval 1 to 127
(Default)
Auto Report Tick Interval
  0 Turn Off Automatic Reporting

Parameter Number

Parameter Size

Parameter Name

Parameter Values

21 1 Temperature Differential Report 1 to 127
(Default)
Temperature Differential Report
  0 Disable Temperature Differential Reporting

Parameter Number

Parameter Size

Parameter Name

Parameter Values

22 1 Illumination Differential Report 1 to 99 Illumination Differential Report
  0
(Default)
Turn Off Automatic Differential Illumination Reporting

Parameter Number

Parameter Size

Parameter Name

Parameter Values

4 1 Light Threshold 1 to 99
(Default)
Light Threshold Setting
  0 Turn Off Illumination Detection - Will not turn on the light.
  100 Turn Off Illumination Detection - The light is always turned on.

Parameter Number

Parameter Size

Parameter Name

Parameter Values

5 1 Operation Mode 0 to 1
(Default)
Reserved
  2 Bit Mask - When 1, Test Mode is Enabled, When 0, Test Mode is Disabled
  4 Bit Mask - When 1, Door/Window function is Disabled, When 0, Door/Window function is Enabled
  8 Bit Mask - When 1, Temperature Scale is Celsius, When 0, Temperature Scale is Fahrenheit
  16 Bit Mask - When 1, Illumination Report after event trigger is not sent, When 0, illumination report after trigger is sent.
  32 Bit Mask - When 1, Temperature report after trigger is not sent, When 0, temperature report after trigger is sent.
  64 Reserved
  -128 Bit Mask - When 1, Back key release into test mode is disabled, when 0, back key into test mode is enabled.

Parameter Number

Parameter Size

Parameter Name

Parameter Values

6 1 Mult-Sensor Function Switch 0 to 1 Bit Mask, When 1, Door opening will not send a signal to the nodes in association group 2, When 0, door opening will cause the lights in association group 2 to be sent a control signal.
  2 to 15
(Default)
Reserved
  16 Bit Mask, When 1, Disable the 5 second delay before turning off the light when the door is closed, When 0, enable a 5 second delay before turning off the light when the door is closed.
  32 Bit Mask, When 1, the automatic turn-off of the light after the light is turned on by a door opening, When 0, the light that is turned on by the door opening will be automatically turned off
  64 to -128 Reserved.

Parameter Number

Parameter Size

Parameter Name

Parameter Values

7 1 Customer Function 0 to 7
(Default)
Reserved
  8 Bit Mask, When 1, BASIC SET OFF is not sent when the door is closed, When 0, BASIC SET OFF is sent when the door is closed.
  16 Bit Mask, When 1, Door Opening is reported using Sensor Binary, When 0, Door Opening is reported using Notification Report
  32 Bit Mask, When 1, Multi CC is Disabled, When 0, Multi CC is Enabled
  64 Bit Mask, When 1, the battery state is not sent when the device is triggered, when 0, the battery state is sent when the device is triggered.
  -128 Reserved

Parameter Number

Parameter Size

Parameter Name

Parameter Values

9 1 Turn Off Light Time 1 to 127
(Default)
Turn Off Light Time (Multiplied by 8)
  0 Disable automatic light turn off