Z-Wave Products

There are over 4377 interoperable Z-Wave products throughout the world, and over 94 million Z-Wave products have been sold since our beginnings in 2001. All of them work together regardless of brand, because they're all based on the common Z - Wavestandard.Browse our Product Finder to see what Z -Wave can do for you.

Z-Wave Configuration Capabilities

Model: MultiSensor Gen5 (ZW074-B)

Z-Wave Certification Number: ZC10-14120005


Parameter Number

Parameter Size

Parameter Name

Parameter Values

101 4 Which report needs to be sent in Report group 1 64 The humidity sensor report is selected.
  128 The light sensor report is selected.
  1 The battery report is selected.
  32 The temperature sensor report is selected.

Parameter Number

Parameter Size

Parameter Name

Parameter Values

102 4 Which report needs to be sent in Report group 2. 128 The light sensor report is selected.
  1 The battery report is selected.
  32 The temperature sensor report is selected.
  64 The humidity sensor report is selected.

Parameter Number

Parameter Size

Parameter Name

Parameter Values

103 4 Which report needs to be sent in Report group 3. 32 The temperature sensor report is selected.
  64 The humidity sensor report is selected.
  128 The light sensor report is selected.
  1 The battery report is selected.

Parameter Number

Parameter Size

Parameter Name

Parameter Values

111 4 The interval time of sending reports in Report group 1 5 to 2678400
(Default)
The range of interval time is 5 to 2678400.

Parameter Number

Parameter Size

Parameter Name

Parameter Values

112 4 The interval time of sending reports in Report group 2. 5 to 2678400
(Default)
The range of interval time is 5 to 2678400.

Parameter Number

Parameter Size

Parameter Name

Parameter Values

113 4 The interval time of sending reports in Report group 3 5 to 2678400
(Default)
The range of interval time is 5 to 2678400.

Parameter Number

Parameter Size

Parameter Name

Parameter Values

2 1 Enable/Disable waking up for 10 minutes when re-power on (battery mode) the MultiSensor. 0
(Default)
Disable waking up for 10 minutes when re-power on (battery mode) the MultiSensor.
  1 Enable waking up for 10 minutes when re-power on (battery mode) the MultiSensor.

Parameter Number

Parameter Size

Parameter Name

Parameter Values

252 1 Enable/disable all configuration parameters to be locked 0
(Default)
Disable all configuration parameters to be locked.
  1 Enable all configuration parameters to be locked.

Parameter Number

Parameter Size

Parameter Name

Parameter Values

255 4 Reset to default factory setting 1 Resets all configuration parameters to default setting.
  1431655765 Reset the product to default factory setting and be excluded from the Z-wave network.

Parameter Number

Parameter Size

Parameter Name

Parameter Values

3 2 Timeout of the motion sensor 1 to 255
(Default)
The unit of timeout is second.
  256 to 15300 The unit of timeout is minute.

Parameter Number

Parameter Size

Parameter Name

Parameter Values

4 1 Enable/disable the function of motion sensor. 0
(Default)
Disable the function of motion sensor.
  1 Enable the function of motion sensor.

Parameter Number

Parameter Size

Parameter Name

Parameter Values

40 1 Enable/disable the selective reporting only when measurements reach a certain threshold or percentage set in 41-44 below. 1 Enable the selective reporting.
  0
(Default)
Disable the selective reporting.

Parameter Number

Parameter Size

Parameter Name

Parameter Values

41 2 Threshold change in temperature to induce an automatic report. 0 to 65535
(Default)
Threshold of temperature.

Parameter Number

Parameter Size

Parameter Name

Parameter Values

42 2 Threshold change in humidity to induce an automatic report. 0 to 100
(Default)
Threshold of humidity

Parameter Number

Parameter Size

Parameter Name

Parameter Values

43 2 Threshold change in luminance to induce an automatic report. 0 to 1000
(Default)
Threshold of luminance

Parameter Number

Parameter Size

Parameter Name

Parameter Values

44 2 Threshold change in battery level to induce an automatic report. 0 to 100
(Default)
Threshold of battery level.

Parameter Number

Parameter Size

Parameter Name

Parameter Values

46 1 Enable/disable to send the alarm report of low temperature 0
(Default)
Disable to send the alarm report of low temperature(<-15℃)
  1 Enable to send the alarm report of low temperature(<-15℃)

Parameter Number

Parameter Size

Parameter Name

Parameter Values

5 1 Which command would be sent when the motion sensor triggered. 2 Send Sensor Binary Report CC.
  1
(Default)
Send Basic Set CC.