TThere are thousands of interoperable
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
1 | 1 | Which value of the Sensor Binary Report will be sent when the magnet switch to open/close. | 0 (Default) |
When the magnet switch to open, Sensor Binary Report=0xFF. When the magnet switch to close, Sensor Binary Report=0x00. | |
1 | When the magnet switch to open, Sensor Binary Report=0x00. When the magnet switch to close, Sensor Binary Report=0xFF. | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
101 | 1 | Enable/disable the function of low battery checking | 0 (Default) |
Disable low battery checking. | |
1 | Enable low battery checking. | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
111 | 4 | The interval time of low battery checking. | 0 to 2147483647 (Default) |
The range of interval time is 0 to 2147483647. | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
121 | 4 | To set which command will be sent to the associated nodes when the magnet switch is triggered. | 16 | Send Sensor Binary Report to associated nodes when magnet switch is triggered. | |
256 (Default) |
Send Basic Set to associated nodes when magnet switch is triggered. | ||||
272 | Send the Sensor Binary Report and Basic Set to associated nodes when magnet switch is triggered. | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
252 | 1 | Enable/disable all configuration parameters to be locked | 0 (Default) |
Disable all configuration parameters to be locked. | |
1 | Enable all configuration parameters to be locked. | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
254 | 2 | Device Tag | 0 to 65535 (Default) |
The range of device tag is 65535. | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
3 | 1 | Which value of the Basic Set will be sent when the magnet switch to open/close. | 0 (Default) |
When the magnet switch to open, Basic Set=0xFF. When the magnet switch to close, Basic Set=0x00. | |
1 | When the magnet switch to open, Basic Set=0x00. When the magnet switch to close, Basic Set=0xFF. | ||||