There are over 4378 interoperable
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
1 | 1 | Device Status | 4 | IGNORE | |
3 | OFF | ||||
2 | ON | ||||
1 (Default) |
TOGGLE | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
20 | 1 | Device status upon receipt of a Basic Set command | 3 | IGNORE IF OFF | |
4 | IGNORE | ||||
1 | AS RECEIVED | ||||
2 | IGNORE IF ON | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
30 | 2 | Overcurrent level | 0 to 1250 (Default) |
Overcurren level in hundredths of Amperes | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
31 | 2 | Overcurrent time | 0 to 10800 (Default) |
Time in seconds | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
32 | 1 | Next State | 2 | OFF | |
0 (Default) |
IGNORE | ||||
3 | TOGGLE | ||||
1 | ON | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
33 | 4 | Meter Reset | 0 | RESET METER | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
34 | 1 | Energy flow | 1 (Default) |
Consumed | |
2 | Produced | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
35 | 2 | UP Power Level | 0 to 3000 (Default) |
UP Power level in Watt | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
36 | 2 | UP Power Time | 0 to 10800 (Default) |
UP Power Time in seconds | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
38 | 1 | UP Power Associated | 0 (Default) |
OFF | |
100 | ON | ||||
1 to 99 | Dimming | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
39 | 2 | DOWN Power Level | 0 to 11250 (Default) |
DOWN Power Level in Watt | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
40 | 2 | DOWN Power Time | 0 to 10800 (Default) |
DOWN Power Time in seconds | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
41 | 1 | DOWN Power State | 1 | ON | |
2 | OFF | ||||
3 | TOGGLE | ||||
0 (Default) |
IGNORE | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
42 | 1 | DOWN Power Associated | 1 to 99 | Dimming | |
0 (Default) |
OFF | ||||
255 | ON | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
43 | 4 | Energy Level | 0 to 2000000 (Default) |
Energy Level in KWh | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
44 | 1 | Energy Limit State | 0 (Default) |
IGNORE | |
1 | ON | ||||
2 | OFF | ||||
3 | TOGGLE | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
45 | 1 | Variation Instantaneous Power | 1 to 100 (Default) |
Power variation in percentage | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
46 | 1 | Report Time Frequency | 1 to 100 (Default) |
Time in minutes | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
48 | 2 | Nominal Voltage | 1100 to 2300 (Default) |
Nominal Voltage in Volt | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
49 | 1 | Fall in maximum voltage | 1 to 100 (Default) |
percentage of voltage variation | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
50 | 1 | Electric parameters subjected to automatic notification | 0 | Power | |
2 | Energy | ||||
4 | Voltage | ||||
8 | Current | ||||
16 | Power Factor | ||||
32 | Multilevel Sensor: Power Report | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
60 | 1 | Start-up status | 1 | ON | |
3 (Default) |
Status prior to restart | ||||
2 | OFF | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
61 | 1 | Configuration reset | 0 | FACTORY RESET | |
1 | ASSOCIATIONS RESET | ||||
2 | CONFIGURATIONS RESET | ||||
4 (Default) |
IGNORE | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
62 | 1 | Type of external switch | 0 | IGNORE | |
1 | BUTTON | ||||
4 (Default) |
AUTOMATIC RECOGNITION | ||||
2 | SWITCH | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
63 | 1 | Load control | 1 (Default) |
DIRECT CONTROL | |
3 | CONTROL BY MEANS OF A CONTACTOR WITH NORMALLY CLOSED COMMAND | ||||
4 | AS AN EXTERNAL INDICATOR | ||||
2 | CONTROL BY MEANS OF A CONTACTOR WITH NORMALLY OPEN COMMAND | ||||