Z-Wave Products

TThere are thousands of interoperable Z-Wave products throughout the world, and over 94 million Z-Wave products have been sold since our beginnings in 2001. All of them work together regardless of brand, because they're all based on the common Z - Wavestandard.Browse our Product Finder to see what Z -Wave can do for you.

Z-Wave Configuration Capabilities

Model: FIBARO Motion Sensor (FGMS-001)

Z-Wave Certification Number: ZC10-15050019


Parameter Number

Parameter Size

Parameter Name

Parameter Values

1 2 MOTION SENSOR’S SENSITIVITY 8 to 255
(Default)

Parameter Number

Parameter Size

Parameter Name

Parameter Values

12 1 BASIC COMMAND CLASS FRAMES CONFIGURATION 1 only the BASIC ON command frame sent in Basic Command Class.
  2 only the BASIC OFF command frame sent in Basic Command Class.
  0
(Default)
BASIC ON and OFF command frames sent in Basic Command Class.

Parameter Number

Parameter Size

Parameter Name

Parameter Values

14 2 BASIC ON command frame value 0 to 255
(Default)

Parameter Number

Parameter Size

Parameter Name

Parameter Values

16 2 BASIC OFF command frame value 0 to 255
(Default)

Parameter Number

Parameter Size

Parameter Name

Parameter Values

18 1 ASSOCIATIONS IN Z-WAVE NETWORK SECURITY MODE 0 to 15
(Default)

Parameter Number

Parameter Size

Parameter Name

Parameter Values

2 1 MOTION SENSOR’S BLIND TIME (INSENSITIVITY) 0 to 15
(Default)
(0,5-8 seconds) Formula to calculate the time: time [s] = 0.5 x (value + 1)

Parameter Number

Parameter Size

Parameter Name

Parameter Values

20 1 TAMPER SENSITIVITY 0 to 121
(Default)
(0,08 - 2g; multiply by 0,016g; 0 = tamper inactive)

Parameter Number

Parameter Size

Parameter Name

Parameter Values

22 2 TAMPER ALARM CANCELLATION DELAY 1 to 32767
(Default)
(1-32767 seconds)

Parameter Number

Parameter Size

Parameter Name

Parameter Values

24 1 TAMPER OPERATING MODES 2 Tamper and orientation in space. Three reports are sent right after tamper alarm cancellation delay time.
  0
(Default)
Only tamper (default)
  1 Tamper and earthquake detector. Function may be used as a simple seismograph. Two reports including the strength of shock are always sent. First, right after the detection and second (value=0) after tamper alarm cancellation delay time.

Parameter Number

Parameter Size

Parameter Name

Parameter Values

25 1 TAMPER CANCELLATION REPORTS 1
(Default)
Send tamper cancellation report
  0 Do not send tamper cancellation report

Parameter Number

Parameter Size

Parameter Name

Parameter Values

28 1 TAMPER ALARM BROADCAST MODE 0
(Default)
Tamper alarm reported to association groups.
  1 Tamper alarm reported in broadcast mode to 3rd association group.

Parameter Number

Parameter Size

Parameter Name

Parameter Values

29 1 TAMPER ALARM BROADCAST MODE 0
(Default)
Tamper alarm reported to association groups.
  1 Tamper alarm reported in broadcast mode to 5th association group.

Parameter Number

Parameter Size

Parameter Name

Parameter Values

3 1 PIR sensor’s “PULSE COUNTER” 0 to 3
(Default)
(1 - 4 pulses) Formula to calculate the number of pulses: pulses = (value + 1)

Parameter Number

Parameter Size

Parameter Name

Parameter Values

4 1 PIR sensor’s “WINDOW TIME” 0 to 3
(Default)
Formula to calculate the time: time [s] = 4 x (value + 1)

Parameter Number

Parameter Size

Parameter Name

Parameter Values

40 2 ILLUMINATION REPORT THRESHOLD 0 to 32767
(Default)
(1-32767 lux; 0=reports are not sent)

Parameter Number

Parameter Size

Parameter Name

Parameter Values

42 2 ILLUMINATION REPORTS INTERVAL 0 to 32767
(Default)
(1-32767 seconds; 0 = no reports)

Parameter Number

Parameter Size

Parameter Name

Parameter Values

6 2 MOTION ALARM CANCELLATION DELAY 1 to 32767
(Default)
(1-32767 seconds)

Parameter Number

Parameter Size

Parameter Name

Parameter Values

60 2 TEMPERATURE REPORT THRESHOLD 0 to 225
(Default)
(0,1-25,5[C],; 0 = reports are not sent)

Parameter Number

Parameter Size

Parameter Name

Parameter Values

62 2 INTERVAL OF TEMPERATURE MEASURING 0 to 32767
(Default)
(1 - 32767 seconds; 0 = temperature will not be measured)

Parameter Number

Parameter Size

Parameter Name

Parameter Values

64 2 TEMPERATURE REPORTS INTERVAL 0 to 32767
(Default)
(1 - 32767 seconds; 0 = no reports)

Parameter Number

Parameter Size

Parameter Name

Parameter Values

66 2 TEMPERATURE OFFSET -1000 to 1000
(Default)
(-100[C] – 100[C])

Parameter Number

Parameter Size

Parameter Name

Parameter Values

8 1 PIR SENSOR OPERATING MODE 0
(Default)
PIR sensor always active
  1 PIR sensor active during the day only
  2 PIR sensor active during the night only

Parameter Number

Parameter Size

Parameter Name

Parameter Values

80 1 LED SIGNALING MODE 1 to 9 single long blink at the moment of reporting motion. No other motion will be indicated until alarm is cancelled.
  10 to 18
(Default)
single long blink at the moment of reporting motion and one short blink each time the motion is detected again.
  19 to 26 single long blink at the moment of reporting motion and two short blinks each time the motion is detected again.

Parameter Number

Parameter Size

Parameter Name

Parameter Values

81 1 LED BRIGHTNESS 0 to 100
(Default)
(1 - 100%; 0 = brightness determined by the ambient lighting - see parameters 82 and 83)

Parameter Number

Parameter Size

Parameter Name

Parameter Values

82 2 AMBIENT ILLUMINATION LEVEL BELOW WHICH LED BRIGHTNESS IS SET TO 1% 0 to 32766
(Default)
(0-32766 lux)

Parameter Number

Parameter Size

Parameter Name

Parameter Values

83 2 AMBIENT ILLUMINATION LEVEL ABOVE WHICH LED BRIGHTNESS IS SET TO 100% 1 to 32767
(Default)
(1-32767 lux)

Parameter Number

Parameter Size

Parameter Name

Parameter Values

86 2 MINIMUM TEMPERATURE RESULTING IN BLUE LED ILLUMINATION 0 to 255
(Default)
(0-255[C])

Parameter Number

Parameter Size

Parameter Name

Parameter Values

87 2 MAXIMUM TEMPERATURE RESULTING IN RED LED ILLUMINATION 0 to 255
(Default)
(0-255[C])

Parameter Number

Parameter Size

Parameter Name

Parameter Values

89 1 LED INDICATING TAMPER ALARM 0 LED does not indicate tamper alarm.
  1
(Default)
LED indicates tamper alarm.

Parameter Number

Parameter Size

Parameter Name

Parameter Values

9 2 NIGHT / DAY 1 to 32767
(Default)
(1-32767 lux)