There are over 4392 interoperable Z-Wave products throughout the world, and over 94 million Z-Wave products have been sold since our beginnings in 2001. All of them work together regardless of brand, because they're all based on the common Z - Wavestandard.Browse our Product Finder to see what Z -Wave can do for you.

Z-Wave Configuration Capabilities

Model: Qubino Flush 1D relay (ZMNHN)

Z-Wave Certification Number: ZC10-15070017


Parameter Number

Parameter Size

Parameter Name

Parameter Values

1 1 Input 1 switch type 0 mono-stable switch type (push button)
  1
(Default)
bi-stable switch type

Parameter Number

Parameter Size

Parameter Name

Parameter Values

10 2 Activate / deactivate functions ALL ON/ALL OFF 255
(Default)
ALL ON active, ALL OFF active
  0 ALL ON is not active ALL OFF is not active
  1 ALL ON is not active ALL OFF active
  2 ALL ON active ALL OFF is not active

Parameter Number

Parameter Size

Parameter Name

Parameter Values

100 1 Enable / Disable Endpoint I2 or select Notification Type and Event 1
(Default)
Home Security; Motion Detection, unknown location
  2 Carbon Monoxide; Carbon Monoxide detected, unknown location.
  3 Carbon Dioxide; Carbon Dioxide detected, unknown location.
  4 Water Alarm; Water Leak detected, unknown location.
  5 Heat Alarm; Overheat detected, unknown location.
  6 Smoke Alarm; Smoke detected, unknown location.
  0 Endpoint, I2 disabled

Parameter Number

Parameter Size

Parameter Name

Parameter Values

11 2 Automatic turning off output after set time 0
(Default)
Auto OFF disabled
  1 to 32535 1 – 32535 = 1second (0,01s) – 32535 seconds (325,35s) Auto OFF enabled with define time, step is 1s or 10ms according to parameter nr.15

Parameter Number

Parameter Size

Parameter Name

Parameter Values

110 2 Temperature sensor offset settings 32536
(Default)
offset is 0.0C
  1 to 100 value from 0.1C to 10.0C is added to actual measured temperature.
  1001 to 1100 value from -0.1C to -10.0C is subtracted to actual measured temperature.

Parameter Number

Parameter Size

Parameter Name

Parameter Values

12 2 Automatic turning on output after set time 0
(Default)
Auto ON disabled
  1 to 32535 1 – 32535 = 1second (0,01s) – 32536 seconds (325,35s) Auto ON enabled with define time, step is 1s or 10ms according to parameter nr.15

Parameter Number

Parameter Size

Parameter Name

Parameter Values

120 1 Digital temperature sensor reporting 0 Reporting disabled
  1 to 127
(Default)
0,1C – 12,7C, step is 0,1C

Parameter Number

Parameter Size

Parameter Name

Parameter Values

15 1 Automatic turning off / on seconds or milliseconds selection 0
(Default)
seconds selected
  1 milliseconds selected

Parameter Number

Parameter Size

Parameter Name

Parameter Values

2 1 Input 2 contact type 0
(Default)
NO (normally open) input type
  1 1 - NC (normally close) input type

Parameter Number

Parameter Size

Parameter Name

Parameter Values

30 1 Saving the state of the relay after a power failure 0
(Default)
Flush 1D relay module saves its state before power failure (it returns to the last position saved before a power failure)
  1 Flush 1D relay module does not save the state after a power failure, it returns to "off" position.

Parameter Number

Parameter Size

Parameter Name

Parameter Values

63 1 Output Switch selection 0
(Default)
When system is turned off the output is 0V (NC).