There are over 4392 interoperable
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
1 | 1 | Input 1 switch type | 0 | mono-stable switch type (push button) | |
1 (Default) |
bi-stable switch type | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
10 | 2 | Activate / deactivate functions ALL ON/ALL OFF | 255 (Default) |
ALL ON active, ALL OFF active | |
0 | ALL ON is not active ALL OFF is not active | ||||
1 | ALL ON is not active ALL OFF active | ||||
2 | ALL ON active ALL OFF is not active | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
100 | 1 | Enable / Disable Endpoint I2 or select Notification Type and Event | 1 (Default) |
Home Security; Motion Detection, unknown location | |
2 | Carbon Monoxide; Carbon Monoxide detected, unknown location. | ||||
3 | Carbon Dioxide; Carbon Dioxide detected, unknown location. | ||||
4 | Water Alarm; Water Leak detected, unknown location. | ||||
5 | Heat Alarm; Overheat detected, unknown location. | ||||
6 | Smoke Alarm; Smoke detected, unknown location. | ||||
0 | Endpoint, I2 disabled | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
11 | 2 | Automatic turning off output after set time | 0 (Default) |
Auto OFF disabled | |
1 to 32535 | 1 – 32535 = 1second (0,01s) – 32535 seconds (325,35s) Auto OFF enabled with define time, step is 1s or 10ms according to parameter nr.15 | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
110 | 2 | Temperature sensor offset settings | 32536 (Default) |
offset is 0.0C | |
1 to 100 | value from 0.1C to 10.0C is added to actual measured temperature. | ||||
1001 to 1100 | value from -0.1C to -10.0C is subtracted to actual measured temperature. | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
12 | 2 | Automatic turning on output after set time | 0 (Default) |
Auto ON disabled | |
1 to 32535 | 1 – 32535 = 1second (0,01s) – 32536 seconds (325,35s) Auto ON enabled with define time, step is 1s or 10ms according to parameter nr.15 | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
120 | 1 | Digital temperature sensor reporting | 0 | Reporting disabled | |
1 to 127 (Default) |
0,1C – 12,7C, step is 0,1C | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
15 | 1 | Automatic turning off / on seconds or milliseconds selection | 0 (Default) |
seconds selected | |
1 | milliseconds selected | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
2 | 1 | Input 2 contact type | 0 (Default) |
NO (normally open) input type | |
1 | 1 - NC (normally close) input type | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
30 | 1 | Saving the state of the relay after a power failure | 0 (Default) |
Flush 1D relay module saves its state before power failure (it returns to the last position saved before a power failure) | |
1 | Flush 1D relay module does not save the state after a power failure, it returns to "off" position. | ||||
Parameter Number |
Parameter Size |
Parameter Name |
Parameter Values |
||
63 | 1 | Output Switch selection | 0 (Default) |
When system is turned off the output is 0V (NC). | |
1 | When system is turned off the output is 230V or 24V (NO). | ||||