TThere are thousands of interoperable
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
1 | 1 | Basic Set OFF Level | 0 (Default) |
Setting the BASIC command value 0x00. | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
10 | 1 | Auto Report Battery Time | 0 to 127 (Default) |
The interval time for auto report the battery level. | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
13 | 1 | Auto Report Temperature Time | 0 to 127 (Default) |
The interval time for auto report the temperature. | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
14 | 1 | Auto Report Humidity Time | 0 to 127 (Default) |
The interval time for auto report the humidity. | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
15 | 1 | Auto Report Flood Time | 0 to 127 (Default) |
The interval time for auto report the flood state. | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
2 | 1 | Basic Set ON Level | 255 (Default) |
Setting the BASIC command value 0xFF. | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
20 | 1 | Auto Report Tick Interval | 0 to 255 (Default) |
The interval time for auto report each tick. | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
21 | 1 | Temperature Differential Report | 0 to 127 (Default) |
The temperature differential to report. 0 means turn off this function. | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
23 | 1 | Humidity Differential Report | 0 to 60 (Default) |
The humidity differential to report. | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
5 | 1 | Operation Mode | 1 | Disable the Flood function. | |
8 | Setting the temperature scale. 0: Fahrenheit, 1:Celsius | ||||
32 | Disable the temperature report after event triggered. (1:Disable, 0:Enable) | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
6 | 1 | Mult-Sensor Function Switch | 64 | Disable the humidity report after event triggered. (1:Disable, 0:Enable) | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
7 | 1 | Customer Function | 8 | Disable send out BASIC OFF after the flood event cleared. (1:Disable, 0:Enable) | |
16 | Notification Type, 0: Using Notification Report. 1: Using Sensor Binary Report. | ||||
32 | Disable Multi CC in auto report. (1:Disable, 0:Enable) | ||||
64 | Disable to report battery state when the device triggered. (1:Disable, 0:Enable) | ||||