There are over 4297 interoperable
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
10 | 1 | Auto Report Battery Time | 1 to 127 (Default) |
Auto Report Battery Time | |
0 | Turn Off Automatic Interval Battery Reporting | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
11 | 1 | Auto Report Door/Window State Time | 1 to 127 (Default) |
Auto Report Door/Window State Time | |
0 | Disable automatic interval reporting of the Door/Window state | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
12 | 1 | Auto Report Illumination Time | 1 to 127 (Default) |
Auto Report Illumination Time | |
0 | Disable automatic illumination reporting interval | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
13 | 1 | Auto Report Temperature Time | 1 to 127 (Default) |
Auto Report Temperature Time | |
0 | Turn Off Automatic Interval Temperature Reporting | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
2 | 1 | Basic Set Level | 0 | Send Basic Set Off | |
-1 | Send Basic Set On | ||||
1 to 99 | Send Basic Set Level between 1 and 99 | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
20 | 1 | Auto Report Tick Interval | 1 to 127 (Default) |
Auto Report Tick Interval | |
0 | Turn Off Automatic Reporting | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
21 | 1 | Temperature Differential Report | 1 to 127 (Default) |
Temperature Differential Report | |
0 | Disable Temperature Differential Reporting | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
22 | 1 | Illumination Differential Report | 1 to 99 | Illumination Differential Report | |
0 (Default) |
Turn Off Automatic Differential Illumination Reporting | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
4 | 1 | Light Threshold | 1 to 99 (Default) |
Light Threshold Setting | |
0 | Turn Off Illumination Detection - Will not turn on the light. | ||||
100 | Turn Off Illumination Detection - The light is always turned on. | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
5 | 1 | Operation Mode | 0 to 1 (Default) |
Reserved | |
2 | Bit Mask - When 1, Test Mode is Enabled, When 0, Test Mode is Disabled | ||||
4 | Bit Mask - When 1, Door/Window function is Disabled, When 0, Door/Window function is Enabled | ||||
8 | Bit Mask - When 1, Temperature Scale is Celsius, When 0, Temperature Scale is Fahrenheit | ||||
16 | Bit Mask - When 1, Illumination Report after event trigger is not sent, When 0, illumination report after trigger is sent. | ||||
32 | Bit Mask - When 1, Temperature report after trigger is not sent, When 0, temperature report after trigger is sent. | ||||
64 | Reserved | ||||
-128 | Bit Mask - When 1, Back key release into test mode is disabled, when 0, back key into test mode is enabled. | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
6 | 1 | Mult-Sensor Function Switch | 0 to 1 | Bit Mask, When 1, Door opening will not send a signal to the nodes in association group 2, When 0, door opening will cause the lights in association group 2 to be sent a control signal. | |
2 to 15 (Default) |
Reserved | ||||
16 | Bit Mask, When 1, Disable the 5 second delay before turning off the light when the door is closed, When 0, enable a 5 second delay before turning off the light when the door is closed. | ||||
32 | Bit Mask, When 1, the automatic turn-off of the light after the light is turned on by a door opening, When 0, the light that is turned on by the door opening will be automatically turned off | ||||
64 to -128 | Reserved. | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
7 | 1 | Customer Function | 0 to 7 (Default) |
Reserved | |
8 | Bit Mask, When 1, BASIC SET OFF is not sent when the door is closed, When 0, BASIC SET OFF is sent when the door is closed. | ||||
16 | Bit Mask, When 1, Door Opening is reported using Sensor Binary, When 0, Door Opening is reported using Notification Report | ||||
32 | Bit Mask, When 1, Multi CC is Disabled, When 0, Multi CC is Enabled | ||||
64 | Bit Mask, When 1, the battery state is not sent when the device is triggered, when 0, the battery state is sent when the device is triggered. | ||||
-128 | Reserved | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
9 | 1 | Turn Off Light Time | 1 to 127 (Default) |
Turn Off Light Time (Multiplied by 8) | |
0 | Disable automatic light turn off | ||||