There are over 4290 interoperable
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
1 | 1 | Switch Status delta based configuration | 0 to 1 (Default) |
||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
10 | 2 | Current time interval based | 0 to 65520 (Default) |
||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
11 | 2 | Power Factor time interval based | 0 to 65520 (Default) |
||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
12 | 2 | Active Power time interval based | 0 to 65520 (Default) |
||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
13 | 2 | Active Energy time interval based | 0 to 65520 (Default) |
||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
14 | 2 | Apparent Energy time interval based | 0 to 65520 (Default) |
||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
15 | 1 | Relay and LED configuration | 0 (Default) |
Relay status will not be retain over power cycle, and Relay status LED will lit when relay ON and relay status LED will off when relay OFF. | |
1 | Relay status will be retain over power cycle, and Relay status LED will lit when relay ON and relay status LED will off when relay OFF. | ||||
2 | Relay status will not be retain over power cycle, and Relay status LED will off when relay ON and relay status LED will lit when relay OFF. | ||||
3 | Relay status will be retain over power cycle, and Relay status LED will off when relay ON and relay status LED will lit when relay OFF. | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
16 | 1 | Sleep Current Configuration | 0 to 1000 (Default) |
||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
2 | 2 | Voltage delta based configuration | 0 to 600 (Default) |
||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
3 | 1 | Current delta based configuration | 0 to 1500 (Default) |
||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
4 | 2 | Power Factor delta based configuration | 0 to 1000 (Default) |
||
0 (Default) |
|||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
5 | 2 | Active Power delta based configuration | 0 to 4000 (Default) |
||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
6 | 2 | Active Energy delta based configuration | 0 to 32000 (Default) |
||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
7 | 2 | Apparent Energy delta based configuration | 0 to 32000 (Default) |
||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
8 | 2 | Switch Status time interval based | 0 to 65520 (Default) |
||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
9 | 2 | Voltage time interval based | 0 to 65520 (Default) |
||