Z-Wave Products

TThere are thousands of interoperable Z-Wave products throughout the world, and over 94 million Z-Wave products have been sold since our beginnings in 2001. All of them work together regardless of brand, because they're all based on the common Z - Wavestandard.Browse our Product Finder to see what Z -Wave can do for you.

Z-Wave Configuration Capabilities

Model: Home Energy Meter Gen5 (ZW095-A)

Z-Wave Certification Number: ZC10-15040002


Parameter Number

Parameter Size

Parameter Name

Parameter Values

10 1 Induce an automatic report of Channel 2. 0 to 100
(Default)
The threshold can be set from 0 to 100 percent.

Parameter Number

Parameter Size

Parameter Name

Parameter Values

101 4 To set which report need to be sent. 4 Report Instantaneous Voltage of whole HEM.
  8 Report Instantaneous Current (Amperes) of whole HEM.
  2
(Default)
Report Instantaneous Watts of whole HEM.
  1 Report Accumulated kWh of whole HEM.
  256 Report Instantaneous Watts of Channel 1.
  768 Report Instantaneous Watts of Channel 2.
  2048 Report Accumulated kWh of Channel 1.
  4096 Report Accumulated kWh of Channel 2.
  65536 Report Instantaneous Voltage of Channel 1.
  196608 Report Instantaneous Voltage of Channel 2.
  524288 Report Instantaneous Current (Amperes) of Channel 1.
  1048576 Report Instantaneous Current (Amperes) of Channel 2.

Parameter Number

Parameter Size

Parameter Name

Parameter Values

102 4 To set which report need to be sent. 1
(Default)
Report Accumulated kWh of whole HEM.
  2 Report Instantaneous Watts of whole HEM.
  4 Report Instantaneous Voltage of whole HEM.
  8 Report Instantaneous Current (Amperes) of whole HEM.
  256 Report Instantaneous Watts of Channel 1.
  768 Report Instantaneous Watts of Channel 2.
  2048 Report Accumulated kWh of Channel 1.
  4096 Report Accumulated kWh of Channel 2.
  65536 Report Instantaneous Voltage of Channel 1.
  196608 Report Instantaneous Voltage of Channel 2.
  524288 Report Instantaneous Current (Amperes) of Channel 1.
  1048576 Report Instantaneous Current (Amperes) of Channel 2.

Parameter Number

Parameter Size

Parameter Name

Parameter Values

103 4 To set which report need to be sent. 1 Report Accumulated kWh of whole HEM.
  2 Report Instantaneous Watts of whole HEM.
  4 Report Instantaneous Voltage of whole HEM.
  256 Report Instantaneous Watts of Channel 1.
  768 Report Instantaneous Watts of Channel 2.
  2048 Report Accumulated kWh of Channel 1.
  4096 Report Accumulated kWh of Channel 2.
  65536 Report Instantaneous Voltage of Channel 1.
  196608 Report Instantaneous Voltage of Channel 2.
  524288 Report Instantaneous Current (Amperes) of Channel 1.
  1048576 Report Instantaneous Current (Amperes) of Channel 2.
  8 Report Instantaneous Current (Amperes) of whole HEM.

Parameter Number

Parameter Size

Parameter Name

Parameter Values

111 4 Set the interval time of sending report. 0 to 268435456
(Default)
Interval Seconds

Parameter Number

Parameter Size

Parameter Name

Parameter Values

112 4 Set the interval time of sending report. 0 to 268435456
(Default)
Interval Seconds

Parameter Number

Parameter Size

Parameter Name

Parameter Values

113 4 Set the interval time of sending report. 0 to 268435456
(Default)
Interval Seconds

Parameter Number

Parameter Size

Parameter Name

Parameter Values

13 1 Enable /disable CRC-16 Encapsulation. 0
(Default)
Disable CRC-16 Encapsulation.
  1 Enable CRC-16 Encapsulation.

Parameter Number

Parameter Size

Parameter Name

Parameter Values

2 1 Energy detection mode configuration. 1 report positive/negative Wattage and the algebraic sum KWH value;
  0
(Default)
report Wattage and the absolute KWH value;
  2 report positive/negative Wattage and the positive KWH value (consuming electricity);
  3 report positive/negative Wattage and the negative KWH value (generating electricity).

Parameter Number

Parameter Size

Parameter Name

Parameter Values

200 1 Partner ID 0
(Default)
Aeon Labs Standard Product
  1 to 255 Partner ID of Partner Product

Parameter Number

Parameter Size

Parameter Name

Parameter Values

252 1 Enable/Disable Lock Configuration 0
(Default)
All configuration parameters are configurable.
  1 All configuration parameters are not configurable (Locked).

Parameter Number

Parameter Size

Parameter Name

Parameter Values

255 4 Reset to default factory setting 1431655765 Reset the product to default factory setting and be excluded from the Z-wave network.
  1 Resets all configuration parameters to default setting.

Parameter Number

Parameter Size

Parameter Name

Parameter Values

3 1 Enable/Disable the function of parameter 4 and 11. 0 Disable the function of parameter 4 and 11.
  1
(Default)
Enable the function of parameter 4 and 11.

Parameter Number

Parameter Size

Parameter Name

Parameter Values

4 2 Induce a automatic report of whole HEM. 0 to 32767
(Default)
The threshold can be set from 0 to 32767 watt.

Parameter Number

Parameter Size

Parameter Name

Parameter Values

5 2 Induce a automatic report of Channel 1. 0 to 32767
(Default)
The threshold can be set from 0 to 32767 watt.

Parameter Number

Parameter Size

Parameter Name

Parameter Values

6 2 Induce an automatic report of Channel 2. 0 to 32767
(Default)
The threshold can be set from 0 to 32767 watt.

Parameter Number

Parameter Size

Parameter Name

Parameter Values

8 1 Induce an automatic report of whole HEM. 0 to 100
(Default)
The threshold can be set from 0 to 100 percent.

Parameter Number

Parameter Size

Parameter Name

Parameter Values

9 1 Induce an automatic report of Channel 1. 0 to 100
(Default)
The threshold can be set from 0 to 100 percent.