Z-Wave Products

There are over 4158 interoperable Z-Wave products throughout the world, and over 94 million Z-Wave products have been sold since our beginnings in 2001. All of them work together regardless of brand, because they're all based on the common Z - Wavestandard.Browse our Product Finder to see what Z -Wave can do for you.

Z-Wave Configuration Capabilities

Model: In Wall Dual relay(1 way) switch module (PAN06-1A)

Z-Wave Certification Number: ZC10-14120009


Parameter Number

Parameter Size

Parameter Name

Parameter Values

1 1 Selected Relay 1 Select relay1 : Only relay1 can be controlled and report.
  2 Select relay2 : Only relay2 can be controlled and report.
  3
(Default)
Select relay1 & relay2 :Relay1 and relay2 can be controlled and report at the same time.

Parameter Number

Parameter Size

Parameter Name

Parameter Values

2 1 Edge / Pulse / Edge-Toggle mode 1
(Default)
Edge mode: this mode is suitable for the bi stable wall switch that has indicator point on the switch, and the same position correspond to same state of relay1 and relay2. if the PAN06 relay change the state because of receiving Z-Wave RF command, it may need two times of change (switch on to off or switch off to on) to let relay back to the correspond state.
  2 Pulse mode: this mode is suitable for the toggle type wall switch to swap the state of Relay1 or Relay2.
  3 Edge-Toggle mode: this mode is suitable for the normal bi-stable switch, every time when change the state of the wall switch will also swap the state of Relay1 or Relay2

Parameter Number

Parameter Size

Parameter Name

Parameter Values

3 1 Restore switch state mode 0 SWITCH OFF
  1
(Default)
LAST SWITCH STATE
  2 SWITCH ON

Parameter Number

Parameter Size

Parameter Name

Parameter Values

4 2 Auto off timer 0
(Default)
Disable auto off function
  1 to 32767 1s ~ 32767s

Parameter Number

Parameter Size

Parameter Name

Parameter Values

5 1 RF off command mode 0
(Default)
Switch Off : It switches to OFF state. The default setting is Switch Off.
  1 Ignore : The switch off command will be ignored.
  2 Switch Toggle : It switches to the inverse of current state.
  3 Switch On : It switches to ON state.

Parameter Number

Parameter Size

Parameter Name

Parameter Values

6 1 Existence of Endpoint3 1
(Default)
Endpoint3 exist
  2 No Endpoint3