Z-Wave Products

TThere are thousands of interoperable Z-Wave products throughout the world, and over 94 million Z-Wave products have been sold since our beginnings in 2001. All of them work together regardless of brand, because they're all based on the common Z - Wavestandard.Browse our Product Finder to see what Z -Wave can do for you.

Z-Wave Configuration Capabilities

Model: Motion Sensor (MT02647)

Z-Wave Certification Number: ZC10-14090010


Parameter Number

Parameter Size

Parameter Name

Parameter Values

10 1 Auto Report Battery Time 0 to 127
(Default)
Auto Report Battery Time

Parameter Number

Parameter Size

Parameter Name

Parameter Values

12 1 Auto Report Illumination Time 0 to 127
(Default)
Auto Report Illumination Time

Parameter Number

Parameter Size

Parameter Name

Parameter Values

13 1 Auto Report Temperature Time 0 to 127
(Default)
Auto Report Temperature Time

Parameter Number

Parameter Size

Parameter Name

Parameter Values

2 1 Basic Set Level 0 to 255
(Default)
Basic Set Value

Parameter Number

Parameter Size

Parameter Name

Parameter Values

20 1 Auto Report Tick Interval 0 to 255
(Default)
Auto Report Tick Interval

Parameter Number

Parameter Size

Parameter Name

Parameter Values

21 1 Temperature Differential Report 0 to 127
(Default)
Temperature Differential Report

Parameter Number

Parameter Size

Parameter Name

Parameter Values

22 1 Illumination Differential Report 0 to 99
(Default)
Illumination Differential Report

Parameter Number

Parameter Size

Parameter Name

Parameter Values

3 1 PIR Sensitivity 0 to 99
(Default)
PIR Level

Parameter Number

Parameter Size

Parameter Name

Parameter Values

4 1 Light Threshold 0 to 100
(Default)
Light Threshold

Parameter Number

Parameter Size

Parameter Name

Parameter Values

5 1 Operation Mode 2 Bit1: 1 means test mode, 0 means normal mode. Notice: This bit only effect by the DIP Switch setting to “customer mode”, otherwise it decides by DIP Switch setting to Test or Normal Mode.
  8 Setting the temperature scale.0: Fahrenheit, 1:Celsius
  16 Disable the illumination report after event triggered. (1:Disable, 0:Enable)
  32 Disable the temperature report after event triggered. (1:Disable, 0:Enable)
  -128 Disable the back key release into test mode. (1:Disable, 0:Enable) Notice: The reserve bit is allowed any value, but no effect.

Parameter Number

Parameter Size

Parameter Name

Parameter Values

6 1 Mult-Sensor Function Switch 2 Disable PIR integrate Illumination to turn ON the lighting nodes in the association group 2. (1:Disable, 0:Enable)

Parameter Number

Parameter Size

Parameter Name

Parameter Values

7 1 Customer Function 2 Enable sending motion OFF report. (0:Disable, 1:Enable) Note: Depends on the Bit4, 0: Report Notification CC, Type: 0x07, Event: 0xFE 1: Sensor Binary Report, Type: 0x0C, Value: 0x00
  4
(Default)
Enable PIR super sensitivity mode. (0:Disable, 1:Enable)
  16 Notification Type, 0: Using Notification Report. 1: Using Sensor Binary Report.
  32 Disable Multi CC in auto report. (1:Disable, 0:Enable)
  64 Disable to report battery state when the device triggered. (1:Disable, 0:Enable)

Parameter Number

Parameter Size

Parameter Name

Parameter Values

8 1 PIR Re-Detect Interval Time 1 to 127
(Default)
PIR Re-Detect Interval Time

Parameter Number

Parameter Size

Parameter Name

Parameter Values

9 1 Turn Off Light Time 0 to 127
(Default)
Turn Off Light Time