Z-Wave Products

TThere are thousands of interoperable Z-Wave products throughout the world, and over 94 million Z-Wave products have been sold since our beginnings in 2001. All of them work together regardless of brand, because they're all based on the common Z - Wavestandard.Browse our Product Finder to see what Z -Wave can do for you.

Z-Wave Configuration Capabilities

Model: Flood Multisensor (PAT02-1A)

Z-Wave Certification Number: ZC10-15010001


Parameter Number

Parameter Size

Parameter Name

Parameter Values

1 1 Basic Set OFF Level 0
(Default)
Setting the BASIC command value 0x00.

Parameter Number

Parameter Size

Parameter Name

Parameter Values

10 1 Auto Report Battery Time 0 to 127
(Default)
The interval time for auto report the battery level.

Parameter Number

Parameter Size

Parameter Name

Parameter Values

13 1 Auto Report Temperature Time 0 to 127
(Default)
The interval time for auto report the temperature.

Parameter Number

Parameter Size

Parameter Name

Parameter Values

14 1 Auto Report Humidity Time 0 to 127
(Default)
The interval time for auto report the humidity.

Parameter Number

Parameter Size

Parameter Name

Parameter Values

15 1 Auto Report Flood Time 0 to 127
(Default)
The interval time for auto report the flood state.

Parameter Number

Parameter Size

Parameter Name

Parameter Values

2 1 Basic Set ON Level 255
(Default)
Setting the BASIC command value 0xFF.

Parameter Number

Parameter Size

Parameter Name

Parameter Values

20 1 Auto Report Tick Interval 0 to 255
(Default)
The interval time for auto report each tick.

Parameter Number

Parameter Size

Parameter Name

Parameter Values

21 1 Temperature Differential Report 0 to 127
(Default)
The temperature differential to report. 0 means turn off this function.

Parameter Number

Parameter Size

Parameter Name

Parameter Values

23 1 Humidity Differential Report 0 to 60
(Default)
The humidity differential to report.

Parameter Number

Parameter Size

Parameter Name

Parameter Values

5 1 Operation Mode 1 Disable the Flood function.
  8 Setting the temperature scale. 0: Fahrenheit, 1:Celsius
  32 Disable the temperature report after event triggered. (1:Disable, 0:Enable)

Parameter Number

Parameter Size

Parameter Name

Parameter Values

6 1 Mult-Sensor Function Switch 64 Disable the humidity report after event triggered. (1:Disable, 0:Enable)

Parameter Number

Parameter Size

Parameter Name

Parameter Values

7 1 Customer Function 8 Disable send out BASIC OFF after the flood event cleared. (1:Disable, 0:Enable)
  16 Notification Type, 0: Using Notification Report. 1: Using Sensor Binary Report.
  32 Disable Multi CC in auto report. (1:Disable, 0:Enable)
  64 Disable to report battery state when the device triggered. (1:Disable, 0:Enable)