Z-Wave Products

There are over 4407 interoperable Z-Wave products throughout the world, and over 94 million Z-Wave products have been sold since our beginnings in 2001. All of them work together regardless of brand, because they're all based on the common Z - Wavestandard.Browse our Product Finder to see what Z -Wave can do for you.

Z-Wave Configuration Capabilities

Model: Scene Switch (MT2652)

Z-Wave Certification Number: ZC10-14090021


Parameter Number

Parameter Size

Parameter Name

Parameter Values

1 1 Button 1 and 3 pair mode 2 In pair with double clicks
  0 seperately
  1
(Default)
In pair without double clicks

Parameter Number

Parameter Size

Parameter Name

Parameter Values

11 1 Command to Control Group A 5 Send Preconfigured Scenes
  7 Control DoorLock
  8
(Default)
Central Scene to Gateway
  0 Disabled
  1 Switch On/Off and Dim (send Basic Set and Switch Multilevel)
  2 Switch On/Off only (send Basic Set)
  3 Switch All
  4 Send Scenes

Parameter Number

Parameter Size

Parameter Name

Parameter Values

12 1 Command to Control Group B 4 Send Scenes
  3 Switch All
  5 Send Preconfigured Scenes
  7 Control DoorLock
  8
(Default)
Central Scene to Gateway
  0 Disabled
  1 Switch On/Off and Dim (send Basic Set and Switch Multilevel)
  2 Switch On/Off only (send Basic Set)

Parameter Number

Parameter Size

Parameter Name

Parameter Values

13 1 Command to Control Group C 0 Disabled
  1 Switch On/Off and Dim (send Basic Set and Switch Multilevel)
  2 Switch On/Off only (send Basic Set)
  3 Switch All
  4 Send Scenes
  5 Send Preconfigured Scenes
  7 Control DoorLock
  8
(Default)
Central Scene to Gateway

Parameter Number

Parameter Size

Parameter Name

Parameter Values

14 1 Command to Control Group D 1 Switch On/Off and Dim (send Basic Set and Switch Multilevel)
  0 Disabled
  2 Switch On/Off only (send Basic Set)
  3 Switch All
  4 Send Scenes
  5 Send Preconfigured Scenes
  7 Control DoorLock
  8
(Default)
Central Scene to Gateway

Parameter Number

Parameter Size

Parameter Name

Parameter Values

2 1 Button 2 and 4 pair mode 2 In pair with double clicks
  1
(Default)
In pair without double clicks
  0 seperately

Parameter Number

Parameter Size

Parameter Name

Parameter Values

21 1 Send the following Switch All commands 1
(Default)
Switch off only
  2 Switch on only
  255 Switch all on and off

Parameter Number

Parameter Size

Parameter Name

Parameter Values

22 1 Invert buttons 1 Yes
  0
(Default)
No

Parameter Number

Parameter Size

Parameter Name

Parameter Values

25 1 Blocks wakeup even when wakeup interval is set 0 Wakeup is blocked
  1
(Default)
Wakeup is not blocked

Parameter Number

Parameter Size

Parameter Name

Parameter Values

30 1 Send unsolicited Battery Report on Wake Up 0
(Default)
No
  1 To same node as wake up notification
  2 Broadcast