TThere are thousands of interoperable
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
10 | 1 | Induce an automatic report of Channel 2. | 0 to 100 (Default) |
The threshold can be set from 0 to 100 percent. | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
101 | 4 | To set which report need to be sent. | 4 | Report Instantaneous Voltage of whole HEM. | |
8 | Report Instantaneous Current (Amperes) of whole HEM. | ||||
2 (Default) |
Report Instantaneous Watts of whole HEM. | ||||
1 | Report Accumulated kWh of whole HEM. | ||||
256 | Report Instantaneous Watts of Channel 1. | ||||
768 | Report Instantaneous Watts of Channel 2. | ||||
2048 | Report Accumulated kWh of Channel 1. | ||||
4096 | Report Accumulated kWh of Channel 2. | ||||
65536 | Report Instantaneous Voltage of Channel 1. | ||||
196608 | Report Instantaneous Voltage of Channel 2. | ||||
524288 | Report Instantaneous Current (Amperes) of Channel 1. | ||||
1048576 | Report Instantaneous Current (Amperes) of Channel 2. | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
102 | 4 | To set which report need to be sent. | 1 (Default) |
Report Accumulated kWh of whole HEM. | |
2 | Report Instantaneous Watts of whole HEM. | ||||
4 | Report Instantaneous Voltage of whole HEM. | ||||
8 | Report Instantaneous Current (Amperes) of whole HEM. | ||||
256 | Report Instantaneous Watts of Channel 1. | ||||
768 | Report Instantaneous Watts of Channel 2. | ||||
2048 | Report Accumulated kWh of Channel 1. | ||||
4096 | Report Accumulated kWh of Channel 2. | ||||
65536 | Report Instantaneous Voltage of Channel 1. | ||||
196608 | Report Instantaneous Voltage of Channel 2. | ||||
524288 | Report Instantaneous Current (Amperes) of Channel 1. | ||||
1048576 | Report Instantaneous Current (Amperes) of Channel 2. | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
103 | 4 | To set which report need to be sent. | 1 | Report Accumulated kWh of whole HEM. | |
2 | Report Instantaneous Watts of whole HEM. | ||||
4 | Report Instantaneous Voltage of whole HEM. | ||||
256 | Report Instantaneous Watts of Channel 1. | ||||
768 | Report Instantaneous Watts of Channel 2. | ||||
2048 | Report Accumulated kWh of Channel 1. | ||||
4096 | Report Accumulated kWh of Channel 2. | ||||
65536 | Report Instantaneous Voltage of Channel 1. | ||||
196608 | Report Instantaneous Voltage of Channel 2. | ||||
524288 | Report Instantaneous Current (Amperes) of Channel 1. | ||||
1048576 | Report Instantaneous Current (Amperes) of Channel 2. | ||||
8 | Report Instantaneous Current (Amperes) of whole HEM. | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
111 | 4 | Set the interval time of sending report. | 0 to 268435456 (Default) |
Interval Seconds | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
112 | 4 | Set the interval time of sending report. | 0 to 268435456 (Default) |
Interval Seconds | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
113 | 4 | Set the interval time of sending report. | 0 to 268435456 (Default) |
Interval Seconds | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
13 | 1 | Enable /disable CRC-16 Encapsulation. | 0 (Default) |
Disable CRC-16 Encapsulation. | |
1 | Enable CRC-16 Encapsulation. | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
2 | 1 | Energy detection mode configuration. | 1 | report positive/negative Wattage and the algebraic sum KWH value; | |
0 (Default) |
report Wattage and the absolute KWH value; | ||||
2 | report positive/negative Wattage and the positive KWH value (consuming electricity); | ||||
3 | report positive/negative Wattage and the negative KWH value (generating electricity). | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
200 | 1 | Partner ID | 0 (Default) |
Aeon Labs Standard Product | |
1 to 255 | Partner ID of Partner Product | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
252 | 1 | Enable/Disable Lock Configuration | 0 (Default) |
All configuration parameters are configurable. | |
1 | All configuration parameters are not configurable (Locked). | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
255 | 4 | Reset to default factory setting | 1431655765 | Reset the product to default factory setting and be excluded from the Z-wave network. | |
1 | Resets all configuration parameters to default setting. | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
3 | 1 | Enable/Disable the function of parameter 4 and 11. | 0 | Disable the function of parameter 4 and 11. | |
1 (Default) |
Enable the function of parameter 4 and 11. | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
4 | 2 | Induce a automatic report of whole HEM. | 0 to 32767 (Default) |
The threshold can be set from 0 to 32767 watt. | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
5 | 2 | Induce a automatic report of Channel 1. | 0 to 32767 (Default) |
The threshold can be set from 0 to 32767 watt. | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
6 | 2 | Induce an automatic report of Channel 2. | 0 to 32767 (Default) |
The threshold can be set from 0 to 32767 watt. | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
8 | 1 | Induce an automatic report of whole HEM. | 0 to 100 (Default) |
The threshold can be set from 0 to 100 percent. | |
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
9 | 1 | Induce an automatic report of Channel 1. | 0 to 100 (Default) |
The threshold can be set from 0 to 100 percent. | |